video corpo

PL20
1Pages

{{requestButtons}}

Catalog excerpts

PL20 - 1

Electrical Data Nominal resistance kOhm 5 Independent linearity % of meas.range ±3 Angle tolerance (electrical) ° ±2 Temperature coefficient of the voltage divider ppm/°C 50 Recommended wiper current pA max. 1 Max. wiper current in case of malfunction mA 10 Min. life (electrical) movements 1 Mio. Mechanical Data Mechanical range ° 320 Angle tolerance (mechanical) ° ±2 Min. life (mechanical) movements 1 Mio. Draw out force of the shaft N / 1min min. 40 Draw out force of the wires N / 1min min. 50 Permitted torque for nut fixation Ncm max. 75 Standards Insulating resistance (500 VDC, 1bar, 2s) GOhm 8 Shock (half sine pulse, 7 ms) g 50 PL20 Applications • Readout potentiometer Features • Compact dimensions • Elevated torque • Protection class IP67 Options • Other nominal resistances • Special electrical angles • Without elevated torque Errors and omissions excepted. Subject to change without notice. / State: 05.05.20 Contelec AG Portstrasse 38 CH-2503 Biel/Bienne Phone +41 (0)32 3665600 Telefax +41 (0)32 3665604 sales@contelec.ch * The wires on customer side have to be sealed to fullfill the protection class of IP67. A company of the Siedle-Group