Group: Siedle-Group
Catalog excerpts
Electrical Data Nominal resistance Resistance tolerance Independent linearity Electrical travel Repeatability Temperature coefficient of the voltage divider Recommended wiper current Max. wiper current in case of malfunction Power rating P Min. life (electrical) Mechanical Data Mechanical travel Adjusting force of the push rod Adjusting force of the push rod with return spring Min. life (mechanical) Operating temperature Storage temperature Protection class Standards Insulating resistance (500 VDC, 1bar, 2s) Dielectric strength (VAC, 50Hz, 1min, 1bar) Vibration (Amax = 0.75mm, f = 30 ... 2000 Hz) Shock (half sine pulse, 7 ms) KL100 (KL10/KLR10) Applications • Gas pedal Features • Compact dimensions • Design flexibility • 5 Mio. cycles • Excellent linearity up to ±0.5% • Very good resolution, better 0,05mm Options • Linearity ±0.5 % • Nominal resistances between 1KOhm and 20KOhm • Pass trough push rod • Longer push rod • Connection by wires • Longer cable • Tandem-ganged • Without bushing • With bushing M6x0.75 or M10x0.75 • With or without return spring Errors and omissions excepted. Subject to change without notice. / State: 05.05.20 Contelec AG Portstrasse 38 CH-2503 Biel/Bienne Phone +41 (0)32 3665600 Telefax +41 (0)32 3665604 sales@contelec.ch conTelecA company of the Siedle-Group
Open the catalog to page 1Electrical Data Nominal resistance Resistance tolerance Independent linearity Electrical travel Repeatability Temperature coefficient of the voltage divider Recommended wiper current Max. wiper current in case of malfunction Power rating P Min. life (electrical) Mechanical Data Mechanical travel Adjusting force of the push rod Adjusting force of the push rod with return spring Min. life (mechanical) Operating temperature Storage temperature Protection class Standards Insulating resistance (500 VDC, 1bar, 2s) Dielectric strength (VAC, 50Hz, 1min, 1bar) Vibration (Amax = 0.75mm, f = 30 ......
Open the catalog to page 2Electrical Data Nominal resistance Resistance tolerance Independent linearity Electrical travel Repeatability Temperature coefficient of the voltage divider Recommended wiper current Max. wiper current in case of malfunction Power rating P Min. life (electrical) Mechanical Data Mechanical travel Adjusting force of the push rod Adjusting force of the push rod with return spring Min. life (mechanical) Operating temperature Storage temperature Protection class Standards Insulating resistance (500 VDC, 1bar, 2s) Dielectric strenght (VAC, 50Hz, 1min, 1bar) Vibration (Amax = 0.75mm, f = 30 ......
Open the catalog to page 3Electrical Data Nominal resistance Resistance tolerance Independent linearity Electrical travel Repeatability Temperature coefficient of the voltage divider Recommended wiper current Max. wiper current in case of malfunction Power rating P Min. life (electrical) Mechanical Data Mechanical travel Adjusting force of the push rod Adjusting force of the push rod with return spring Min. life (mechanical) Operating temperature Storage temperature Protection class Standards Insulating resistance (500 VDC, 1bar, 2s) Dielectric strength (VAC, 50Hz, 1min, 1bar) Vibration (Amax = 0.75mm, f = 30 ......
Open the catalog to page 4Electrical Data Nominal resistance Resistance tolerance Independent linearity Electrical travel Repeatability Temperature coefficient of the voltage divider Recommended wiper current Max. wiper current in case of malfunction Power rating P Min. life (electrical) Mechanical Data Mechancial Weg Adjusting force of the push rod Min. life (mechanical) Operating temperature Storage temperature Protection class Standards Insulating resistance (500 VDC, 1bar, 2s) Dielectric strength (VAC, 50Hz, 1min, 1bar) Vibration (Amax = 0.75mm, f = 30 ... 2000 Hz) Shock (half sine pulse, 7 ms) KL1000 (KL100)...
Open the catalog to page 5