general catalog
72Pages

{{requestButtons}}

Catalog excerpts

general catalog - 2

Electrochemistry ORDER NUMBERS LOGIC Order numbers have maximum 6 characters and follow mainly = the following rules: pH/mV/Ion/rH > 2 = conductivity A accessories TDS B buffers, calibration solutions resistivity C multi-parameter instruments D data-loggers = E electrophoresis equipment dissolved oxygen K conductometers = P pH meters R controllers temperature S electrodes, accessories = T thermometers electrodes # type number calibration solutions electrode holder meters: flow through cell - meter only without accessories K meter kit with conductivity/ATC electrode = P meter kit with pH/ATC...

Open the catalog to page 2
general catalog - 4

PRICES We certify that the goods are thoroughly Our shipping instructions should be followed Prices are subject to change without notice. inspected and tested at the factory prior by the sender. Ask for written quotations or an updated to shipment and found to meet all require - We reserve the right to refuse any unauthor - price-list if any doubt about availability and ments defined by contract under which it is ised return. price of a product. For orders less than 250 furnished. EUR we reserve the right to add a handling However, should damage have occurred, RESTOCKING fee and banking...

Open the catalog to page 4
general catalog - 5

Model C830 C861 C862 C863 C864 C868 C931 C932 C933 Benchtop 켼 켼 켼 Portable 켼 Multi-channel 3 4 4 4 8 4 pH 0...14 -2...16 -2...16 -2...16 -2...16 -2...16 -2...16 -2...16 -2...16 pH resolution (pH) 0.01 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 pH calibration points 2 5 5 5 5 5 5 5 5 mV 1000 ѱ2000 2000 ѱ2000 2000 ѱ2000 2000 ѱ2000 2000 mV resolution (mV) 1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 mV calibration points 1 1 1 1 1 1 1 1 1 rH > 2 0...42 rH > 2 resolution (rH > 2 ) 0.01 Ion concentration Ѽ Ion calibration points 2 2 2 Conductivity (mS/cm) 0...100 0...2000 0...2000 0...2000 0...2000...

Open the catalog to page 5
general catalog - 6

Temp. Compensation 0...100C ISO-pH 6...8 pH > CONDUCTIVITY Range 0...100 mS/cm > Resolution 0.1 S/cm Accuracy 1% f.s. of range > Temp. Coefficient natural waters (EN27888) > INPUTS pH/mV BNC, 10 > 12 Ω Conductivity BNC > POWER SUPPLY Mains 210...250 VAC, 50/60 Hz > DIMENSIONS WxDxH 13x18x10 cm WEIGHT Meter 600 g > CODE DESCRIPTION C830 meter only option comprises meter + manual + mains adaptor C830X meter kit without electrodes: C830 + 2x50 ml buffers (pH 4 and 7) + 50 ml electrolyte (3M KCl) + 50 ml conductivity standard (0.01M KCl) C830P pH/C meter kit: C830 + pH/ATC electrode SP10T +...

Open the catalog to page 6
general catalog - 7

= Display = Inputs Bright LCD screen with white backlight for better readability. C861: two inputs for pH or mV + corresponding reference inputs. Stability indicator prompts the user when readings should be tak - C862, C863: two inputs for pH, mV and/or Ion + corresponding en. reference inputs. Channel-2 can also be used for dissolved oxygen Hold function allows to freeze the display for convenient reading or measurements. recording. C864: six inputs for pH, mV and/or Ion + corresponding reference The interactive LCD screen provides step by step instructions in the inputs. language of your...

Open the catalog to page 7
general catalog - 8

CODE DESCRIPTION C861 meter only option comprises meter + manual + mains adaptor C861X meter kit without electrodes: C861 + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) + 3x50 ml conductivity standards (0.01, 0.1 and 1M KCl) C861P pH/C meter kit: C861 + pH/ATC electrode SP10T + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) C861K еS/mS/C meter kit: C861 + conductivity/ATC electrode SK10T + 3x50 ml conductivity standards (0.01, 0.1 and 1M KCl) C861T pH/еS/mS/C meter kit: C861 + pH electrode SP10B + conductivity electrode SK10B + ATC probe ST10N + 3x50 ml...

Open the catalog to page 8
general catalog - 9

CODE DESCRIPTION C862 meter only option comprises meter + manual + mains adaptor C862X meter kit without electrodes: C862 + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) + 3x50 ml conductivity standards (0.01, 0.1 and 1M KCl) C862P pH/аC meter kit: C862 + pH/ATC electrode SP10T + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) C862K S/mS/հC meter kit: C862 + conductivity/ATC electrode SK10T + 3x50 ml conductivity standards (0.01, 0.1 and 1M KCl) C862Z O > 2 /C meter kit: C862 + dissolved oxygen electrode SZ10T C862T pH/еS/mS/O > 2 /C meter kit: C862 + pH...

Open the catalog to page 9
general catalog - 10

CODE DESCRIPTION C863 meter only option comprises meter + manual + mains adaptor C863X meter kit without electrodes: C863 + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) + 3x50 ml conductivity standards (0.01, 0.1 and 1M KCl) C863P pH/аC meter kit: C863 + pH/ATC electrode SP10T + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) C863K S/mS/հC meter kit: C863 + conductivity/ATC electrode SK10T + 3x50 ml conductivity standards (0.01, 0.1 and 1M KCl) C863Z O > 2 /C meter kit: C863 + dissolved oxygen electrode SZ10T C863T pH/еS/mS/O > 2 /C meter kit: C863 + pH...

Open the catalog to page 10
general catalog - 11

CODE DESCRIPTION C864 meter only option comprises meter + manual + mains adaptor C864X meter kit without electrodes: C864 + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) + 3x50 ml conductivity standards (0.01, 0.1 and 1M KCl) C864P pH/аC meter kit: C864 + pH/ATC electrode SP10T + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) C864K S/mS/հC meter kit: C864 + conductivity/ATC electrode SK10T + 3x50 ml conductivity standards (0.01, 0.1 and 1M KCl) C864T pH/S/mS/հC meter kit: C864 + pH electrode SP10B + conductivity electrode SK10B + ATC probe ST10N + 3x50 ml...

Open the catalog to page 11
general catalog - 12

Specifications C861 C862 C863 C864 pH Range -2...+16 pH -2...+16 pH -2...+16 pH -2...+16 pH Resolution 0.001 pH 0.001 pH 0.001 pH 0.001 pH Accuracy 0.1% 1 digit 0.1% ѱ 1 digit 0.1% 1 digit 0.1% ѱ 1 digit Calibration 1...5 points 1...5 points 1...5 points 1...5 points Buffers 9 pre-programmed 9 pre-programmed 9 pre-programmed 9 pre-programmed 5 user specified 5 user specified 5 user specified 5 user specified Temperature Compensation -30...+130C -30...+130аC -30...+130C -30...+130аC ISO-pH 6...8 pH 6...8 pH 6...8 pH 6...8 pH Slope 80...120% 80...120% 80...120% 80...120% Zero Point (Eo) 999...

Open the catalog to page 12

All CONSORT catalogs and technical brochures