200250 ProTIM-C
17Pages

{{requestButtons}}

Catalog excerpts

200250 ProTIM-C - 1

Bently Nevada Machinery Condition Monitoring Description The 200250 dual-input ProTIM-C (conduit mount) provides 2 channels of measurement. All acceleration-to-velocity (A-V) channels condition the signal from an accelerometer and integrate it to velocity units. The low frequency A-V channels are better suited for slower speed applications. A-V with Acceleration Enveloping (AE) channels provide both integrated velocity units and advanced AE signal conditioning. Temperature channel types include K-type thermocouples and 100Ω Platinum (Pt) RTDs with electrical isolation. Each channel is independent and specified when the ProTIM is ordered. Table 1: ProTIM Measurement Types and Transducers Measurement Type Interfaced Transducer Acceleration-to-Velocity (General Purpose) K-type Thermocouple Industry standard Rack Buffered Output (RBO)

Open the catalog to page 1
200250 ProTIM-C - 2

Specifications All specifications are at +25 ± 5°C (+77 ± 9°F) unless otherwise specified. Operation outside the specified limits will result in false or inaccurate readings. Table 1: ProTIM and Transducers Frequency Responses Device This Frequency response represents the System ProTIM & Transducer. For details on individual device frequency response refer to ProTIM and Transducers Frequency Responses Open transducer signal, power, or common is “Not OK”. Shorted leads are “Not OK” except for SIG+ shorted to SIGor common shorted to shield. Upper Freq Low Frequency A–V Channels (with 200155)...

Open the catalog to page 2
200250 ProTIM-C - 3

Temperature Channels Measurement Range Resolution 10 Hz to 1 kHz (600 cpm to 60,000 cpm) ± 20% (± 2.0 dB) 2. ProTIM and Transducers Frequency Responses Open transducer signal, power, or common is “Not OK”. Not OK Range: Shorted leads are “Not OK” except for SIG+ shorted to SIGor common shorted to shield. Maximum temperature ramp rate: ±0.5°C/min. RTD OK Range This Frequency response represents the System ProTIM & Transducer. For details on individual device frequency response, ProTIM and Transducers Frequency Responses ±4.45°C (±8°F), RTD lead wire error not included -31°C to +213°C (-25°F...

Open the catalog to page 3
200250 ProTIM-C - 4

Rack Buffered Output Channels OK Range Frequency Response AC: 1 Vpp to 8 Vpp full scale Measurement DC: 0 to –20 Vdc Range (See Table 2) Full Scale Resolution Frequency Response Not OK Range Measurement Current: +4 mA to +20 mA Range Voltage: +1 Vdc to 5 Vdc Over Range ±1% of full-scale value Typical Current: Over +3.2 mA Voltage: Over 0.8 Vdc Frequency Response Pressure Channels Measurement 0 to 50 mV Range Resolution ±8.5% of the transducer fullscale rating (transducer accuracy not included) Minimum Target size Process Variable Channels +/-1.2 mils @ mid-scale range. Frequency Response...

Open the catalog to page 4
200250 ProTIM-C - 5

Shaft Diameter: Minimum: 50.8 mm (2 in) Recommended minimum: 76.2 mm (3 in) Measurements on shaft diameters smaller than 50 mm (2 in) usually require close spacing of radial vibration or axial position transducers with the potential for their electromagnetic emitted fields to interact with one another (cross-talk), resulting in erroneous readings. Care should be taken to maintain minimum separation of transducer tips, generally at least 40 mm (1.6 in) for axial position measurements or 74 mm (2.9 in) for radial vibration measurements. Radial vibration or position measurements on shaft...

Open the catalog to page 5
200250 ProTIM-C - 6

Voltage rating 300 Vrms Screw-on, 5-pin, keyed connector on the ProTIM-C end and a PT06F8-4S (or equivalent) on the transducer end. Connector coupling nuts consist of 1/220 UNF-threaded 2011 T3 aluminum or UV-stabilized black nylon. Contact material is gold-plated nickel-coated brass. Capacitance Between Conductors Between Conductor and Drain Wire Cable assembly meets UL 2238. Cable meets IP67 ingress protection. 85033 Trendmaster SPA/TIM line cable Use to connect a SPA to the ProTIM-C. For substitutions, reference guide 101206. Operating Temperature 4x 18 AWG stranded tinned copper 1x 18...

Open the catalog to page 6
200250 ProTIM-C - 7

Compliance and Certifications FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: l This device may not cause harmful interference. l This device must accept any interference received, including interference that may cause undesired operation. RoHS RoHS Directive 2011/65/EU ATEX EN 60079-0: 2012/A11:2013 EN 60079-11:2012 EN 60079-15:2010 EN 60079-28:2015 (DSM 149744 only) EN 60079-31:2014 (TMGI 162459-01 only) ATEX Directive 2014/34/EU Maritime ABS 2009 Steel Vessels Rules 1-1-4/7.7,4-8-3/1.11.1,4-9-7/13

Open the catalog to page 7
200250 ProTIM-C - 8

Hazardous Area Approvals TMGI (162459-01) For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from Bently.com. CSA/NRTL/C (Approval Options 05) Ex ia IIC T4 Ga Installed with intrinsically safe zener barriers per drawing 112M7732 Installed without barriers per drawing 112M7732 Class I Zone 0: AEx ia IIC T4 Ga Class I, Div 1 Groups A, B, C & D Class II, Groups E, F & G Class III T4 @ -40° C[ Ta [+ 100° C (-40° F [ Ta [+212° F) Ex nA IIC T4 Gc Class I Zone 2: AEx nA IIC T4 GcClass I, Div 2 Groups A, B, C &D T4 @...

Open the catalog to page 8
200250 ProTIM-C - 9

For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from Bently.com. Ordering Information Process Variable BB option availability is dependent on AA option chosen. Not all BB options are available with each AA option. A: Channel A Input Option Multiple Approvals D: Conduit Body Style Appleton Style C body, malleable iron Appleton Style E body, malleable iron Appleton Style C body, aluminum Appleton Style E body, aluminum Weatherproof housing mount Rack buffered Output Process Variable The 200125 is the...

Open the catalog to page 9
200250 ProTIM-C - 10

Transducer Cable (for use with 200150, 200150, and 200157 accelerometers) Use the 200151 with the 200250 ProTIM only with applications using either a 142485 Housing Cable Adapter or a 141887 Conduit Cable Adapter 4.0 metre (13.1 feet) cable 6.0 metre (19.7 feet) cable Extra Terminal Plugs. For SPA line connection. 3 terminal plugs provided with each ProTIM-C module The 200151 Accel Cable Environmental Boot Field Installation Kit. Contains everything needed to install the boot in the field. It includes 10 sets of boots and clamps, silicone lubricant, easy-to-use installation tool, and an...

Open the catalog to page 10

All Condition Monitoring and Protection catalogs and technical brochures

  1. Orbit DCM

    15 Pages