The Condair ME evaporative cooler is designed for indirect exhaust air cooling, offering a simple structure, economical operation, and durable components. It features a patented humidifier box for optimal vaporizing efficiency.
Key Features
  • Freely Selectable Media: Various media options for evaporation bodies based on system requirements.
  • Water Distribution: Ensures constant and homogeneous water distribution.
  • Removable Evaporation Bodies: Allows removal during non-use periods to eliminate air resistance.
  • Modular Hydraulics Unit: Features a flexible pumping concept with multiple smaller pumps for energy-efficient operation.
  • Integration and Control: Compatible with building management systems like Modbus and BACnet, featuring intuitive touch controller operation.
Materials and Construction
  • Glass Fiber Medium: Suitable for systems with available drinking or soft water.
  • DI Water-Resistant Medium: Ideal for low-maintenance and efficient operation, free from glass fibers.
Energy Efficiency
Indirect evaporative cooling reduces the capacity and power requirements of mechanical cooling systems by utilizing the thermodynamic principle of air cooling through water evaporation. Energy savings can be calculated using Condair Coolblue® software, which simulates energy contributions and potential savings.
Technical Specifications
  • Installation Length: 695 to 795 mm depending on output.
  • Air Speed: Max 3.5 m/s without droplet separator, 4.5 m/s with separator.
  • Water Connection Pressure: 2–10 bar(g).
  • Water Temperature: 5–45°C.
  • Voltage Supply: 230 V / 1 Ph / 50–60 Hz.
  • Protection Ratings: Controller and circulation pump IP 54, valves IP 65.
  • Fire Safety: Humidifier box meets DIN EN 53438 class F1.
  • Certification: CE marked.
Contact Information
Condair GmbH and regional centers across Germany and Austria provide support and services.
See more

Catalog excerpts

Condair ME-1

EFFICIENT COOLING Evaporative Cooler Condair ME Humidification and Evaporative Cooling

 Open the catalog to page 1
Condair ME-2

Efficient Evaporative Cooling Touch Controller The innovative control allows intuitive operation of the device, excellent transparency of function, and resource-friendly operation. Equal Distribution of Water The distribution panels above the evaporation bodies ensure constant, homogeneous distribution of the humidifying water. Perfect Integration into Building Management Systems May be connected to any current BMS system (e.g. Modbus and BACnet). Freely Selectable Media With evaporation bodies, you can choose between various different media which can be selected based on the system situation....

 Open the catalog to page 2
Condair ME-3

Water level sensor Conductivity sensor Inspection cover Water inlet Modular Hydraulics Unit Unlike conventional evaporative coolers, the Condair ME is not based on a highperformance central pump but instead uses several smaller pumps which can be activated or deactivated as needed. This modular structure enables highly energy saving operation and makes the energy-intensive partial load operation of a central pump, which has to cover the entire output spectrum, superfluous. The hydraulics unit can either be attached inside the air conditioning device or outside on the wall of the device. Water...

 Open the catalog to page 3
Condair ME-4

Energy Detection with Building Simulation Using Condair Coolblue® Representation of indirect evaporative cooling in h,x diagram. OUTA downstream from rotor downstream from the cooler 50,000 kWh Heat recovery share Indirect evaporative cooling Graphical representation of energy contributions produced for the cooling of buildings in the sample air conditioning system. Calculated using the Coolblue 2.0 software tool from Condair. Indirect evaporative cooling in air conditioning systems is one way of generating regenerative cooling capacity. The reduction of the capacity and power requirement of...

 Open the catalog to page 4
Condair ME-5

© 02/2015 Technical modifications and errors excepted Standard model DI Water-Resistant Low-energy pumps Shortest construction length Remote signaling of operational readiness / operating mode / maintenance / faults Touch screen operation Self-diagnostic system Real-time clock Modbus and BACnet connection Options Conductivity monitoring for conduction-guided water blowdown Supply water connection set Channel sealing sheet made of stainless steel UV lamp for the water basin Disinfection unit for dosing from Condair DES Start accelerator Condair WET including dosing pump Supply water connection...