con50

con50

con50

Product catalog summary
Specifications:
The Con50 Linear In-line Actuator is designed with a maximum static load capacity of 4700 N for PA brackets and 16800 N for aluminum or stainless steel brackets. It operates within a temperature range of -20°C to +70°C and can be stored between -40°C to +70°C. The actuator has an IP66 protection class, ensuring resistance to dust and water.
Materials and Construction:
The motor and actuator tube are made of powder-coated steel, while the piston rod is stainless steel. The front and rear brackets are constructed from Polyamide (PA).
Electrical Specifications:
The actuator is powered by a 24 VDC permanent magnet motor with various gear ratios, allowing for different maximum loads and speeds. The maximum current varies depending on the gear ratio, with an absolute maximum voltage of 28 VDC. A 12 VDC motor option is also available.
Performance and Limitations:
The actuator has a duty cycle of 10%, meaning it can operate for 2 minutes followed by an 18-minute rest. For stroke lengths greater than 400 mm, the maximum load is limited to 2000 N.
Options and Customizations:
Various options are available, including stainless steel versions, brackets with clevis or spherical bearings, Hall sensors for positioning, and a low noise version. Custom cable lengths and stroke lengths can be requested, and the actuator can be customized in any RAL color.
Mounting and Installation:
Proper mounting methods are crucial, with recommendations to avoid clamping actuators on tubing and ensuring brackets can rotate on axles. Radial forces should be avoided to maintain performance.
Additional Features:
The actuator is available in a Harsh Environment (HE) version, tested to IP68 and IP69 standards, and can be certified according to IEC60601-1 standards for medical applications.
Procedures and Recommendations:
Do not expose actuators to hammer strikes during installation. Ensure power supply has over-current protection to prevent damage. Maintain cleanliness of the piston tube and be cautious of voltage drops with longer cable lengths. For medical applications, adhere to specific environmental conditions and use medically approved power sources. Performance may be affected by dust, water sealing, and ambient temperature variations.
Warnings:
Actuators should not be used in safety-critical applications. Customers are responsible for validating product suitability for specific applications.
Disclaimer:
Concens products are subject to continuous development and specifications may change without notice. The company is not liable for documentation errors.
See more

Catalog excerpts

con50-1

con50 Linear In-line Actuator Standard Specifications (Specifications for non-standard actuators, eg. HE-version, may vary) Motor/Gear 24 VDC permanent magnet motor (max. current for ratio 4-14-17-24 is 8 A, ratio 49 is 7 A, ratio 84 is 4,5 A, absolute max. voltage is 28 VDC) Gear ratio 4 14 17 24 49 84 Maximum load Speed at maximum load 12 VDC permanent magnet motor (max. current for ratio 4-14-17-24 is 16 A, ratio 49 is 14 A, ratio 84 is 9 A, absolute max. voltage is 14 VDC) Gear ratio 14 17 24 49 84 Maximum load Speed at maximum load Max. static load/ PA brackets: 4700 N Alu/Stainless steel: 16800 N Self locking force Depending on stroke length for push-applications Max. Load limited to 2000 N for stroke lengths > 400 mm Temperature Operation: - 20 ˚C to + 70 ˚C Storage: - 40 ºC to + 70 ºC Protection class IP66 Cable specification 1 m, 2 x 1.3 mm² (AWG16), Ø = 6.4 mm, black, Molex Mini-Fit Jr. 6 pin Bending Radius 6 x cable diameter Materials Motor and actuator tube are powder coated steel Piston rod is stainless steel Front and rear brackets are PA Duty cycle Max. 10 % or 2 minutes in use followed by 18 minutes rest Color Black (RAL 9005) Stroke length/weight Stainless steel versions (AISI 316) Brackets in aluminum or stainless steel Brackets with clevis Brackets with spherical bearings Hall sensors for positioning and/or synchronization HE (Harsh Environment) version (gear ratio 1:4 not available) Tested according to IP68 and IP69 and passed the criteria for a depth of one meter for one hour. Test reports are available on request. Low noise version Spline and emergency lowering Other cable lengths (1 - 9 m) Check for updates at www.concens.com Version certified according to IEC60601-1, ANSI/ AAMI/ES60601-1, CAN/CSA-22.2 No60601-1 available (24 VDC only) Available in all RAL colors Other stroke lengths available Customised front and rear brackets Customised build-in-dimensions Contact Concens for any special requirements D ATA S H E E T

 Open the catalog to page 1
con50-2

Ratio 1:4 Load 500 N, speed 70 mm/s Graphs are indicative only Use in the dashed area is not recommended. Please contact Concens for further information. Graphs are indicative only push / pull General dimensional variation: +/- 1 mm push / pull Gear Ratio Build-in Dimension BID Standard Clevis Rear + 15 mm + 15 mm Build-in Dimension BID+ 14 mm + 15 mm Stroke lengths > 750 mm + 100 mm (On request) Harsh Enviroment

 Open the catalog to page 2
con50-3

Max. Max. static steel Max. static steel static load Stainless steel load Stainless load Stainless 16800N clevis 16800N 16800N with with clevis with clevis Stainless steelsteel Stainless load Stainless Stainless Max. Max. static load Max. static steel steel static load with 16800N clevis with with with clevis 16800N clevis 16800N clevis Max. static steelsteel Max. static steel steel Max. load Max. static Stainless static load Stainless load load Stainless Stainless 16800N clevis brackets 16800N with 16800N clevis with with clevis Con50 standard brackets Con50with clevis brackets Con5016800N standard...

 Open the catalog to page 3
con50-4

Con50 con50Item number combination Item Number Combination 5 0 0 0 Type ID Piston ring color Tube color Brackets Steel & IP Class Hall sensors (- without hall /+ with hall) Cable & Connector Cable Length Pitch (- without low noise /+ with low noise) Stroke length Product series Recommendations and warnings Never expose the actuator to hammer strike during installation or in other situations. Retrofitted bushings should be pressed into the bracket-borings. No hammering. Power supply without over-current protection can cause serious damage to the actuator at mechanical end-stop or when actuator...

 Open the catalog to page 4

All Concens A/S catalogs and technical brochures

  1. con25

    4  Pages

  2. icon35/50/60

    2  Pages

  3. con35

    4  Pages

  4. con60

    4  Pages

  5. C2-10

    4  Pages

  6. C2-20

    4  Pages

  7. C2-30

    4  Pages

  8. C4-Controller

    4  Pages

  9. Hall Option

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.