video corpo

con25
4Pages

{{requestButtons}}

Catalog excerpts

con25 - 1

con25 Linear In-line Actuator Standard Specifications Gear ratio Maximum load Speed at maximum load Motor/Gear 24 VDC permanent magnet motor (max. current 0,4 A, absolute max. voltage is 28 VDC) 12 VDC permanent magnet motor (max. current 0,7 A, absolute max. voltage is 14 VDC) Max. static load/ Self locking force Temperature PA brackets: 1000 N Depending on stroke length for push-applications Operation: - 20 ºC to + 70 ºC Protection class Cable specification 1 m, 2 x 0,50 mm² (AWG20), Ø = 4.8 mm, black, Molex Mini-Fit Jr. 6 pin Bending Radius Motor and actuator tube are powder coated aluminum and piston rod is aluminum. Front and rear brackets are PA Duty cycle Max. 10 % or 2 minutes in use followed by 18 minutes rest Stroke length/weight Stroke Actual weight may vary depending on model and options selected Options Brackets with clevis on request Other cable lengths (1 - 9 m) Hall sensors for positioning and/or synchronization Black cable shielded or without shield and with or without Molex Minifit connector Check for updates at www.concens.com On Request Available in all RAL colors Customised stroke lengths available Customised front and rear brackets Customised build-in-dimensions Contact Concens for any special requirements

Open the catalog to page 1
con25 - 2

Use in the dashed area is not recommended. Please contact Concens for further information. General dimensional variation: +/- 1 mm Gear Ratio

Open the catalog to page 2
con25 - 3

Standard Brackets Recommended Mounting Methods Do not clamp actuators on tubing. Always keep both brackets mounted in the same orientation and ensure to flush mount actuator. Brackets must always be able to rotate on axels in mountings. concens Concens A/S Øresundsvej 7 DK6715 Esbjerg N. Denmark www.concens.com Customer: Avoid radial forces at all times.

Open the catalog to page 3
con25 - 4

con25 Item Itemnumber Number Combination combination 2 5 0 0 Type ID Piston ring color Tube color Brackets Steel & IP Class Hall sensors (- without hall /+ with hall) Cable & Connector Cable Length Pitch Voltage Gearing Low noise (- without low noise /+ with low noise) Stroke length Product series Recommendations and warnings Never expose the actuator to hammer strike during installation or in other situations. Power supply without over-current protection can cause serious damage to the actuator at mechanical end-stop or when actuator is overloaded in another way. Keep piston tube clean....

Open the catalog to page 4

All Concens A/S catalogs and technical brochures

  1. icon35/50/60

    2 Pages

  2. con35

    4 Pages

  3. con50

    4 Pages

  4. con60

    4 Pages

  5. C2-10

    4 Pages

  6. C2-20

    4 Pages

  7. C2-30

    4 Pages

  8. Hall Option

    4 Pages