C2-10 Control and protection of electric actuators The C2-10 is developed for controlled ON-OFF Operating and direction change of Concens actuators. The C2-10 has advanced current limit features. It limits the actuator current in start-up, braking and jam-situations and in that way protects the motor and the application. The C2-10 also has a fault in- and output which indicates error/overcurrent status and can be used to stop the actuator (for example if an emergency-stop switch is used). The C2-10 is only suitable for use with actuators without hall sensors. Features Adjustable start ramp Adjustable stop ramp Adjustable current limit Continuous-mode, impulse-mode High momentary load capacity Easy interfacing to PLC etc. Connectors and terminals The start and stop ramp times are individually adjustable to DIN-rail fittable suit each application. In other words the motor voltage can Status LED be controlled to give a preferred smooth start and stop. When the C2-10 controller is without power, the motor is dynamically braked with so called short-circuit braking, i.e. Technical Data the motor poles are connected together. The reverse and Supply 12/24 VDC (filtered max forward inputs can be set to work with negative or positive ripple < 30 % @ full load) voltage by moving a jumper (See Fig. 3). Over voltage protection 40 V This datasheet is related to C2-10 firmware version 1.7 (v1.7) only. Check for updates at www.concens.com Idle current Approx. 15 mA Driving current 10 A continuous, 16 A with duty cycle 50 % Max 16 A on duty 2 min Current limit 0,5 ... 16 A Current trip delay 20 ms Start delay 5 ms Voltage loss 0,5 V ( I motor = 4 A) PWM frequency 2 kHz Ramps 0,1 ... 2,5 s Digital inputs ‘High’ @ Uin 4 V → supply voltage, ‘Low’ @ Uin 0 V → 1 V Operating temp. (Ta) - 20 °C to + 60 °C Weight 36 g Dimensions 73 x 42 x 26 mm (L x W x H)
Open the catalog to page 1 Note: If the power consumption is higher than 8 A continuously, screw terminals must be used due to the size of leads in layout. Pin 1 is Supply GND, Pin 2 is Supply + (12 VDC/24 VDC). Note: If actuators with hall...
Open the catalog to page 2 Refer to datasheet for actual actuator for maximum current recommended when adjusting current limit Control mode When jumper is put in mode ‘neg’ (left hand side) a negative (GND) signal is put on terminal 7 and 8 to run motor. NOTE: When using the connectors for remote control, the jumper MUST be in ‘neg’ mode (left side). When using ‘neg’ mode, terminal 9 can be used as the negative supply. Parameter #1 is as default set to ‘0’ which enables ‘continous mode’. If #1 is changed to ‘1’ ‘impulse mode’ is enabled. Use...
Open the catalog to page 3C2-10-PCB-00-0000-00 board alone, weight 36 g 73 x 42 x 26 mm (L x W x H) C2-10-DIN-00-0000-00 DIN rail version, weight 66 g 90 x 46 x 56 mm (L x W x H) BOX-version is not for use with Molex Minifit, only open ends. C2-‐10 Part number combina3on C2-10 Part number 00 = All s= All standard 00 tandard XX = Special XX = Special 0000 0000 = nconfigured = Std. U Std. Unconfigured 0001 0001s= 2 A sealed 24 V) = 2 A ealed (Con35 (Con35, 24 V) 0002 0002s= 4 A sealed 12 V) = 4 A ealed (Con35 (Con35, 12 V) 0003 0003s= 8 A sealed 24 V) = 8 A ealed (Con50 (Con50, 24 V) 0004 0004 = ealed (Con50 12 V) = 16...
Open the catalog to page 4All Concens A/S catalogs and technical brochures
-
con25
4 Pages
-
icon35/50/60
2 Pages
-
con35
4 Pages
-
con50
4 Pages
-
con60
4 Pages
-
C2-20
4 Pages
-
C2-30
4 Pages
-
C3 concens control concept
2 Pages
-
C4-Controller
4 Pages
-
Hall Option
4 Pages