C2-10

C2-10

C2-10

Product catalog summary
Features
  • Adjustable start and stop ramps
  • Adjustable current limit
  • Continuous and impulse modes
  • High momentary load capacity
  • Easy interfacing with PLCs
  • DIN-rail mountable with status LED
Technical Data
  • Supply: 12/24 VDC with overvoltage protection up to 40 V
  • Idle current: Approx. 15 mA
  • Driving current: 10 A continuous, 16 A with 50% duty cycle
  • Current limit: 0.5 to 16 A
  • Operating temperature: -20°C to +60°C
  • Dimensions: 73 x 42 x 26 mm
General Description

The C2-10 is designed for controlled ON-OFF operation and direction change of Concens actuators, featuring advanced current limit protection. It is suitable for actuators without hall sensors and includes a fault input/output for error indication.

Wiring and Connectors
  • Screw terminals for power and actuator connections
  • Molex 2-pin connector for power supply
  • Fault terminal serves as both input and output
Operational Features
  • Trip feature cuts motor voltage if current limit is exceeded
  • Kick-start feature provides 100 ms at full speed
  • Control mode can be set to continuous or impulse
Recommendations and Warnings
  • Ensure power supply can provide sufficient current
  • Use external fuse as the controller has no internal fuse
  • Adjust max current to be 10% higher than the actuator's running current
Product Variants
  • PCB, DIN rail, and BOX versions available
  • Various configurations for different current ratings
Disclaimer

Concens products are continuously developed and tested, but customers must validate their suitability for specific applications. Specifications may change without notice.

See more

Catalog excerpts

C2-10-1

C2-10 Control and protection of electric actuators The C2-10 is developed for controlled ON-OFF Operating and direction change of Concens actuators. The C2-10 has advanced current limit features. It limits the actuator current in start-up, braking and jam-situations and in that way protects the motor and the application. The C2-10 also has a fault in- and output which indicates error/overcurrent status and can be used to stop the actuator (for example if an emergency-stop switch is used). The C2-10 is only suitable for use with actuators without hall sensors. Features Adjustable start ramp Adjustable stop ramp Adjustable current limit Continuous-mode, impulse-mode High momentary load capacity Easy interfacing to PLC etc. Connectors and terminals The start and stop ramp times are individually adjustable to DIN-rail fittable suit each application. In other words the motor voltage can Status LED be controlled to give a preferred smooth start and stop. When the C2-10 controller is without power, the motor is dynamically braked with so called short-circuit braking, i.e. Technical Data the motor poles are connected together. The reverse and Supply 12/24 VDC (filtered max forward inputs can be set to work with negative or positive ripple < 30 % @ full load) voltage by moving a jumper (See Fig. 3). Over voltage protection 40 V This datasheet is related to C2-10 firmware version 1.7 (v1.7) only. Check for updates at www.concens.com Idle current Approx. 15 mA Driving current 10 A continuous, 16 A with duty cycle 50 % Max 16 A on duty 2 min Current limit 0,5 ... 16 A Current trip delay 20 ms Start delay 5 ms Voltage loss 0,5 V ( I motor = 4 A) PWM frequency 2 kHz Ramps 0,1 ... 2,5 s Digital inputs ‘High’ @ Uin 4 V → supply voltage, ‘Low’ @ Uin 0 V → 1 V Operating temp. (Ta) - 20 °C to + 60 °C Weight 36 g Dimensions 73 x 42 x 26 mm (L x W x H)

 Open the catalog to page 1
C2-10-2

          Note: If the power  consumption is higher than 8 A continuously, screw  terminals must be used due  to the size of leads in layout. Pin 1 is Supply GND, Pin 2  is Supply +   (12 VDC/24 VDC). Note: If actuators with hall ...

 Open the catalog to page 2
C2-10-3

           Refer to datasheet for actual actuator for maximum current recommended when adjusting current limit Control mode When jumper is put in mode ‘neg’ (left hand side) a negative (GND) signal is put on terminal 7 and 8 to run motor. NOTE: When using the connectors for remote control, the jumper MUST be in ‘neg’ mode (left side). When using ‘neg’ mode, terminal 9 can be used as the negative supply. Parameter #1 is as default set to ‘0’ which enables ‘continous mode’. If #1 is changed to ‘1’ ‘impulse mode’ is enabled. Use C2-USB/C2...

 Open the catalog to page 3
C2-10-4

C2-10-PCB-00-0000-00 board alone, weight 36 g 73 x 42 x 26 mm (L x W x H) C2-10-DIN-00-0000-00 DIN rail version, weight 66 g 90 x 46 x 56 mm (L x W x H) BOX-version is not for use with Molex Minifit, only open ends. C2-‐10 Part number combina3on C2-10 Part number 00 = All s= All standard 00 tandard XX = Special XX = Special 0000 0000 = nconfigured = Std. U Std. Unconfigured 0001 0001s= 2 A sealed 24 V) = 2 A ealed (Con35 (Con35, 24 V) 0002 0002s= 4 A sealed 12 V) = 4 A ealed (Con35 (Con35, 12 V) 0003 0003s= 8 A sealed 24 V) = 8 A ealed (Con50 (Con50, 24 V) 0004 0004 = ealed (Con50 12 V) = 16 A...

 Open the catalog to page 4

All Concens A/S catalogs and technical brochures

  1. con25

    4  Pages

  2. icon35/50/60

    2  Pages

  3. con35

    4  Pages

  4. con50

    4  Pages

  5. con60

    4  Pages

  6. C2-20

    4  Pages

  7. C2-30

    4  Pages

  8. C4-Controller

    4  Pages

  9. Hall Option

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.