Now in its ninth decade, Conbraco Industries, Inc. is a leading manufacturer of flow control products for U.S. and international markets. The company’s headquarters is based in Matthews, North Carolina with manufacturing plants and foundries located in Pageland and Conway, South Carolina. Conbraco has a history of new product development and innovation that dates back to the company’s inception in 1928. Today, the Conbraco line of products is marketed under the “Apollo Valves” brand and includes: ball valves, butterfly valves, backflow prevention devices, water pressure reducing valves, mixing...
Open the catalog to page 2FLANGED SERIES Y-STRAINERS DESCRIPTION The Apollo InternationalTM YCF Strainers are designed to protect piping systems and process equipment from unwanted foreign particles with minimum pressure loss. PERFORMANCE RATING Working pressure (non-shock): STEAM 150 PSIG @ 353°F CWP 200 PSIG @ 150°F HOLE PRESENT ON 4" THRU 12" ONLY Iron strainer with flat face flanges conforms to ASME/ANSI 16.1 Class 125 One piece cast body meets ASME standard Lead free (NSF-372 ANSI) All models epoxy coating (FDA CFR21, Section 175.300) Equipped with bolted cover employing flat gasket seal Upper and lower machined...
Open the catalog to page 3FLANGED SERIES Y-STRAINERS engineering data - screen openings FACTORS TO CONSIDER PURPOSE If the basket strainer is being used for protection rather than direct filtration, Apollo’s standard screens will suffice in most applications. SERVICE With services that require extremely sturdy screens, such as high pressure/ temperature applications or services with high viscosities, Apollo® recommends that perforated screens without mesh liners be used. If mesh is required to obtain a certain level of filtration, then Apollo recommends a trapped perf./mesh/perf. combination. FILTRATION LEVEL When choosing...
Open the catalog to page 4FLANGED SERIES Y-STRAINERS engineering data - pressure drop (liquids) FEATURES & AVAILABILITY The following optional features are available for most Apollo Y-Strainers. Please consult factory if required feature not shown. Screen openings Screen materials Screen construction Standard coatings Perforated plate/mesh wire. 1. Strainer size may effect the ability to apply certain coatings and linings. 1. Pressure drop curves are based on water flow with standard screens. 2. See next page for correction factors to be used with other fluids and/or screen openings. For additional information, submittal...
Open the catalog to page 5FLANGED SERIES Y-STRAINERS engineering data - screen correction factor chart FOR NON-STANDARD AND MESH LINED SCREENS Chart #1 SCREEN OPENINGS Size Range 2" - 12" Perforated Plate % Screen Material Open Area 60% 0.65 Mesh Lined Standard Screens % Screen Material Open Area 50% 40% 30% 1.05 1.05 1.2 EXAMPLE Strainer Size: 2” Filtration: 100 Mesh lined Flow rate: 65 GPM Service: Water * Multiply values obtained from figure 1 thru 4 by the appropriate values shown below Notes: 1. See page 4 for % Open Area’s of Apollo inventoried perforated plate. 2. Standard screens for sizes 2” and larger is approximately...
Open the catalog to page 6FLANGED SERIES Y-STRAINERS engineering data - pressure drop (saturated steam) • Locate steam flow. • Follow horizontal line to required pressure. • Follow vertical line downwards to required strainer size. • Follow horizontal line to read pressure drop. • Pressure drop equals 2.0 psid. Notes: 1. Pressure drop curve is based on saturated steam flow with standard screens. See page 5 for correction factors to be used with other screen openings. 2. Chart can be used for air and gas by using the following formula: EXAMPLE Service: Saturated Steam Flow Pressure: 400 psig Steam Flow: 90,000 Lbs/hr Size:...
Open the catalog to page 7FLANGED SERIES Y-STRAINERS check list and suggested specifications STRAINER CHECK LIST When selecting a strainer, please take the factors listed below into account. This will assist us when recommending a strainer to suit your specific requirements. Please photocopy this page and fill out the pertinent information. SUGGESTED SPECIFICATIONS The strainer shall be a Y-Type and have __________________ (size) inlet/outlet connections. The end connections shall be flanged and the body shall be complete with a bolted cover assembly. The strainer shall be suitable for _____________ PSIG operating pressure...
Open the catalog to page 8FLANGED SERIES Y-STRAINERS installation and maintencance instructions STRAINER INSTALLATION INSTRUCTIONS A. B. C. D. E. Ensure all machined surfaces are free of defects and that the inside of the strainer is free of foreign objects. For horizontal pipelines, the strainer should be installed so that the drain connection is pointed downwards. For flanged end strainers, the flange bolting should be tightened gradually in a back and forth clockwise motion. Once installed, increase line pressure gradually and check for leakage around joints. If the strainer is supplied with a start-up screen, monitor...
Open the catalog to page 9FLANGED SERIES Y-STRAINERS engineering data - effective screen area Apollo Flanged Y-Strainer Order Schematic YCF MODEL YCF (Flat Face) VALVE TYPE/CONNECTION SIZE Flanged 2” = F02 Flanged 2.5” = F25 Flanged 3” = F03 Flanged 4” = F04 Flanged 5” = F05 Flanged 6” = F06 Flanged 8” = F08 Flanged 10” = F10 Flanged 12” = F12 NOTES: *All mesh screens are reinforced with a perforated liner. 2” - 3”: .045 Perf 4” - Larger: .125 Perf 10 SCREEN TYPE 20 Mesh = M20 40 Mesh = M40 80 Mesh = M80 100 Mesh = M100 .045 Perf = P045 .125 Perf = P125 COATING E Standard Epoxy Coating, FDA Approved
Open the catalog to page 10FLANGED SERIES Y-STRAINERS WARRANTY AND LIMITATIONS OF LIABILITY Conbraco Industries, Inc. warranties, to its initial purchaser only, that its products which are delivered to the initial purchaser will be of the kind described in the order or pricelist and will be free of defects in workmanship or material for a period of TWO years from the date of delivery to you, our initial purchaser. Should any failure to conform to this warranty appear within two years after the date of the initial delivery to our initial purchaser, Conbraco will, upon written notification thereof and substantiation that...
Open the catalog to page 1176 Pages
466 Pages
292 Pages
1 Page
2 Pages
3 Pages
5 Pages
2 Pages
28 Pages
28 Pages
76 Pages
16 Pages
68 Pages
4 Pages
5 Pages
5 Pages
3 Pages
4 Pages
32 Pages
44 Pages
184 Pages
20 Pages
44 Pages
52 Pages
20 Pages
12 Pages
71 Pages
312 Pages
20 Pages
20 Pages
12 Pages
1 Page
1 Page
1 Page
3 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
6 Pages
16 Pages
40 Pages
28 Pages
20 Pages
12 Pages
16 Pages
76 Pages
16 Pages
48 Pages
28 Pages
180 Pages
2 Pages
4 Pages
20 Pages
12 Pages
12 Pages
8 Pages
72 Pages
12 Pages
56 Pages
57 Pages
2 Pages
4 Pages
4 Pages
56 Pages
132 Pages
20 Pages