CS & CL SERIES ACTUATORS INTRODUCING SIMPLICITY FOR CALIBRATING MODULATING ACTUATORS The Control Board brings a whole new level of simplicity to the field. It will work with either of the Motor Boards (115VAC or 230VAC). Features include: • Switch selector for 4-20mA or 0-10VDC input • An adjustable pot for deadband adjustment • Switch selector for 4-20mA or 0-10VDC position readback • Locked Rotor Protection if the actuator cannot achieve the • Switch selector for either “fail in-place” or “fail to zero” upon loss position commanded by the control signal, it will cut power to the of control signal (provided input power remains) motor. Repeated stalls will not damage the actuator. • On-board push buttons to manually position the actuator • Reverse acting operation with no rewiring. • A “Mode Selector” switch with LEDs, which are used for: • Split range operation with no rewiring. - ”No tools” pot calibration - Setting Zero and Span - Manually positioning the actuator • An adjustable pot for Speed Control (motor pulsing)
Open the catalog to page 1CS & CL EXTENDED DUTY DATA TECHNICAL DATA-115VAC AND 230VAC MODELS* 1. The Current Draws stated above include all options. If the brake and/or heater & thermostat are not installed, the actual current draws will be less. 2. For Extended Duty Cycle Models, Current Draws are provided at full running torque. If the actuator encounters an overtorque condition, such as a stall condition, the Current Draw will be vastly increased. 3. Continuous Duty actuators contain brushless DC motors and are therefore not limited by duty cycle restraints in environments at or below 104°F; in ambient environments...
Open the catalog to page 21. All Continuous Duty Cycle CS/CL actuators accept any of the following input voltage (I2VDC, 24VDC, 24VAC, 1I5VAC, & 230VAC), are rated for continuous duty cycle, include a holding brake, two auxiliary limit switches, 4-20mA or 0-10VDCposition feedback, wrench-operated manual override, CSA “C US" certification, CE compliance, and a heater/thermostat that can be user-enabled on the option board. 2. Only one board option can (and must) be selected. All board options can be configured for On/Off or modulating operation. Customer Service (704) 841-6000 www.apolloflowcontrols.com
Open the catalog to page 376 Pages
466 Pages
292 Pages
1 Page
2 Pages
5 Pages
2 Pages
28 Pages
28 Pages
76 Pages
16 Pages
68 Pages
4 Pages
5 Pages
5 Pages
3 Pages
4 Pages
32 Pages
44 Pages
184 Pages
20 Pages
44 Pages
52 Pages
20 Pages
12 Pages
71 Pages
312 Pages
20 Pages
20 Pages
12 Pages
1 Page
1 Page
1 Page
3 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
6 Pages
16 Pages
40 Pages
28 Pages
20 Pages
12 Pages
16 Pages
76 Pages
16 Pages
48 Pages
28 Pages
180 Pages
2 Pages
4 Pages
20 Pages
12 Pages
12 Pages
8 Pages
72 Pages
12 Pages
56 Pages
57 Pages
2 Pages
4 Pages
4 Pages
56 Pages
132 Pages
20 Pages