Catalog excerpts
flanged series Y-strainers Engineering Data Screen Openings for Y-Strainers factors to consider purpose If the basket strainer is being used for protection rather than direct filtration, Apollo’s standard screens will suffice in most applications. service With services that require extremely sturdy screens, such as high pressure/ temperature applications or services with high viscosities, Apollo® recommends that perforated screens without mesh liners be used. If mesh is required to obtain a certain level of filtration, then Apollo recommends a trapped perf./mesh/perf. combination....
Open the catalog to page 4flanged series Y-strainers Engineering Data Y-Strainer Pressure Drop – Liquids features & availability The following optional features are available for most Apollo Y-Strainers. Please consult factory if required feature not shown. Feature Screen openings Screen materials Screen construction Gaskets Special body materials Special coatings Silicon free contamination Canadian Registration (CRN) Description of Availability Range 5 micron to 1/2” perf. Carbon steel, stainless steel (304/316 and L grades), alloy 20, monel 400, hastalloy C, Titanium, etc. Perforated plate, mesh and wedge wire....
Open the catalog to page 5flanged series Y-strainers Engineering Data Screen Correction Factor Chart for non-standard and mesh lined screens Chart #1 Screen Openings Size Range 2" - 16" Perforated Plate % Screen Material Open Area 60% 0.65 50% 0.8 40% 1 30% 1.4 20% 2.15 Mesh Lined Standard Screens % Screen Material Open Area 50% 40% 30% 1.05 1.05 1.2 example Strainer Size: Filtration: Flow rate: Service: 2” 100 Mesh lined 65 GPM Water * Multiply values obtained from figure 1 thru 4 by the appropriate values shown below Notes: 1. See page 4 for % Open Area’s of Apollo inventoried perforated plate. 2. Standard screens...
Open the catalog to page 6flanged series Y-strainers Engineering Data Y-Strainer Pressure Drop – Saturated Steam sizes 2” - 16” • Locate steam flow. • Follow horizontal line to required pressure. • Follow vertical line downwards to required strainer size. • Follow horizontal line to read pressure drop. • Pressure drop equals 2.0 psid. Notes: 1. Pressure drop curve is based on saturated steam flow with standard screens. See page 5 for correction factors to be used with other screen openings. 2. Chart can be used for air and gas by using the following formula: example Service: Pressure: Steam Flow: Size: where Qs =...
Open the catalog to page 7flanged series Y-strainers Check List and Suggested Specifications strainer check list When selecting a strainer, please take the factors listed below into account. This will assist us when recommending a strainer to suit your specific requirements. Please photocopy this page and fill out the pertinent information. suggested specifications The strainer shall be a Y-Type and have __________________ (size) inlet/outlet connections. The end connections shall be flanged and the body shall be complete with a bolted cover 1. Fluid to be strained ______________________________ assembly. The...
Open the catalog to page 8flanged series Y-strainers Installation and Maintenance Instructions strainer installation instructions A. B. C. D. E. Ensure all machined surfaces are free of defects and that the inside of the strainer is free of foreign objects. For horizontal pipelines, the strainer should be installed so that the drain connection is pointed downwards. For flanged end strainers, the flange bolting should be tightened gradually in a back and forth clockwise motion. Once installed, increase line pressure gradually and check for leakage around joints. If the strainer is supplied with a start-up screen,...
Open the catalog to page 9flanged series Y-strainers ENGINEERING DATA Y-Strainer Effective Screen Area Pipe Size (In.) Std. Opening (In.) 2 2-1/2 3 4 5 6 8 10 12 14 16 0.045 0.045 0.045 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 Series 125YF Nominal Area Gross Screen of Pipe Fitting Area (Sq. In.) (Sq. In.) 3.14 30.07 4.91 44.33 7.07 56.45 12.57 98.91 19.63 147.11 28.27 179.19 50.27 334.38 78.54 505.21 113.10 665.77 137.89 1186.34 182.65 1446.85 Free Area (Sq. In.) 10.82 15.96 20.32 39.56 58.85 71.68 133.75 202.08 266.31 474.54 578.74 Ratio Free Area to Pipe Area 3.45 3.25 2.88 3.15 3.00 2.54 2.66 2.57 2.35...
Open the catalog to page 10flanged series Y-strainers warrantY and limitations of liability Conbraco Industries, Inc. warranties, to its initial purchaser only, that its products which are delivered to the initial purchaser will be of the kind described in the order or pricelist and will be free of defects in workmanship or material for a period of TWO years from the date of delivery to you, our initial purchaser. Should any failure to conform to this warranty appear within two years after the date of the initial delivery to our initial purchaser, Conbraco will, upon written notification thereof and substantiation...
Open the catalog to page 11SALES & CUSTOMER SERVICE: Phone: (704) 841-6000 Fax: (704) 841-6020 www.apollovalves.com SOUTHEAST REGION Mid South Marketing, Inc. VA/MD/Washington, D.C./WV-East michael.uecker@msmsales1.com 804-213-3801 804-213-3802 Pro Marketing, Inc. NC/SC/TN-East sales@promarketinginc.net 864-578-4334 864-578-4889 Spirit Group FL (except Panhandle) info@spiritgroupinc.com 407-291-6035 407-299-0378 Tim Morales & Associates, Inc. AL/FL Panhandle sales@timmorales.com 251-602-8333 251-602-8339 White Wolf Group GA info@whitewolfgroupinc.com 800-401-4870 888-908-9372 SOUTHERN REGION BWC Inc. LA (Commercial...
Open the catalog to page 12All Conbraco Industries catalogs and technical brochures
-
Backflow Prevention
76 Pages
-
Industrial Products Binder
466 Pages
-
Actuation Catalog
57 Pages
-
Commercial Catalog
292 Pages
-
32-100 series
1 Pages
-
A108
2 Pages
-
CS & CL SERIES ACTUATORS
3 Pages
-
Actuators and Controls
5 Pages
-
Industrial Valve
2 Pages
-
Gate, Globe & Check Catalog
28 Pages
-
Class 600 Ball Valve
2 Pages
-
Butterfly Valves Catalog
28 Pages
-
Backflow Prevention Catalog 2016
76 Pages
-
Automatic Control Valves
16 Pages
-
APOLLOXPRESS CATALOG
68 Pages
-
APOLLOPEX Tools and Valves
4 Pages
-
Apollo ® Rack & Pinion
5 Pages
-
G series
5 Pages
-
LB series
3 Pages
-
CS, CL
4 Pages
-
PRODUCTS CATALOG
32 Pages
-
Top Entry Ball Valve Catalog
44 Pages
-
2014/2015 Commercial Catalog
184 Pages
-
WATER PRESSURE REDUCING VALVES
20 Pages
-
TOP ENTRY BALL VA LV ES
44 Pages
-
SAFETY AND RELIEF VALVES
52 Pages
-
MIXING VALVES
20 Pages
-
Marine Catalog
12 Pages
-
Lead Free Products Catalog
71 Pages
-
Industrial Ball Valve Binder Inserts
312 Pages
-
Fire Protection Products Catalog
20 Pages
-
Check Valve Brochure
20 Pages
-
Cast Iron Y-Strainer
12 Pages
-
77V series 1/2" - 2"
1 Pages
-
77V series 2-1/2" - 4"
1 Pages
-
77W-HC series
1 Pages
-
LB Series Electric Actuators
3 Pages
-
TEE
1 Pages
-
FEMALE ADAPTER
1 Pages
-
45 DEGREE ELBOW
1 Pages
-
MALE ADAPTER
1 Pages
-
Fitting Dimension Sheet
1 Pages
-
TS_acutorque_2
6 Pages
-
cat_PHBRWGA
16 Pages
-
cat_PHBRHYD
40 Pages
-
cat_GGC9000
28 Pages
-
cat_BFFPCAT
20 Pages
-
cat_ABBR141G
16 Pages
-
cat_AXCAT
76 Pages
-
cat_ACVBR9000
16 Pages
-
cat_ACCA9000
48 Pages
-
cat_CICA9000
28 Pages
-
cat_CPCA9000
180 Pages
-
SERIES 38-500
2 Pages
-
THREE-PIECE VALVES
4 Pages
-
pipeline strainers
20 Pages
-
MARINE VALVES AND FITTINGS
12 Pages
-
IN-LINE CHECK VALVES
12 Pages
-
CONTROL VALVES
8 Pages
-
BACKFLOW PREVENTERS
72 Pages
-
BALL VALVES
12 Pages
-
ACTUATORS AND CONTROLS
56 Pages
-
BALANCING VALVE (58 SERIES)
1 Pages
Archived catalogs
-
Actuation Catalog
56 Pages
-
AE Actuator
4 Pages
-
Class 600 Ball Valve
4 Pages
-
Conbraco - Catalog
132 Pages
-
Conbraco - Strainers CICASTOO
20 Pages