MedLine - 1

TEMPERATURE CONTROL UNITS - MEDLINE®4THERMOLATOR TW-P SERIES WATER TEMPERATURE CONTROLLER A Thermolator Designed for Medical Applications The MedLine® Thermolator TW-P Series is designed as the top-of-the-line Thermolator package. The MedLine TW-P offers extensive options for maintaining the process temperature with circulated water that has been heated or cooled to the required setpoint. All models offer incoloy heaters; silicon carbide pump seals; pressure gauges; easy-to-use microprocessor controls and tool-free access panels for fast removal. The MedLine TW-P offers options including: process line purge, a choice of temperature control points, auto re-start capability, a variety of communications options, cool down mode, remote start/stop, stainless steel exterior panels and a disconnect switch. Meets ISO Standards for Cleanroom Use Units are available in direct injection or closed circuit cooling; single-zone and dual-zone configurations. Pump sizes to 10 Hp per zone. Heaters to 48 kW per zone. Standard process temperatures to 250°F {121°C}, with a hightemperature option which increases the unit’s capacity to 300°F {149°C}. The MedLine® TW-P Thermolator is designed to offer every premium option available. Options can be included or excluded based on your desired configuration. Closed circuit units keep the process fluid separated from the cooling water, eliminating cross-contamination and allowing for the use of two different fluid sources. Calibrated to ISO standards The MedLine® TW-P Thermolator includes a quality and regulatory compliance package aligned with ISO, ICH, and FDA requirements. The Thermolator features RAL 9003 paint or stainless exterior construction, with materials suitable for ISO 14644 cleanrooms and associated controlled environments. RTD's calibrated to ISO 17025 standards. Energy savings Now with a 50% increase in the pump operating envelope, an application that may have previously required a 5 Hp pump may now only require a 2 Hp pump. PLUS, today’s pumps use less energy than their predecessors. Average yearly operating cost savings of the new Thermolators is $740 per unit. Higher-efficiency pumps More efficient pumps— 36% wire to water to be exact. Sizes from 3/4 Hp to 10 Hp, featuring silicon carbide seals and sediment traps for extended seal life. Pump volute and motor adapter have a 10 mil. powder coated Halar ECTFE finish with silicon brass impellers. `` Incoloy heaters Standard on all models, incoloy heaters resist damage from high temperature and chemicals, and are provided with a stainless steel flange plate. `` "Casters up" warranty Three full years on all MedLine Thermolator TW-P models, and a four-year warranty on the control.

Open the catalog to page 1
MedLine - 2

TEMPERATURE CONTROL UNITS - MEDLINE®4THERMOLATOR TW-P SERIES WATER TEMPERATURE CONTROLLER Features Incoloy heaters minimize chemical and high temperature damage. Three-piece cast construction eliminates potential leak points. Built-in pressure gauges are standard for all Conair TW Series Thermolators. High efficiency pumps from 3/4 to 10 Hp. Industry standard cast iron pump impellers on all models. Brass impellers for fluid path. Corrosion Resistance Package Protect components from damage with bronze or stainless external fittings, non-ferrous pump impellers, stainless steel heater flanges...

Open the catalog to page 2
MedLine - 3

TEMPERATURE CONTROL UNITS - MEDLINE®4THERMOLATOR TW-P SERIES WATER TEMPERATURE CONTROLLER Control Features Control Power Autostart Signal Pump Heat Cool Coolant Pressure Temperature Limit Flow GPM (flash) Electrical Phase Error Heat Error Process Cool Down Mold Purge Rapid Cool Process Cool Down Mold Purge Rapid Cool Communications Remote Heat/Cool Program Mode Model Direct Injection Closed Circuit - Common Source Closed Circuit - Separate Source Construction Standard Pump Range Standard Heater Range Cast Heater /Pump Incoloy Heaters Silicon Carbide Seals Pressure Gauges 250°F Setpoint...

Open the catalog to page 3
MedLine - 4

TEMPERATURE CONTROL UNITS - MEDLINE®4THERMOLATOR TW-P SERIES WATER TEMPERATURE CONTROLLER Specifications Models Performance Characteristics Minimum setpoint temperature °F {°C} Maximum setpoint temperature °F {°C} Minimum operating temperature °F {°C} Standard cooling valve size inches {mm} Available pump sizes Available heater sizes Connections to/from process NPT (female) Connections in/out cooling water NPT (female) Pump Performance - Consult your Conair representative for pump performance characteristics at other operating points. Pump Nominal flow gpm {lpm} Pressure@ nominal flow psi...

Open the catalog to page 4

All Conair catalogs and technical brochures

  1. 5000 Blender

    4 Pages

  2. TrueRate™

    3 Pages

  3. TrueWeigh

    6 Pages

  4. INTERMIXER

    2 Pages

  5. Dump Table

    2 Pages

  6. CPC Series

    4 Pages

  7. Medline

    6 Pages

  8. MEDVAC TANKS

    4 Pages

  9. HTR series

    4 Pages

  10. VTR

    4 Pages

  11. TW-V

    4 Pages

  12. TW-S

    4 Pages

  13. TW-P

    4 Pages

  14. TAC series

    2 Pages

  15. WELDED SILOS

    2 Pages

  16. HTMP SERIES

    4 Pages

  17. PTFG

    4 Pages

  18. CFC series

    2 Pages

  19. EP2

    8 Pages

  20. PTSS 0450

    4 Pages

  21. EP1

    6 Pages

  22. FLX-128

    4 Pages

  23. Bolted Silos

    2 Pages

  24. CH Hoppers

    4 Pages