Catalog excerpts
TEMPERATURE CONTROL UNITS - MEDLINE®4THERMOLATOR TW-P SERIES WATER TEMPERATURE CONTROLLER A Thermolator Designed for Medical Applications The MedLine® Thermolator TW-P Series is designed as the top-of-the-line Thermolator package. The MedLine TW-P offers extensive options for maintaining the process temperature with circulated water that has been heated or cooled to the required setpoint. All models offer incoloy heaters; silicon carbide pump seals; pressure gauges; easy-to-use microprocessor controls and tool-free access panels for fast removal. The MedLine TW-P offers options including: process line purge, a choice of temperature control points, auto re-start capability, a variety of communications options, cool down mode, remote start/stop, stainless steel exterior panels and a disconnect switch. Meets ISO Standards for Cleanroom Use Units are available in direct injection or closed circuit cooling; single-zone and dual-zone configurations. Pump sizes to 10 Hp per zone. Heaters to 48 kW per zone. Standard process temperatures to 250°F {121°C}, with a hightemperature option which increases the unit’s capacity to 300°F {149°C}. The MedLine® TW-P Thermolator is designed to offer every premium option available. Options can be included or excluded based on your desired configuration. Closed circuit units keep the process fluid separated from the cooling water, eliminating cross-contamination and allowing for the use of two different fluid sources. Calibrated to ISO standards The MedLine® TW-P Thermolator includes a quality and regulatory compliance package aligned with ISO, ICH, and FDA requirements. The Thermolator features RAL 9003 paint or stainless exterior construction, with materials suitable for ISO 14644 cleanrooms and associated controlled environments. RTD's calibrated to ISO 17025 standards. Energy savings Now with a 50% increase in the pump operating envelope, an application that may have previously required a 5 Hp pump may now only require a 2 Hp pump. PLUS, today’s pumps use less energy than their predecessors. Average yearly operating cost savings of the new Thermolators is $740 per unit. Higher-efficiency pumps More efficient pumps— 36% wire to water to be exact. Sizes from 3/4 Hp to 10 Hp, featuring silicon carbide seals and sediment traps for extended seal life. Pump volute and motor adapter have a 10 mil. powder coated Halar ECTFE finish with silicon brass impellers. `` Incoloy heaters Standard on all models, incoloy heaters resist damage from high temperature and chemicals, and are provided with a stainless steel flange plate. `` "Casters up" warranty Three full years on all MedLine Thermolator TW-P models, and a four-year warranty on the control.
Open the catalog to page 1TEMPERATURE CONTROL UNITS - MEDLINE®4THERMOLATOR TW-P SERIES WATER TEMPERATURE CONTROLLER Features Incoloy heaters minimize chemical and high temperature damage. Three-piece cast construction eliminates potential leak points. Built-in pressure gauges are standard for all Conair TW Series Thermolators. High efficiency pumps from 3/4 to 10 Hp. Industry standard cast iron pump impellers on all models. Brass impellers for fluid path. Corrosion Resistance Package Protect components from damage with bronze or stainless external fittings, non-ferrous pump impellers, stainless steel heater flanges...
Open the catalog to page 2TEMPERATURE CONTROL UNITS - MEDLINE®4THERMOLATOR TW-P SERIES WATER TEMPERATURE CONTROLLER Control Features Control Power Autostart Signal Pump Heat Cool Coolant Pressure Temperature Limit Flow GPM (flash) Electrical Phase Error Heat Error Process Cool Down Mold Purge Rapid Cool Process Cool Down Mold Purge Rapid Cool Communications Remote Heat/Cool Program Mode Model Direct Injection Closed Circuit - Common Source Closed Circuit - Separate Source Construction Standard Pump Range Standard Heater Range Cast Heater /Pump Incoloy Heaters Silicon Carbide Seals Pressure Gauges 250°F Setpoint...
Open the catalog to page 3TEMPERATURE CONTROL UNITS - MEDLINE®4THERMOLATOR TW-P SERIES WATER TEMPERATURE CONTROLLER Specifications Models Performance Characteristics Minimum setpoint temperature °F {°C} Maximum setpoint temperature °F {°C} Minimum operating temperature °F {°C} Standard cooling valve size inches {mm} Available pump sizes Available heater sizes Connections to/from process NPT (female) Connections in/out cooling water NPT (female) Pump Performance - Consult your Conair representative for pump performance characteristics at other operating points. Pump Nominal flow gpm {lpm} Pressure@ nominal flow psi...
Open the catalog to page 4All Conair catalogs and technical brochures
-
5000 Blender
4 Pages
-
CH SERIES INSULATED HOPPERS
4 Pages
-
HTC MODELS 600-5000
2 Pages
-
GASTRAC PROCESS AIR HEATER
2 Pages
-
MedLine® TrueFeed
4 Pages
-
TrueRate™
3 Pages
-
TrueWeigh
6 Pages
-
INTERMIXER
2 Pages
-
PET PREFORM SYSTEMS
12 Pages
-
TRUEBLEND ™ TB45-4
4 Pages
-
TRUEBLEND ™ TB100-4
4 Pages
-
Economy cooling tank
2 Pages
-
Heat Exchangers
11 Pages
-
medical tubing products
4 Pages
-
Water Pump Motors
1 Pages
-
Tower Isolation (PFT) Series
2 Pages
-
Film Scrap Granulators
4 Pages
-
Trim Pick-Up Inducers
2 Pages
-
ScrapSaver Fluff Feeder
2 Pages
-
TrueWeigh Continuous Blender
6 Pages
-
TrueWeigh Line Manager
2 Pages
-
TrueWeigh Hopper
2 Pages
-
Dump Table
2 Pages
-
ATC Series Coilers
2 Pages
-
CPC Series
4 Pages
-
Medline
6 Pages
-
TPC Planetary Cutter
2 Pages
-
CSC Series Cleated Puller
2 Pages
-
Precision Series Belt Puller
2 Pages
-
MCB Series Cooling Tank
2 Pages
-
MEDVAC TANKS
4 Pages
-
RESIN LEVEL DISPLAY
2 Pages
-
HTR series
4 Pages
-
VTR
4 Pages
-
TW-V
4 Pages
-
TW-S
4 Pages
-
TW-P
4 Pages
-
TrueWeigh Control TWC1-12
2 Pages
-
Equipment catalog
435 Pages
-
Parts and accessories
262 Pages
-
TAC series
2 Pages
-
CLEAN ROOM READY
6 Pages
-
WELDED SILOS
2 Pages
-
TrueWeigh Continous Blenders
6 Pages
-
TRUEFEED LIQUID FEEDER
2 Pages
-
Gaylord Tilters
2 Pages
-
Surge Bins, In-Plant
4 Pages
-
MT VACUUM SIZING TANKS
4 Pages
-
CBW GRANULATORS
2 Pages
-
Tube Loader (TLM)
2 Pages
-
HTMP SERIES
4 Pages
-
NC GRANULATORS
2 Pages
-
NCM GRANULATORS
2 Pages
-
TrueBlend? TB45
4 Pages
-
W Dryers (150-400)
4 Pages
-
W Dryers (15-100)
4 Pages
-
MICROWHEEL DRYERS
4 Pages
-
CAML-EVB Evacuation System
2 Pages
-
SCRAPSAVER (SSM)
2 Pages
-
MDCW (15-100)
4 Pages
-
THERMOLATOR® (TW) SERIES
4 Pages
-
MDCW (150-200)
4 Pages
-
PTFG
4 Pages
-
CFC series
2 Pages
-
EP2
8 Pages
-
PTSS 0450
4 Pages
-
EP1
6 Pages
-
TrueBlend? High Heat
4 Pages
-
TrueBlend? TB250
4 Pages
-
SlimLine (SL) Dryer
4 Pages
-
FLX-128
4 Pages
-
Powder Loader (PL)
2 Pages
-
Access? (AR) Receivers
4 Pages
-
CAML-EVG Evacuation System
2 Pages
-
Access? (AL) Loaders
4 Pages
-
Mobile Surge Bins
2 Pages
-
Bolted Silos
2 Pages
-
Spiral Aluminum Silos
2 Pages
-
GasTrac Process Air Heater
2 Pages
-
HTC Temperature Controller
2 Pages
-
Thermolator® vacuTrac
4 Pages
-
BP Series Belt Pullers
2 Pages
-
Pump Tank, Polymer
4 Pages
-
WSB/GB Retrofit Control
2 Pages
-
DM3-i Drying Monitor
2 Pages
-
ResinWorks System
4 Pages
-
BFS/BFH Metering Feeders
4 Pages
-
CH Hoppers
4 Pages
-
FL Filterless Receiver
2 Pages
-
Vacuum Railcar Unloading
2 Pages
-
Tube Loader (TLA)
2 Pages
-
FLX Loading Control
2 Pages
-
Silos, Spiral Steel
2 Pages
-
Dust Collectors (DC)
2 Pages
-
ELC Series Controls
4 Pages
-
MDCW Carousel Plus Dryer
115 Pages