Catalog excerpts

TPCX052-0811 CENTRAL VACUUM CONTROLS ELC-M AND ELC-16 MODELS VERSATILE CONTROLS FOR VACUUM CONVEYING The Easy Loading Control (ELC) from Conair offers a simple-touse interface for your conveying system. With the ELC, loading parameter setup can be accomplished with a few simple steps. Available with two application specific models, the ELC is capable of handling all your conveying needs. ELC-16 Control SIMPLE-TO-USE PENDANT FOR CONVEYING CONTROL The ELC is available as two models; the ELC-M and the ELC-16. The ELC-M is used for stand-alone hopper loader applications. The ELC-16 uses a CAN open network that allows up to 16 controls with receivers on one network cable, operated by a pump controller. The ELC’s optional ControlMate pendant uses the same type of intuitive interface as the ELC control, but allows the capability to change a total of 16 preset parameters to fine-tune your conveying needs. The ControlMate pendant can be used interchangeably with either the ELC-M or ELC-16 controls. The ELC will ship mounted and connected to your loader or receiver when purchased from Conair. Installation of your loader or receiver with the ELC is as simple as bolting it to your material vessel and connecting your power and/or communication cables. n Easy-to-read display Both the ELC control module and optional ControlMate pendant have clearly visible display panels. Loading sequence symbols and LED indicators display exactly where your loader or receiver is in the conveying process. n First-In/First-Out demand loading The ELC-16 control module comes standard with First-In/First-Out (FIFO) demand. Unlike earlier loading controls, the ELC-16 does not load receivers based on traditional demand loops. Instead, the receivers are loaded based on the order of demand for material. n Configure for priority receiver demand Use the optional ControlMate pendant to activate priority demand for your ELC16 control. This setting creates a second priority demand First-In/First-Out demand loop, that takes priority over the standard First-In/First-Out demand loop. n Interchangeable ControlMate pendant The addition of the optional ControlMate pendant allows the capability to alter up to 16 loading parameters for even more functionality. All loading changes are saved within the standard ELC module.
Open the catalog to page 1
CENTRAL VACUUM CONTROLS TPCX052-0811 ELC-M AND ELC-16 MODELS CONTROL MODELS ELC-16 control - A trunk cable supplies power and communications to up to 16 controls mounted on receivers from a central pump control via a CAN open network. ELC-M control - Used with a self-contained vacuum motor loader. The ELC-M is provided as standard with a three pronged power cable for easy installation. All ELC-16 controls are equipped with easy connections to the cables and junction boxes that make up the CAN open network. O P T I O N A L C O N T R O L M AT E P E N D A N T ELC ControlMateTM Pendant The...
Open the catalog to page 2
CENTRAL VACUUM CONTROLS TPCX052-0811 ELC-M AND ELC-16 MODELS HOW IT WORKS ELC-M Control A signal from the loader’s demand switch indicates to the ELC-M on the loader that it requires material to be conveyed to satisfy its demand. The ELC-M sends a signal to the vacuum motor on the loader to energize and start a loading cycle. The material is then drawn in by the loader’s vacuum motor. If the hopper is filled, the demand switch will remain open (Fig. 1) and no further load cycles are needed. However, if the demand was not satisfied and the demand switch closes (Fig. 2) the loader will...
Open the catalog to page 3
CENTRAL VACUUM CONTROLS TPCX052-0811 ELC-M AND ELC-16 MODELS S P E C I F I C AT I O N S 3 in. {76.2 mm} M5 Tapped A B C MODELS Supply voltage ELC-M ELC-16 CALCULATING ELC-16 SYSTEM CABLE LENGTH: 115VAC 50Hz, 230VAC 50/60Hz 24VDC (from pump control) Pump control voltage full load amps 230VAC/60Hz 400VAC/50Hz 460VAC/60Hz Control dimensions inches {mm} A - Height B - Width C - Depth Control weight lb {kg} Installed Shipping NA NA NA 0.64 0.37 0.32 4.5 {114.4} 6.0 {152.4} 2.9 {73.0} 4.5 {114.4} 6.0 {152.4} 2.9 {73.0} 7.6 {3.4} 9.1 {4.1} 7.6 {3.4} 9.1 {3.4} Total the distance from the vacuum...
Open the catalog to page 4All Conair catalogs and technical brochures
-
5000 Blender
4 Pages
-
CH SERIES INSULATED HOPPERS
4 Pages
-
HTC MODELS 600-5000
2 Pages
-
GASTRAC PROCESS AIR HEATER
2 Pages
-
MedLine® TrueFeed
4 Pages
-
MedLine
4 Pages
-
TrueRate™
3 Pages
-
TrueWeigh
6 Pages
-
INTERMIXER
2 Pages
-
PET PREFORM SYSTEMS
12 Pages
-
TRUEBLEND ™ TB45-4
4 Pages
-
TRUEBLEND ™ TB100-4
4 Pages
-
Economy cooling tank
2 Pages
-
Heat Exchangers
11 Pages
-
medical tubing products
4 Pages
-
Water Pump Motors
1 Pages
-
Tower Isolation (PFT) Series
2 Pages
-
Film Scrap Granulators
4 Pages
-
Trim Pick-Up Inducers
2 Pages
-
ScrapSaver Fluff Feeder
2 Pages
-
TrueWeigh Continuous Blender
6 Pages
-
TrueWeigh Line Manager
2 Pages
-
TrueWeigh Hopper
2 Pages
-
Dump Table
2 Pages
-
ATC Series Coilers
2 Pages
-
CPC Series
4 Pages
-
Medline
6 Pages
-
TPC Planetary Cutter
2 Pages
-
CSC Series Cleated Puller
2 Pages
-
Precision Series Belt Puller
2 Pages
-
MCB Series Cooling Tank
2 Pages
-
MEDVAC TANKS
4 Pages
-
RESIN LEVEL DISPLAY
2 Pages
-
HTR series
4 Pages
-
VTR
4 Pages
-
TW-V
4 Pages
-
TW-S
4 Pages
-
TW-P
4 Pages
-
TrueWeigh Control TWC1-12
2 Pages
-
Equipment catalog
435 Pages
-
Parts and accessories
262 Pages
-
TAC series
2 Pages
-
CLEAN ROOM READY
6 Pages
-
WELDED SILOS
2 Pages
-
TrueWeigh Continous Blenders
6 Pages
-
TRUEFEED LIQUID FEEDER
2 Pages
-
Gaylord Tilters
2 Pages
-
Surge Bins, In-Plant
4 Pages
-
MT VACUUM SIZING TANKS
4 Pages
-
CBW GRANULATORS
2 Pages
-
Tube Loader (TLM)
2 Pages
-
HTMP SERIES
4 Pages
-
NC GRANULATORS
2 Pages
-
NCM GRANULATORS
2 Pages
-
TrueBlend? TB45
4 Pages
-
W Dryers (150-400)
4 Pages
-
W Dryers (15-100)
4 Pages
-
MICROWHEEL DRYERS
4 Pages
-
CAML-EVB Evacuation System
2 Pages
-
SCRAPSAVER (SSM)
2 Pages
-
MDCW (15-100)
4 Pages
-
THERMOLATOR® (TW) SERIES
4 Pages
-
MDCW (150-200)
4 Pages
-
PTFG
4 Pages
-
CFC series
2 Pages
-
EP2
8 Pages
-
PTSS 0450
4 Pages
-
EP1
6 Pages
-
TrueBlend? High Heat
4 Pages
-
TrueBlend? TB250
4 Pages
-
SlimLine (SL) Dryer
4 Pages
-
FLX-128
4 Pages
-
Powder Loader (PL)
2 Pages
-
Access? (AR) Receivers
4 Pages
-
CAML-EVG Evacuation System
2 Pages
-
Access? (AL) Loaders
4 Pages
-
Mobile Surge Bins
2 Pages
-
Bolted Silos
2 Pages
-
Spiral Aluminum Silos
2 Pages
-
GasTrac Process Air Heater
2 Pages
-
HTC Temperature Controller
2 Pages
-
Thermolator® vacuTrac
4 Pages
-
BP Series Belt Pullers
2 Pages
-
Pump Tank, Polymer
4 Pages
-
WSB/GB Retrofit Control
2 Pages
-
DM3-i Drying Monitor
2 Pages
-
ResinWorks System
4 Pages
-
BFS/BFH Metering Feeders
4 Pages
-
CH Hoppers
4 Pages
-
FL Filterless Receiver
2 Pages
-
Vacuum Railcar Unloading
2 Pages
-
Tube Loader (TLA)
2 Pages
-
FLX Loading Control
2 Pages
-
Silos, Spiral Steel
2 Pages
-
Dust Collectors (DC)
2 Pages
-
MDCW Carousel Plus Dryer
115 Pages