1. Catalogs
  2. Conair
  3. ELC Series Controls
video corpo

ELC Series Controls

ELC Series Controls

ELC Series Controls

Product catalog summary
Overview
The document provides detailed information about the Easy Loading Control (ELC) systems, specifically the ELC-M and ELC-16 models, designed for vacuum conveying applications. These systems offer user-friendly interfaces and versatile control options for efficient material handling.

Specifications
The ELC systems are available in two models: ELC-M for standalone hopper loader applications and ELC-16 for networked systems using a CAN open network. The ELC-16 can manage up to 16 controls with receivers on a single network cable, operated by a pump controller. The systems are equipped with easy-to-read display panels and LED indicators to show the status of the conveying process.

Control Features
The ELC-16 control module supports First-In/First-Out (FIFO) demand loading, ensuring that material is delivered based on the order of demand rather than traditional demand loops. The optional ControlMate pendant allows for priority demand settings and can modify up to 16 loading parameters, enhancing functionality. The pendant is interchangeable between ELC-M and ELC-16 models.

Installation and Operation
The ELC systems are designed for easy installation, with the ELC-16 control using a trunk cable for power and communication. The systems are shipped pre-mounted and connected to the loader or receiver. The ControlMate pendant features a simple interface with LEDs, a numeric display, and push buttons for parameter adjustments.

Technical Specifications
The document includes detailed technical specifications for both ELC-M and ELC-16 models, including supply voltage, control dimensions, and weight. The ELC-16 system uses a 4-conductor trunk cable for network communication and is equipped with a pump control that provides power and communication signals.

Conclusion
The ELC systems from Conair offer a robust solution for vacuum conveying needs, with flexible control options and easy-to-use interfaces. The systems are designed to improve efficiency and adaptability in material handling processes.
See more

Catalog excerpts

ELC Series Controls-1

TPCX052-0811 CENTRAL VACUUM CONTROLS ELC-M AND ELC-16 MODELS VERSATILE CONTROLS FOR VACUUM CONVEYING The Easy Loading Control (ELC) from Conair offers a simple-touse interface for your conveying system. With the ELC, loading parameter setup can be accomplished with a few simple steps. Available with two application specific models, the ELC is capable of handling all your conveying needs. ELC-16 Control SIMPLE-TO-USE PENDANT FOR CONVEYING CONTROL The ELC is available as two models; the ELC-M and the ELC-16. The ELC-M is used for stand-alone hopper loader applications. The ELC-16 uses a CAN open network that allows up to 16 controls with receivers on one network cable, operated by a pump controller. The ELC’s optional ControlMate pendant uses the same type of intuitive interface as the ELC control, but allows the capability to change a total of 16 preset parameters to fine-tune your conveying needs. The ControlMate pendant can be used interchangeably with either the ELC-M or ELC-16 controls. The ELC will ship mounted and connected to your loader or receiver when purchased from Conair. Installation of your loader or receiver with the ELC is as simple as bolting it to your material vessel and connecting your power and/or communication cables. n Easy-to-read display Both the ELC control module and optional ControlMate pendant have clearly visible display panels. Loading sequence symbols and LED indicators display exactly where your loader or receiver is in the conveying process. n First-In/First-Out demand loading The ELC-16 control module comes standard with First-In/First-Out (FIFO) demand. Unlike earlier loading controls, the ELC-16 does not load receivers based on traditional demand loops. Instead, the receivers are loaded based on the order of demand for material. n Configure for priority receiver demand Use the optional ControlMate pendant to activate priority demand for your ELC16 control. This setting creates a second priority demand First-In/First-Out demand loop, that takes priority over the standard First-In/First-Out demand loop. n Interchangeable ControlMate pendant The addition of the optional ControlMate pendant allows the capability to alter up to 16 loading parameters for even more functionality. All loading changes are saved within the standard ELC module.

 Open the catalog to page 1
ELC Series Controls-2

CENTRAL VACUUM CONTROLS TPCX052-0811 ELC-M AND ELC-16 MODELS CONTROL MODELS ELC-16 control - A trunk cable supplies power and communications to up to 16 controls mounted on receivers from a central pump control via a CAN open network. ELC-M control - Used with a self-contained vacuum motor loader. The ELC-M is provided as standard with a three pronged power cable for easy installation. All ELC-16 controls are equipped with easy connections to the cables and junction boxes that make up the CAN open network. O P T I O N A L C O N T R O L M AT E P E N D A N T ELC ControlMateTM Pendant The ControlMate...

 Open the catalog to page 2
ELC Series Controls-3

CENTRAL VACUUM CONTROLS TPCX052-0811 ELC-M AND ELC-16 MODELS HOW IT WORKS ELC-M Control A signal from the loader’s demand switch indicates to the ELC-M on the loader that it requires material to be conveyed to satisfy its demand. The ELC-M sends a signal to the vacuum motor on the loader to energize and start a loading cycle. The material is then drawn in by the loader’s vacuum motor. If the hopper is filled, the demand switch will remain open (Fig. 1) and no further load cycles are needed. However, if the demand was not satisfied and the demand switch closes (Fig. 2) the loader will continue...

 Open the catalog to page 3
ELC Series Controls-4

CENTRAL VACUUM CONTROLS TPCX052-0811 ELC-M AND ELC-16 MODELS S P E C I F I C AT I O N S 3 in. {76.2 mm} M5 Tapped A B C MODELS Supply voltage ELC-M ELC-16 CALCULATING ELC-16 SYSTEM CABLE LENGTH: 115VAC 50Hz, 230VAC 50/60Hz 24VDC (from pump control) Pump control voltage full load amps 230VAC/60Hz 400VAC/50Hz 460VAC/60Hz Control dimensions inches {mm} A - Height B - Width C - Depth Control weight lb {kg} Installed Shipping NA NA NA 0.64 0.37 0.32 4.5 {114.4} 6.0 {152.4} 2.9 {73.0} 4.5 {114.4} 6.0 {152.4} 2.9 {73.0} 7.6 {3.4} 9.1 {4.1} 7.6 {3.4} 9.1 {3.4} Total the distance from the vacuum pump...

 Open the catalog to page 4

All Conair catalogs and technical brochures

  1. 5000 Blender

    4  Pages

  2. MedLine

    4  Pages

  3. TrueRate™

    3  Pages

  4. TrueWeigh

    6  Pages

  5. INTERMIXER

    2  Pages

  6. Heat Exchangers

    11  Pages

  7. Dump Table

    2  Pages

  8. CPC Series

    4  Pages

  9. Medline

    6  Pages

  10. MEDVAC TANKS

    4  Pages

  11. HTR series

    4  Pages

  12. VTR

    4  Pages

  13. TW-V

    4  Pages

  14. TW-S

    4  Pages

  15. TW-P

    4  Pages

  16. TAC series

    2  Pages

  17. WELDED SILOS

    2  Pages

  18. HTMP SERIES

    4  Pages

  19. MDCW (15-100)

    4  Pages

  20. PTFG

    4  Pages

  21. CFC series

    2  Pages

  22. EP2

    8  Pages

  23. PTSS 0450

    4  Pages

  24. EP1

    6  Pages

  25. FLX-128

    4  Pages

  26. Bolted Silos

    2  Pages

  27. CH Hoppers

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.