RI-01C Series Dry Reed Switch RI-01C Series Pico dry-reed switch hermetically sealed in a gas-filled envelope. Single-pole, single-throw (SPST) type, having normally open contacts, and containing two magnetically actuated reeds. The switch is of the double-ended type and may be actuated by an electromagnet, a permanent magnet or combination of both. The device is intended for use in senors, relays, pulse counters or similar devices. RI-01C Series Features ▪ Ideal for general purpose reed relays and sensors. ▪ Contact layers: ruthenium on gold ▪ Superior glass-to-metal seal and blade alignment ▪ RoHS Compliant Dimensions for RI-01C Series 0.906 ± 0.020 (23.0 ± 0.5) tinned All Dimension in inches (mm) nominal General data for all models RI-01C AT-Customization / Preformed Leads Besides the standard models, customized products can also be supplied offering the following options: • Operate and release ranges to customer specification • Cropped and/or preformed leads Coils All characteristics are measured using the Philips Standard Coil. For definitions of the Philips Standard Coil, refer to “Application Notes” in the Reed Switch Technical & Application Information Section of this catalog. Life expectancy and reliability The life expectancy data given below are valid for a coil energized at 1.25 times the published maximum operate value for each type in the RI-01C series. No load conditions (operating frequency: 100Hz) Life expectancy: min. 10 operations with a failure rate of less than 10-9 with a confidence level of 90%. End of life criteria: Contact resistance > 1Ω after 2 ms Release time > 2 ms (latching or contact sticking). 8 Loaded conditions (resistive load: 12 V; 4 mA; (15 mA peak); operating frequency: 170Hz) Life expectancy: min. 106 operations. End of life criteria: Contact resistance > 2Ω after 4 ms Release time > 0.7 ms (latching or contact sticking). Switching different loads involves different life expectancy and reliability data. Further information is available on request. Mechanical Data Contact arrangement is normally open; lead finish is tinned; net mass is approximately 100mg; and can be mounted in any position. Shock The switches are tested in accordance with “IEC 68-2-27”, test Ea (peak acceleration 150 G; half sinewave; duration 11ms). Such a shock will not cause an open switch (no magnetic field present) to close, nor a switch kept closed by an 80 AT coil to open.
Open the catalog to page 1The switches are tested in accordance with “IEC 68-2-6”, test Fc (acceleration 10G; below cross-over-frequency 57 to 62 Hz; amplitude 0.75 mm; frequency range 10 to 2000 Hz; duration 90 minutes.) Such a vibration will not cause an open switch ( no magnetic field present) to close, nor a switch kept closed by an 80 AT coil to open. Mounting The leads should not be bent closer than 1 mm to the glass-to-metal seals. Stress on the seals should be avoided Care must be taken to prevent stray magnetic fields from influencing the operating and measuring conditions. * The Contact Resistance is measured...
Open the catalog to page 2RI-01C Series Dry Reed Switch Comus International 454 Allwood Road Clifton, New Jersey 07012 U.S.A Comus Relays & Sensors 37 Thurber Boulevard, Suite 102 Smithfield, Rhode Island 02917 U.S.A Tel: (1)973 - 777 - 6900 Fax: (1)973 - 777 - 8405 email: [email protected] Website: http://www.comus-intl.com Comus Belgium BVBA Overhaamlaan 40 B-3700 Tongeren Belgium Comus Technology BV Jan Campertstraat 11 6416 SG Heerlen The Netherlands Tel: +33 (0)12 390400 Fax: +33 (0)12 235754 email: [email protected] Website: http://www.comus.be Tel: +31(0)45 5439345 Fax: +31(0)45 5427216 email: [email protected]...
Open the catalog to page 31 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
3 Pages
2 Pages
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
7 Pages
3 Pages
5 Pages
7 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
4 Pages
2 Pages
2 Pages
5 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
3 Pages
1 Page
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
3 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
3 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
2 Pages
1 Page
1 Page
5 Pages
3 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
10 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages