Pump units - 1

Pump units distribution systems for thermal power plant USE The PUMP UNITS optimize space and functionality in the heat station: their strengths are modularity, flexibility, the possibility of customization and an extremely compact and tidy design. They are available in three versions: • direct zone: high temperature • mixing fixed-point zone: with thermostatic valve adjustable between 30°C and 60°C • mixing modulating zone: with control unit and climatic regulation The PUMP UNITS are completed with manifold, separator and insulation to form a COMPARATO SYSTEM for thermal power stations. KEY FEATURES • Easy installation • Compact size • Adaptability to different types of plant • Full insulation • Design 9 Hot sanitary water recirculation Cold sanitary water Diacom MINI compensator Control unit External probe for climatic function DIRECT pump unit Room thermostat MIXING MODULATING pump unit MIXING FIXED-POINT pump unit

Open the catalog to page 1
Pump units - 2

Pump units VERSIONS AND CODES TYPE HIGH FLOW COOLING STANDARD HIGH FLOW Mixing fixed-point Mixing modulating PUMP UNITS WITH METER - VERSIONS AND CODES TYPE HEATING STANDARD COOLING READY FOR 1"X130mm PUMP Stub piece for meter DIRECT UNIT DIRECT UNIT REVERSED DIRECT UNIT REVERSED DIRECT UNIT WITH METER MIXING FIXED-POINT UNIT MIXING MODULATING UNIT REVERSED MIXING FIXED-POINT UNIT REVERSED MIXING MODULATING UNIT

Open the catalog to page 2
Pump units - 3

Pump units DIRECT PUMP UNITS The DIRECT pump units are able to provide the right flow rate and proper head to the heat transfer fluid in hydraulic circuits where the control of the delivery temperature is not necessary. Complete with high-efficiency pump, flow and return thermometers, system-side interception valves, non-return valve, shell insulation. The unit is reversible, in fact it is possible to reverse the flow from right to left, depending on the installation requirements. PRODUCT DESCRIPTION direct heating direct heating high head direct heating ready for 1"x130mm pump direct...

Open the catalog to page 3
Pump units - 4

Pump units TECHNICAL FEATURES PERFORMANCES Nominal diameter Maximum operating pressure Maximum temperature Minimum temperature Fluid type Maximum flow rate * Direct Direct high head COMPONENTS Pump High flow pump Check valve Thermometers Wilo Para 15/7 Wilo Para 25/9 integrated on the system return line 0-80°C USE Installation Room temperature Humidity DIMENSIONS AND WEIGHT External dimensions Empty weight with residual head of 20 kPa MATERIALS Pipes Shell insulation Pipe insulation ** copper Ø 22 mm EPP - density 45 kg/m^3 rubber-based foam elastomer 6 mm polyethylene foam Insulating...

Open the catalog to page 4
Pump units - 5

Pump units MIXING FIXED-POINT PUMP UNITS The mixing fixed-point pump units are able to provide the right flow rate and proper head to the heat transfer fluid in hydraulic circuits where the control of the FIXED-POINT delivery temperature is necessary. Complete with high-efficiency pump, flow and return thermometers, system-side interception valves, non-return valve, mixing thermostatic valve, shell insulation. Temperature range adjustable between 30°C and 60°C. The unit is reversible, in fact it is possible to reverse the flow from right to left, depending on the installation requirements....

Open the catalog to page 5
Pump units - 6

Pump units TECHNICAL FEATURES PERFORMANCES Nominal diameter Maximum operating pressure Maximum temperature Minimum temperature Fluid type Maximum flow * Mixing fixed-point Mixing fixed-point high head COMPONENTS Pump High flow pump Check valve Thermometers Thermostatic mixer setpoint Thermostatic mixer Kv Accuracy with residual head of 20 kPa Wilo Para 15/7 Wilo Para 25/9 integrated on the system return line 0-80°C 30-60°C 3 m^3/h +/- 2°C ** at inlet temperature 15°C above setpoint HYDRAULIC CONNECTIONS Material System side Boiler/manifold side Span USE Installation Room temperature...

Open the catalog to page 6
Pump units - 7

Pump units MIXING MODULATING PUMP UNITS The mixing modulating pump units are able to provide the right flow rate and proper head to the heat transfer fluid in hydraulic circuits where the control of the MODULATING delivery temperature is required. Complete with high-efficiency pump, flow and return thermometers, system-side interception valves, non-return valve, motorised mixing valve, shell insulation. With the addition of SINTESI or SINTESI SMART actuator (accessories) and an electronic temperature controller, it is possible to have a precise and reliable control. In combination with the...

Open the catalog to page 7
Pump units - 8

Pump units TECHNICAL FEATURES PERFORMANCES Nominal diameter Maximum operating pressure Maximum temperature Minimum temperature Fluid type Maximum flow * mixed rate mixed high head COMPONENTS Pump High flow pump Check valve Thermometers Mixer ball valve Kv mixing valve Actuator USE Installation Room temperature Humidity DIMENSIONS AND WEIGHT External dimensions Empty weight Wilo Para 15/7 Wilo Para 25/9 integrated on the system return line 0-80°C 3-way 11 m^3/h see accessories with residual head of 20 kPa MATERIALS Pipes Shell insulation Pipe insulation ** copper Ø 22mm EPP - density 45...

Open the catalog to page 8
Pump units - 9

Pump units ACCESSORIES FOR MIXING MODULATING PUMP UNITS TECHNICAL FEATURES Electric control 3-point Connection to the ball valve fast push connection Rotation 90° Operating time 35 s 120 s Position indicator rotating arrow Power supply 230V 50/60 Hz Power consumption 3,9 VA Microswitch closed position                          (mixing valve oriented toward system return) Microswitch power output 1 A resistive - 250 V Protection degree IP54 Cable length 80 cm For the installation of SINTESI 3-POINT MODULATING actuators on inverted pump units (system flow to the left and system return to the...

Open the catalog to page 9
Pump units - 10

Pump units CONTROL UNIT for radiant panels with actuator The electronic control unit, equipped with actuator and delivery temperature probe, regulates and manages heating and cooling systems * with floor, wall or ceiling radiant panels. Once installed, it is possible to select the type of operation, enabling or disabling the various functions. code CGRMS1 • management of 1 modulating zone * for cooling a GR1MFR or GR2MFR pump unit is necessary Fixed-point regulation The heating setpoint temperature is set via the keypad and display. The room thermostat is activated by the room thermostat...

Open the catalog to page 10