Catalog excerpts
ROTARY ACTUATORS - ISO 5211 CONNECTION USE systems using alternative energy automation systems glycol cooling systems heating/cooling systems open and closed hydraulic systems industrial systems using hot and cold fluids drinking water systems, with suitable ball valve water treatment systems compressed air systems KEY FEATURES innovative “ALL IN ONE” control IP67 degree of electrical protection extra microswitches in opening and closing position manual override from the top different operating times TECHNICAL FEATURES Electric control Connection with ball valve ON/OFF • Modulating Compatible ball valves Position indicator Arrow on the lever for manual opening Bidirectional - synchronous Power supply Electrical connection Internal terminal block Nominal torque Operating time for 90° (seconds) Maximum power consumption Flow rate of outlet phase to terminals 4 and 5 Maximum noise (at 1 meter distance) Power output of extra micros Operational room temperature Fluid temperature See features of ball valves Protection degree External covering Glass-filled “polyarylamide” technopolymer Material of external metal components and seals AISI 303 GVR and brass CW617N • silicone seals * per le UNIVERSAL PRO le versioni DIAMANT PRO 4 sec e 12 sec la versione 60Hz è disponibile a richiesta • ** versione standard
Open the catalog to page 1ROTARY ACTUATORS - ISO 5211 CONNECTION VERSIONS Actuator Rotation angle Operating time Power supply Base code ACCESSORIES You can add any accessory to the actuators of the by adding or removing items from the base code. Manual override from the top * remove A = Not present Operating times Q = 4 sec (90°) D = 12 sec (90°) C8 = 106 sec (90°) 32 = 320 sec (90°) Heating resistance STARTING base code Manual override from the top * SA = Not present Operating times 9 = Heating resistance STARTING base code * only available with standard operating time
Open the catalog to page 2ROTARY ACTUATORS - ISO 5211 CONNECTION Manual override from the top SA = Not present Operating times S = Heating resistance R = Present STARTING base code ELECTRICAL CONNECTIONS With the electrical ALL IN ONE control, you can select the 2-POINT control or the 3-POINT control by moving the selector (jumper) mounted on the electrical circuit inside the actuator. 2-POINT CONTROL • ON/OFF (SWITCH) One electric control can activate several actuators. OPENING ACTUATOR CLOSING ACTUATOR - Neutral - Closing phase - Opening phase - Outlet opening phase - Outlet closing phase - Auxiliary micro in...
Open the catalog to page 3ROTARY ACTUATORS - ISO 5211 CONNECTION 3-POINT CONTROL • MODULATING Each actuator must be operated by a single electric control OPENING ACTUATOR INTERMEDIATE POSITION CLOSING ACTUATOR Position the jumper as shown in the picture to have the desired electrical connection 1 2 3 - Neutral - Closing phase - Opening phase - Outlet opening phase - Outlet closing phase M1 - Auxiliary micro in opening position M2 - Auxiliary micro in closing position A - Switch-type control - Earth AUXILIARY MICROSWITCHES The layout of the extra microswitch contacts is shown in the following pictures: M1 • OPENING...
Open the catalog to page 4ROTARY ACTUATORS - ISO 5211 CONNECTION MANUAL OPERATION The manual override allows to activate the valve in case of emergency or black-out. For Compact PRO the manual opening is only available for standard operating times. Actuator in OPENING position. Actuator in CLOSING position. Press the release button (a) and, simultaneously, rotate the lever (b) 90° COUNTERCLOCKWISE, in order to move the actuator in the CLOSING position. Press the release button (a) and, simultaneously, rotate the lever (b) 90° CLOCKWISE, in order to move the actuator in the OPENING position. When you release the...
Open the catalog to page 5ROTARY ACTUATORS - ISO 5211 CONNECTION CONNECTION TO THE BALL VALVE DIRECT CONNECTION TO THE VALVE PRO Range actuator Ball valve Panel adapter (if necessary) CONNECTION TO THE BALL VALVE WITH A SPACER On Compact PRO and Universal PRO motorized valves, the insulation spacer can be added by adding “D1” to the end of the assembly code. For the use of the insulation spacer (or spacer with manual opening) with Diamant PRO actuators, please refer to the "Diamant PRO Comparato connection - DP0.0-20". Compact PRO / Universal PRO Ball valve Panel adapter (if necessary) Spacer for insulation
Open the catalog to page 6ROTARY ACTUATORS - ISO 5211 CONNECTION OVERALL SIZE ACTUATORS version WITHOUT manual override from the top version WITHOUT manual override from the top version WITHOUT manual override from the top SPACERS SPACERS FOR INSULATION Part code Part code To be combined with actuators without manual top opening only Add "D1" to end of motorized valve code
Open the catalog to page 7ROTARY ACTUATORS - ISO 5211 CONNECTION BALL VALVE ASSIGNMENT - LISTED COUPLINGS 3-way BRASS “T”- port “L”- port 3-way BRASS Mixing Diverting COMPARATO CONNECTION 2-way BUTTERFLY FLANGED BALL VALVE cast iron COMPACT PRO COMPACT PRO UNIVERSAL PRO Other combinations on request EXAMPLE OF SPECIFICATIONS DIAMANT PRO ISO ACTUATOR • ALL IN ONE (2-point ON/OFF or 3-point ON/OFF or 3-point modulating), nominal torque: 11 Nm, power supply: 230V - 50/60 Hz, operating times: 35 sec / 90°, operating angle: 90°, protection degree: IP67, for ball valve: 2 - 3 way, connection to ball valve via ISO 5211...
Open the catalog to page 8All Comparato Nello S.r.l. catalogs and technical brochures
-
Industrial Catalogue
108 Pages
-
General Catalogue
204 Pages
-
SINTESI actuator
4 Pages
-
SINTESI DC actuator
4 Pages
-
SINSTESI SMART actuator
4 Pages
-
SINTESI MODBUS actuator
4 Pages
-
SINTESI brass ball valve
6 Pages
-
DIAMANT 2000 actuator
6 Pages
-
DIAMANT PRO IP67 actuator
6 Pages
-
DIAMANT PRO brass ball valve
8 Pages
-
MIX RANGE mixing valve
6 Pages
-
MIX PLUS RANGE mixing valve
8 Pages
-
ECOPOOL pool regulation kit
2 Pages
-
PILOT multifunction actuator
8 Pages
-
PRO RANGE IP67 DC actuator
4 Pages
-
PRO RANGE PCV ball valve
6 Pages
-
PRO RANGE butterfly valve
4 Pages
-
UNIVERSAL motorized valve
6 Pages
-
UNDER-BOILER units
6 Pages
-
Safety device holders
2 Pages
-
Pump units
18 Pages
-
Deaerators
2 Pages
-
DIASYS manifold-separators
2 Pages
-
DIASEP air separators
4 Pages
-
DIADEF deposit separators
4 Pages
-
DIACOM hydraulic separators
4 Pages
-
DIACOL manifolds
8 Pages