MIX L RANGE antilegionella mixing valve
8Pages

{{requestButtons}}

Catalog excerpts

MIX L RANGE antilegionella mixing valve - 1

Diamix L - Compamix L MIXING/THERMOREGULATING MOTORISED VALVES FOR DOMESTIC HOT WATER WITH ANTI-LEGIONELLA FUNCTION USE Domestic hot water mixing in plants with recirculation, where it is necessary to carry out a programmed thermal disinfection according to the national guidelines for the prevention and control of legionellosis. FUNCTIONS domestic hot water mixing programmable disinfection thermal cycle completed cycle storage Comparato's LegioTool software for PC communication and mixing valve with data download remote management with Modbus RTU protocol recirculation return temperature regulation with Pulse-Width Modulation (PWM) of the pump recirculation pump hourly schedule Diamix L APPLICATIONS blocks of flats offices hospitals and nursing homes sports centers (swimming pools, gyms…) hotels and campsites shopping centers TECHNICAL FEATURES Power supply (110V on request) Maximum power consumption Operating time (90° rotation) Protection degree Operational room temperature Fluid type Domestic water Fluid temperature Temperature probes Electronic adjuster Temperature adjustment field Disinfection cycle programming Daily / weekly Serial interface Communication protocol Clock battery Lithium CR2032, 10 years life Recirculation pump relay flow rate Pump modulating signal Digital inputs Disinfection cycle activation • Forcing towards hot • Forcing towards cold Digital outputs Active Disinfection Cycle • Disinfection Cycle Alarm (max 24Vdc 50mA) Cable length Conformity of ball valves

Open the catalog to page 1
MIX L RANGE antilegionella mixing valve - 2

Diamix L - Compamix L MIXING/THERMOREGULATING MOTORISED VALVES FOR DOMESTIC HOT WATER WITH ANTI-LEGIONELLA FUNCTION VERSIONS The codes shown refer to the basic 230V version, for a 24V 50/60Hz supply voltage, please add “04” at the end of the code. Δp max KvS [m3/h] [bar] * with unions Note: in order for the mixing process to run properly, make sure that the pressure values at the two inlets of the mixing valve are as constant and similar as possible. FLOW RATES Diamix L DN 15 1/2" MINIMUM FLOW MAXIMUM FLOW * [l/min] SIZING CRITERIA Caution! For a proper operation, you need to choose the...

Open the catalog to page 2
MIX L RANGE antilegionella mixing valve - 3

Diamix L - Compamix L MIXING/THERMOREGULATING MOTORISED VALVES FOR DOMESTIC HOT WATER WITH ANTI-LEGIONELLA FUNCTION EXAMPLE OF USE A A : Domestic hot water B : Domestic hot water recirculation C : Domestic cold water DOMESTIC COLD WATER DIAMIX L / COMPAMIX L mixing valve Buffer tank Recirculation pump Recirculation temperature probe 5 : Mixed temperature probe 6 : Expansion vessel 7 : Domestic hot water boiler BUFFER TANK If necessary, it is possible to mount a buffer tank (2) on the outlet pipeline. This will avoid any fluctuation of the reference temperature value when the drawing flow is...

Open the catalog to page 3
MIX L RANGE antilegionella mixing valve - 4

Diamix L - Compamix L MIXING/THERMOREGULATING MOTORISED VALVES FOR DOMESTIC HOT WATER WITH ANTI-LEGIONELLA FUNCTION DISINFECTION CYCLE ALARMS If the hot water temperature is not high enough (temperature below 55°C for 60 minutes) the alarm “ALbt” is activated, the cycle fails and the regulator automatically resumes the mixing function. If there is no power supply, the “ALd” alarm is activated, the cycle fails and the regulator automatically resumes the mixing function. The disinfection cycle can not last more than 300 minutes: if the cycle does not finish in time, the “ALot” alarm is...

Open the catalog to page 4
MIX L RANGE antilegionella mixing valve - 5

Diamix L - Compamix L MIXING/THERMOREGULATING MOTORISED VALVES FOR DOMESTIC HOT WATER WITH ANTI-LEGIONELLA FUNCTION REMOTE MANAGEMENT – RTU MODBUS and Compamix L are equipped with RTU MODBUS interface and it is possible to modify all the operating parameters, send commands to the valve, receive information on the operating status and download the data of the stored thermal disinfection cycles using the RS485 serial connection. Diamix L and Compamix L mixing valves are suitable for connection with modern Building Management Systems (BMS). The Modbus address table can be downloaded from...

Open the catalog to page 5
MIX L RANGE antilegionella mixing valve - 6

Diamix L - Compamix L MIXING/THERMOREGULATING MOTORISED VALVES FOR DOMESTIC HOT WATER WITH ANTI-LEGIONELLA FUNCTION ASSEMBLY NOTES: The pipe section where the temperature probe will be placed must be made of metal. The following part of the pipe can be of any type, provided it is suitable to the use. Once the ball valve has been installed, the actuator can be rotated 180°. Mounting the actuator facing downwards is not allowed. Position the check valve on the recirculation pump outlet. INSTALLATION The valve should be installed in such a way that the actuator connection is not facing...

Open the catalog to page 6
MIX L RANGE antilegionella mixing valve - 7

Diamix L - Compamix L MIXING/THERMOREGULATING MOTORISED VALVES FOR DOMESTIC HOT WATER WITH ANTI-LEGIONELLA FUNCTION OVERALL SIZE COMPARATO connection OVERALL SIZE • BALL VALVES BALL VALVES D - E: dimensions referred to the ball valve without unions VERTICAL mixed COMPARATO connection Diamix L COMPARATO connection Diamix L ISO 5211 connection Diamix L ISO 5211 connection Diamix L ISO 5211 connection VERTICAL mixed ISO 5211 connection Compamix L Compamix L Compamix L ACCESSORIES INSULATION SPACER • Add "D1" to the end of the code ball valve with COMPARATO connection ball valve with ISO 5211...

Open the catalog to page 7
MIX L RANGE antilegionella mixing valve - 8

Diamix L - Compamix L MIXING/THERMOREGULATING VALVES FOR DOMESTIC HOT WATER WITH ANTI-LEGIONELLA FUNCTION ACCESSORIES BRASS IMMERSION PROBE WITH CONNECTOR • Add "K" to the end of the code NOTE: socket not included RS485-USB INTERFACE • Code USBMOD Code USBMOD EXAMPLE OF SPECIFICATIONS DIAMIX L MIXING MOTORISED VALVE: ANTI-LEGIONELLA • electronic PID regulator, domestic hot water mixing, programmable thermal disinfection cycle, data storage of completed cycle, recirculation pump hour scheduling, remote management with Modbus-RTU protocol, adjustment range: 30°C ÷ 65°C, accuracy: ±1°C,...

Open the catalog to page 8