Overview: The DIATECH S is a hydraulic interface unit (HIU) designed for centralized heating systems, providing instant domestic hot water through a plate heat exchanger. It can be installed either wall-mounted or built into a wall, with connections for both the centralized system and the housing unit.
Main Features:
  • Instant domestic hot water production.
  • Independent management and cost breakdown based on actual consumption.
  • Energy-saving capabilities and total security.
  • Compatibility with pre-heated water from solar systems.
Specifications:
  • Certified under UNI EN ISO 9001:2015.
  • Includes hydraulic connections for treated/pre-heated water inlets, domestic hot water outlets, and heating connections.
  • Flow coefficient (kv) and pressure drop calculations are provided.
Functionality:
  • Heating Function: Utilizes a 2-way ON/OFF SINTESI motorized valve controlled by a room thermostat for fluid interception and flow rate adjustment.
  • Domestic Hot Water Production: Controlled by a PID electronic regulation system, ensuring precise temperature maintenance.
Electrical Connections:
  • Details on M-bus line and room thermostat connections.
  • Power supply requirements: 230V, 50Hz.
Installation:
  • Designed for indoor installation in frost-protected rooms.
  • Options for wall-mounted or flush-mounted installations.
  • Installation must be vertical with specific hydraulic connection guidelines.
Technical Features:
  • Material specifications for hydraulic holder, shell, frame, and piping.
  • Maximum temperature and pressure ratings for heating and domestic hot water circuits.
  • Flow rates and volumetric meter specifications provided.
Optional Components:
  • Domestic recirculation line with pump.
  • Various balancing valves and electronic flow control options.
Warranty: Effective from the date of testing or purchase, lasting 24 months.
Communication System: The document describes a cabled communication system for peripheral metering units and a remote control unit, which collects consumption data accessible directly on the control unit display, via a PC, or remotely through a modem interface.
Certifications: The system complies with several CE directives, including the Machinery Directive 2006/42/CE, Low Voltage Directive 2014/35/UE, and Electromagnetic Compatibility Directive 2014/30/UE. The company is UNI EN ISO 9001:2015 certified.
System Specifications: The DIATECH S Hydraulic Interface Unit is designed for centralized heating systems with instant domestic hot water production. It features a PID-controlled electronic regulation system and motorized valves. Key components include a plate heat exchanger, flow meter, and control panel with digital display. The system supports a maximum pressure of 6 bar and temperature of 90°C, with a nominal power of 41 kW.
Installation and Electrical Details: The unit requires a 230V - 50Hz power supply with a maximum consumption of 10 W. It supports flush-mounted installation with a template case and includes electrical connections for power supply, room thermostat, and M-bus line.
Additional Components: The document lists additional components such as the DIATECH LF Template Case, frame and door with custom lock, and various meters including an M-bus heating energy meter and a volumetric meter.
Contact Information: For further information, the document advises contacting the Technical Office of Comparato Nello S.r.l.
See more

Catalog excerpts

DIATECH S hydraulic interface unit-1

Metering, heating and production of domestic hot water DESCRIPTION DIATECH S is a hydraulic interface unit (HIU) for the management and direct calculation in centralised heating systems with instant production of domestic hot water by means of a plate heat exchanger. The installation can be wall-mounted, with or without a shell, or built-into wall in a template case. The plant connections are opposed: the upper ones towards the centralised system and the lower ones towards the housing unit. DIATECH S is able to use the pre-heated domestic water coming from a solar heating system, supplying only the necessary amount of energy. • Domestic hot water production • Management independence • Costs breakdown according to real consumptions • Total security • Energy saving HEATING OUTLET HEATING RETURN COLD NETWORK WATER DOMESTIC HOT WATER DOMESTIC TREATED WATER DOMESTIC HOT WATER RECIRCULATION HOUSING UNIT HEATING SYSTEM DOMESTIC UNITS THERMOSTATIC VALVE HOUSING UNIT ROOM THERMOSTAT DIATECH S TECHNICAL ROOM FOR CONDENSING GENERATORS, SEE THE DIATECH LF SATELLITE MODULE DOMESTIC WATER SOFTENER

 Open the catalog to page 1
DIATECH S hydraulic interface unit-2

Manual shut-off valve (version with template housing) MID-approved impulsive volumetric domestic water meter * Pump unit (optional) MID-approved M-bus energy counter * Temperature probe for domestic hot water Flow meter Stainless steel braze welded plate exchanger Built-in check valve (optional) 2-way modulating SINTESI motorised valve, domestic water 2-way ON/OFF SINTESI motorised valve, heating Y-strainer Balance valve (static / dynamic / DPCV / electronic option) Control panel Domestic hot water recirculation pump (optional) UPPER CONNECTIONS Centralised system side Treated and/or pre-heated...

 Open the catalog to page 2
DIATECH S hydraulic interface unit-3

S FUNCTION HEATING FUNCTION: The DIATECH S units allow the interception of the fluid by means of a 2-way ON/OFF SINTESI motorised valve controlled by the room thermostat (not included) and the adjustment of the flow rate via the balance valve. Valves are available for static balance, dynamic balance and differential pressure control or electronic system for Modflow rate control. DOMESTIC HOT WATER PRODUCTION: DIATECH S controls the instantaneous domestic hot water production by means of a three-action electronic regulation system (PID). The contact probe detects the temperature of the hot water...

 Open the catalog to page 3
DIATECH S hydraulic interface unit-4

S TECHNICAL FEATURES ENERGY METER Type mechanical (1 ) Flow rate Qp 1,5 m3/h Minimum flow 0,015 m3/h Maximum flow 3,0 m3/h DN 15 PN 16 Power supply lithium battery Class protection IP54 Interface M-bus (2 ) Certification MID VOLUMETRIC METER FOR DOMESTIC WATER Type mechanical Permanent flow rate Q 1,5 m3/h Minimum flow 0,03 m3/h Maximum flow 3,0 m3/h DN 15 PN 16 Interface pulse output Certification MID MOTORISED VALVES Type ON/OFF (90°) heating - 15 sec Modulating type (90°) domestic - 15 sec DHW ELECTRONIC CONTROL SYSTEM Type PID algorithm Dead band ±1°C Display approximation 1°C Adjustment...

 Open the catalog to page 4
DIATECH S hydraulic interface unit-5

S HIU CONFIGURATION FLOW REGULATOR 1 TREATED WATER LINE PUMP WITH REPLACEMENT STUB PIECE of the treated water meter DOMESTIC RECIRCULATION LINE WITH PUMP It keeps the recirculation loop warm in the housing unit 4 LINE INSTALLATION BASIC With shell If not necessary PUMP It allows the relaunch of the primary fluid in the apartment without using the prevalence of the centralised plant pump STATIC BALANCING VALVE It allows the flow rates to be manually balanced using a calibrated knob until they reach the design values necessary for the good operation of the system DYNAMIC BALANCING VALVE Automatically...

 Open the catalog to page 5
DIATECH S hydraulic interface unit-6

S VERSIONS AND CODE BUILDER DS E.g.: Wall-mounted DIATECH S with shell and pump unit on primary circuit 0 DOMESTIC TREATED AND/OR PREHEATED LINE 0 = not required T = treated water meter replacement stub piece B = base (with no shell), optional template case W = wall-mounted with shell PUMP 0 P 8 9 not required pump unit on primary circuit sanitary recirculation pump unit on primary and domestic recirculation 0 = not required J = static balancing valve X = dynamic balancing valve D = differential Pressure Control Valve (DPCV) M = Modflow - electronic flow control INSTALLATION The DIATECH S HIU...

 Open the catalog to page 6
DIATECH S hydraulic interface unit-7

S INSTALLATION WARNING It is advisable to use flexible hydraulic connection in order to compensate for any thermal expansion and possible misalignment between the system connections. WARRANTY AND FIRST START-UP The warranty becomes effective on the date of testing, if required, and shall last for 24 months. If testing is not required, the warranty will become effective on the date of purchase. M-BUS SYSTEM : M-bus data acquisition control unit : Control unit-PC connection : Control unit-modem connection : Concentrator nodes The M-bus system represents a cabled means of communication among the...

 Open the catalog to page 7
DIATECH S hydraulic interface unit-8

S OVERALL SIZE WALL-MOUNTED TEMPLATE CASE for FLUSH-MOUNTED version version with NO SHELL WALL-MOUNTED version with SHELL EXAMPLE OF SPECIFICATIONS DIATECH S HYDRAULIC INTERFACE UNIT for the management and direct metering in centralised heating systems with instant production of domestic hot water by means of a plate heat exchanger. Domestic hot water production controlled by a pre-set three-action electronic regulation system (PID) and a motorised regulation valve on the primary circuit of the exchanger. Main components: • Replacement stub piece for domestic water meter • Replacement stub piece...