Catalog excerpts
Diamant 2000 ISO FEMALE BRASS MOTORISED BALL VALVES - REDUCED PORT USE zone heating/cooling systems (HVAC) systems using alternative energy household automation systems KEY FEATURES ALL IN ONE electric control IP65 degree of electrical protection extra opening and closing microswitches (optional) manual override from the top (optional) different operating times (optional) TECHNICAL FEATURES OF THE ACTUATOR Electric control Connection to the ball valve Modulating • ON/OFF Bidirectional synchronous Power supply Electrical connection Internal terminal block Rated torque Maximum power consumption Power output on the outlet phase to terminals 4 and 5 Maximum noise (at 1 meter distance) Additional micro power output Operational room temperature Fluid temperature See features of ball valves Protection degree External covering Polycarbonate lid • glass-filled technopolymer base Material of external metal components and seals AISI 303 GVR • silicone seals * for the 4-sec and 12-sec versions, the 60Hz version it is available on request • ** standard version VERSIONS • The codes below refer to the 230V 50/60 Hz version for the standard operating time of 35 sec for 90°. Actuator Operating time Power supply Base code
Open the catalog to page 1Diamant 2000 ISO FEMALE BRASS MOTORISED BALL VALVES - REDUCED PORT ACCESSORIES To add any accessory, proceed as per the diagram below, adding one or more corresponding items to the desired accessory a at the end of the Base Code. Power supply 1 = Extra microswitch in opening position Extra microswitch in opening and closing position Manual override from the top A = Present available for 35-sec standard version only STARTING base code ELECTRICAL CONNECTIONS With the electrical ALL IN ONE control, you can select the 2-POINT control or the 3-POINT control by moving the selector (jumper)...
Open the catalog to page 2Diamant 2000 ISO FEMALE BRASS MOTORISED BALL VALVES - REDUCED PORT 3-POINT CONTROL • ON/OFF Each actuator must be operated by a single electric control OPENING ACTUATOR CLOSING ACTUATOR - Neutral - Closing phase - Opening phase - Outlet opening phase - Outlet closing phase - Auxiliary micro in opening position M2 - Auxiliary micro in closing position A - Switch-type control - Earth Place the jumper as shown in the picture to have the desired electrical connection 3-POINT CONTROL • MODULATING Each actuator must be operated by a single electric control OPENING ACTUATOR INTERMEDIATE POSITION...
Open the catalog to page 3Diamant 2000 ISO VALVOLE MOTORIZZATE A SFERA IN OTTONE FEMMINA - PASSAGGIO RIDOTTO EXAMPLES OF ELECTRICAL CONNECTIONS CONNECTION OF THE PUMP STOP WITH TWO 3-POINT ACTUATOR Control contact CONNECTION OF THE PUMP STOP WITH TWO 2-POINT ACTUATOR Control contact Control contact Control contact CONNECTION OF THE PUMP STOP WITH A 2-POINT ACTUATOR AND A 3-POINT ACTUATOR 2-POINT Control contact MANUAL OPERATION Only available for Diamant 2000 ISO with 35-second operating time. The manual override allows to activate the valve in case of emergency or black-out. a Actuator in OPENING position. Actuator...
Open the catalog to page 4Diamant 2000 ISO FEMALE BRASS MOTORISED BALL VALVES - REDUCED PORT CONNECTION TO THE BALL VALVE For the evaluation of the overall size of motorised valves, take into account the assembling diagram (shown below) and the dimensions of each single component. Diamant 2000 ISO 5211 connection Ball valve Squared adapter (if necessary) TECHNICAL FEATURES OF THE BALL VALVES Fluid type Fluid temperature Rated pressure Characteristic curve Operating angle 2-WAY BALL VALVE The ball valve can be mounted in both flow directions, without distinction. OPEN valve CLOSED valve OPENING ACTUATOR FLOW RATE...
Open the catalog to page 5Diamant 2000 ISO FEMALE BRASS MOTORISED BALL VALVES - REDUCED PORT 3-WAY BALL VALVE – DIVERTING Diamant 2000 ISO 3-way ball valve with partial bore are available with T-port and can be used for realizing a diverting action. During the operation the actuator closes one way and in the meantime opens the other way: all three ways communicate with each other. Despite the condition stated above, the control during mixing can be realized ONLY in T3-T2 position. DIVERTING BALL VALVE – T-PORT Diverting ball valve with “T”-port is characterized by a ball which can be used in different ways according...
Open the catalog to page 6Diamant 2000 ISO FEMALE BRASS MOTORISED BALL VALVES - REDUCED PORT 3-WAY FF BRASS ISO 5211 BALL VALVE 1 BRASS CW 617N - UNI EN 12420 / CHROMED NICKEL BRASS CW 617N - UNI EN 12420 / NICKEL PLATING BALL SEAL BALL SEAL ANTI-FRICTION SEAL ANTI-FRICTION SEAL OVERALL SIZE Diamant 2000 ISO 5211 connection Version with MANUAL OVERRIDE FROM THE TOP OVERALL SIZE BALL VALVES BRASS MODEL
Open the catalog to page 7Diamant 2000 ISO FEMALE BRASS MOTORISED BALL VALVES - REDUCED PORT EXAMPLE OF SPECIFICATIONS DIAMANT 2000 MOTORISED VALVE • 3-way female with reduced port, made up of: DIAMANT 2000 ISO actuator ALL IN ONE 2-point ON/OFF and 3-point ON/OFF or modulating, power supply: 230V - 50/60 Hz, operating time: 35 sec / 90°, operating angle: 90°, degree of protection: IP65; brass ball valve CW617N UNI EN 12420, PTFE seals, EPDM O-rings, PN16, max ΔP 3,4 bar, reduced port, female thread EN 10226-1, operating temperatures +5°C…+100°C. Fluid type water with glycol max 30%. Version: 3-way FFF DN50 – Rp 2"...
Open the catalog to page 8All Comparato Nello S.r.l. catalogs and technical brochures
-
Industrial Catalogue
108 Pages
-
General Catalogue
204 Pages
-
SINTESI actuator
4 Pages
-
SINTESI DC actuator
4 Pages
-
SINSTESI SMART actuator
4 Pages
-
SINTESI MODBUS actuator
4 Pages
-
SINTESI brass ball valve
6 Pages
-
DIAMANT 2000 actuator
6 Pages
-
DIAMANT PRO IP67 actuator
6 Pages
-
DIAMANT PRO brass ball valve
8 Pages
-
MIX RANGE mixing valve
6 Pages
-
MIX PLUS RANGE mixing valve
8 Pages
-
ECOPOOL pool regulation kit
2 Pages
-
PILOT multifunction actuator
8 Pages
-
PRO RANGE IP67 DC actuator
4 Pages
-
PRO RANGE PCV ball valve
6 Pages
-
PRO RANGE butterfly valve
4 Pages
-
UNIVERSAL motorized valve
6 Pages
-
UNDER-BOILER units
6 Pages
-
Safety device holders
2 Pages
-
Pump units
18 Pages
-
Deaerators
2 Pages
-
DIASYS manifold-separators
2 Pages
-
DIASEP air separators
4 Pages
-
DIADEF deposit separators
4 Pages
-
DIACOM hydraulic separators
4 Pages
-
DIACOL manifolds
8 Pages