NFPA Cylinder
24Pages

{{requestButtons}}

Catalog excerpts

NFPA Cylinder - 2

www.itt-tie-rod-cylinders.com • Customer Service: 864-647-9521 • Fax: 864-647-9574

Open the catalog to page 2
NFPA Cylinder - 3

Pneumatic Tie Rod Cylinder Overview Pneumatic Tie Rods • Stainless steel material prevents corrosion Piston Rod • High strength, precision chrome plated steel • Superior wear resistance • Stainless steel rod available Tube • High strength hard anodized aluminum • Superior wear resistance (optional) Enersorb® Piston (Patented) • Innovative design integrates seal, wear band, magnet and bumpers into one component • High Energy Absorption • Bumpers reduce noise more than 50% Rod Seal • Bubble tight carboxilated nitrile seal Head, Cap & Retainer • High strength anodized aluminum Cushions •...

Open the catalog to page 3
NFPA Cylinder - 4

How to Order - Pneumatic Tie Rod Interchangeable Cylinders TIE ROD SERIES MOUNT TYPE STROKE (INCHES) 1/2 Bore Cylinder Bore Cylinder 1/2 Bore Cylinder 1/4 Bore Cylinder Bore Cylinder Single End, Std Rod Size Single End, Ovs Rod Size Double End, Std Rod Size Double End, Ovs Rod Size See Rod Size and Thread Style Chart for description. CUSHION TYPE PORT TYPE Specify Stroke to Two Decimal Places* Example 1 1/4" = 1.25 Standard Stroke Tolerance ±.031 No Cushion Cushion Both Ends 1&5 Cushion Both Ends 2 & 6 (STD) Cushion Both Ends 3&7 Cushion Both Ends 4&8 Cushion Cap End 5 Cushion Cap End 6...

Open the catalog to page 4
NFPA Cylinder - 5

Basic No Mount MX0 BASIC NO MOUNT (SINGLE ROD END) MX0 BASIC NO MOUNT (SINGLE ROD) MX0 BASIC NO MOUNT (DOUBLE ROD END) Only mounts available for double rod end are: MF1, MS1, MS4, MTI, MT4, MXØ, MX1 and MX3. G G LD + STROKE LD + STROKE ZM + (2 X STROKE) ZM + (2 X STROKE) Rod End Styles STANDARD MALE ROD END (STYLE #1) *STANDARD MALE ROD END OVERSIZE MALE ROD END (STYLE #2) D ACROSS FLATS D ACROSS FLATS CC THREAD AD KK THREAD KK THREAD MM MM ROD DIA. ROD DIA. NA FLAT TURN DOWN FLAT TURN DOWN A A FEMALE ROD END (STYLE #3) KK THREAD KK THREAD A DEEP A DEEP *Note: Male Rod Ends are threaded Rod...

Open the catalog to page 5
NFPA Cylinder - 6

Flange and Trunnion Mounts MF1 FRONT FLANGE MOUNT THRU FOR FB BOLT 4 PLACES MF2 REAR FLANGE MOUNT THRU FOR FB BOLT 4 PLACES MT1 HEAD TRUNNION MOUNT www.itt-tie-rod-cylinders.com • Customer Service: 864-647-9521 • Fax: 864-647-9574

Open the catalog to page 6
NFPA Cylinder - 7

Clevis, Eye and Angle Mounts MP1 CLEVIS MOUNT Pin included with mount. MP2 DETACHABLE CLEVIS MOUNT Pin included with mount. Pin included with mount. MS1 ANGLE MOUNT XA + STROKE S THRU FOR AB BOLT 6 PLACES www.itt-tie-rod-cylinders.com • Customer Service: 864-647-9521 • Fax: 864-647-9574

Open the catalog to page 7
NFPA Cylinder - 8

Side Lug, Bottom Tap and Pneumatic Tie Rod Mounts MS2 SIDE LUG MOUNT THRU FOR SB BOLT 4 PLACES (Same for Single and Double Rod End) MX1 BOTH EXTENDED TIE ROD MOUNT MX2 CAP EXTENDED TIE ROD MOUNT MX3 HEAD EXTENDED TIE ROD MOUNT www.itt-tie-rod-cylinders.com • Customer Service: 864-647-9521 • Fax: 864-647-9574

Open the catalog to page 8
NFPA Cylinder - 9

Clevis Brackets THRU FOR DD BOLT 4 PLACES DD THREAD THRU 4 PLACES ROD STUD AND STEP STUD B 2xA www.itt-tie-rod-cylinders.com • Customer Service: 864-647-9521 • Fax: 864-647-9574

Open the catalog to page 9
NFPA Cylinder - 10

Rod Diameter Selection Cylinder thrust load, mounting style and stroke are the three main factors in determining rod diameter. Cylinder thrust loads can be determined from the max usable cylinder extend force charts on page 3. The mounting style can be determined using the drawings below. Once the thrust load, mounting style and stroke are known, the rod diameter chart can be used to determine the rod diameter. Example: • 2 1/2 inch cylinder bore 80 psi air pressure • MF1 mount with Rod Clevis 60 inch stroke From the rod diameter chart 5/8" rod diameter has a load rating of 122 pounds 1"...

Open the catalog to page 10
NFPA Cylinder - 11

Dual Piston Selection Dual Pistons (two pistons with a spacer in between) are needed in some cylinders with long strokes. The purpose of a dual piston is to prevent binding or jack-knifing. Below is a chart that shows dual piston length in relation to mounting style (from previous page) and stroke. DUAL PISTON CHART Stroke Length 20" 25" 30" 40" 50" Minimum Dual Piston Length Mounting Style #1 0 0 0 0 0 Approximate Cylinder Weight Chart (lbs.) D A E ACROSS FLATS KK THREAD G ACROSS FLATS ØF SHANK (1/16" RADIAL FLOAT) (1º SPHERICAL FLOAT) Sensor information is available on page 21....

Open the catalog to page 11
NFPA Cylinder - 12

How to Order: Pneumatic Tie Rod Pin-Act Cylinder (1 1/2" to 4" Bore) NFPA Shot Pin Cylinder Rear Flange Mount Front Flange Mount THREAD STYLE PORT TYPE CUSHION TYPE STROKE (inches) MOUNT TYPE BORE SIZE Cushion Both Ends Angle Mount Cushion Both Ends 2 & 6 (STD)N Cushion Both Ends *NOTE: 3-1/4” and 4” bore only. Cushion Both Ends Both Extended Tie Rod Mount Specify Stroke to Two Decimal Places* Single End, Standard Rod Size* Single End, Oversize Rod Size Double End, Standard Rod Size* Double End, Oversize Rod Size Standard Stroke Tolerance +/-.031 N *Consult Factory above 4.00 inches stroke....

Open the catalog to page 12
NFPA Cylinder - 13

Basic Dimensions (X0 Mount) The basic mounting (X0) is shown below; however other mounting styles are available. Special note: F1, S1, X1 mounts are added to the bearing block face. P Dimensional Specifications Bore Rod End Styles D ACROSS FLATS NOTE: See page 4 for Rod End Styles #1, #2 and #3. Cone Point Styles PB www.itt-tie-rod-cylinders.com • Customer Service: 864-647-9521 • Fax: 864-647-9574

Open the catalog to page 13
NFPA Cylinder - 14

Flange and Angle Mounts F1 FRONT FLANGE MOUNT UF TF THRU FOR FB BOLT 4 PLACES F2 REAR FLANGE MOUNT ZF + STROKE UF TF THRU FOR FB BOLT 4 PLACES S1 ANGLE MOUNT XA + STROKE C THRU FOR AB BOLT TYPICAL 6 PLACES Dimensional Specifications Bore www.itt-tie-rod-cylinders.com • Customer Service: 864-647-9521 • Fax: 864-647-9574

Open the catalog to page 14
NFPA Cylinder - 15

Side Lug, Bottom Tap and Pneumatic Tie Rod Mounts S2 SIDE LUG MOUNT THRU FOR SB BOLT 4 PLACES NT THREAD TK DEEP TYPICAL 4 PLACES X1 BOTH ENDS EXTENDED TIE RODS X2 CAP EXTENDED TIE RODS X3 HEAD EXTENDED TIE RODS DD THREAD Dimensional Specifications Bore 1 1/2 Sensor information is available on page 21. www.itt-tie-rod-cylinders.com • Customer Service: 864-647-9521 • Fax: 864-647-9574

Open the catalog to page 15

All Compact Automation Products catalogs and technical brochures