1. Catalogs
  2. COMET
  3. MXR-450XP/15/20-20

MXR-450XP/15/20-20

MXR-450XP/15/20-20

MXR-450XP/15/20-20

Product catalog summary
Product Description
The MXR-450XP/15/20-20 is a bipolar oil-cooled X-ray tube assembly designed for non-destructive imaging applications. It features a dual focal spot design, a high power tungsten anode, and a directional beam, with integrated radiation protection.
General Information
The integrator is responsible for controlling high-voltage, tube current, and filament current, as well as the cooling system and radiation protection. Proper settings in the generator are crucial to prevent damage from overcurrent, overvoltage, or inadequate cooling. Compliance with local regulatory requirements for radiation protection is mandatory, and any modifications to the product will void the warranty.
Connection and Cooling
High-voltage cables should be installed by trained personnel, ensuring cleanliness, correct greasing, and pressure. The cooling circuit must be properly connected and monitored, with the coolant flow continuing for at least two minutes after the tube is switched off to prevent overheating.
Product Specifications
  • Nominal tube voltage: 450 kV
  • Continuous and maximum cyclic rating: 1800 W
  • Focal spot size: 2.0 mm
  • Filament current, max: 4.6 A
  • Filament voltage, typical: 2.8 V
  • Inherent filtration: 3.0 mm + 2.0 mm Be
  • Target material: Tungsten (W)
  • Target angle: 15°
  • Radiation coverage: 40° x 30°
  • Leakage radiation: Max 10 mSv/h at 1m distance
  • Weight: 105 kg
  • Terminal type: R28
  • Cooling medium: Oil, with a minimum flow of 14 l/min and max inlet temperature of 50°C
  • Pressure at cooling medium inlet: Max 10 bar
  • Dielectric strength of insulating oil: ≥ 20kV/mm
  • Recommended insulating/cooling oil: Shell Diala S4 ZX-I
  • Post-cooling time: Minimum 2 minutes
See more

Catalog excerpts

MXR-450XP/15/20-20-1

X-Ray Tubes MXR-450XP/15/20-20 Product Description The MXR-450XP/15/20-20 is a bipolar oilcooled X-ray tube assembly with integrated radiation protection. It comprises a dual focal spot design, a high power tungsten anode and a directional beam. The tube is specifically designed for non-destructive imaging applications. Power rating chart Power rating at a given filament current mA 12 10 8 6 4 2 0 0

 Open the catalog to page 1
MXR-450XP/15/20-20-2

Product Specifications Nominal tube voltage Continuous rating (non-cyclic) Focal spot acc. ASTM E1165-12 Filament voltage, typical Inherent filtration Target material Target angle Radiation coverage Leakage radiation, max. ar loading factors in 1m distance PTB Type Approval Weight Terminal type Gapping spring-loaded HV-cable Gapping non-spring-loaded HV-cable Grease quantity for HV-cable terminal Product No. 3.0 mm + 2.0 mm Be W 15° 40° x 30° 10 mSv/h (450 kV; 4 mA) 105 kg R28 2 rings visible (~ 7 mm) 5.5 - 6 mm 1.4 ml 915431.51 General The control of high-voltage, tube current and filament current...

 Open the catalog to page 2

All COMET catalogs and technical brochures

  1. MesoFocus

    4  Pages

  2. EVO 300P

    2  Pages

  3. EVO 160D

    2  Pages

  4. EVO 200D

    2  Pages

  5. EVO 225D

    2  Pages

  6. EVO 225DS

    2  Pages

  7. EVO 300D

    2  Pages

  8. EVO 300DS

    2  Pages

  9. EVO 225D/1200

    2  Pages

  10. EVO 300D/1200

    2  Pages

  11. CONTROL EVO

    2  Pages

  12. ION Series

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.