WebSensors with Ethernet output and relay Catalog
5Pages

{{requestButtons}}

Catalog excerpts

WebSensors with Ethernet output and  relay Catalog - 1

TEMPERATURE AND ENVIRONMENT MONITORING MONITORE * CONTROL * ALERT RECORD * ANALYZE A Solution For every need and every budget Offers built-in temperature and humidity sensors and allows external detectors to be added

Open the catalog to page 1
WebSensors with Ethernet output and  relay Catalog - 2

Rack mounted design Monitor temperature, humidity, CO2, flood, power, smoke, room entry allows unlimited alerts notification; notification via emails and internet protocols; allows automatic shutdowns data sorage in CSV file or in the Comet Database software based on MS SQL Wall mounted design For more information visit www.cometsystem.com Button for deactivation of audible Comet Database software offers: Three inputs for detector connection- dry contact, open collector, two-state voltage signal. Temperature and humidity sensor smoke detector flood detector data stored in one place and...

Open the catalog to page 2
WebSensors with Ethernet output and  relay Catalog - 3

IF you want to intagrate Web Sensor to your system Mounting accessories For more information visit www.cometsystem.com ModbusTCP protocol Modbus protocol for communication with SCADA systems or third party software. Device use version of Modbus TCP protocol. SNMP protocol SNMP version 1 protocol for ^infrastructure. Using SNMP protocol you can read actual measured values, alarm statuses and alarm parameters. MIB tables with OID description are available. SNMP Trap SNMP Trap for IT infrastructure. The device allows sending Traps to selected Trap receiver server. Traps are sent in case of...

Open the catalog to page 3
WebSensors with Ethernet output and  relay Catalog - 4

Remote controling Chart with historical value Export measured value to file General device sellings Settings Alarm limits activated when measured value exceed* set value return* back with hyttere*is. Temnet attire limits with a selected time delay. Alarm h cleared If measured Baste settings ol the network Alarm limits I imlleuration nt the alarm Relative humidity limits Aierm i Disabled Hulls, ilisplay st-Uinos. rli Alarm 2 i owor than limit Settings Inputs Rlnary Input* setting*. Alarm* on binary Input* are evaluated by the selected alarm Temperature 26.0°C alarm 1 active alarm 2 none...

Open the catalog to page 4
WebSensors with Ethernet output and  relay Catalog - 5

COMET SYSTEM, s.r.o. Bezrucova 2901 756 61 Roznov pod Radhostem CZECH REPUBLIC Tel: +420-571653990 Fax: +420-571653993 E-mail: info@cometsystem.com www.cometsystem.com Catalogue COMET - temperature and environment monitoring 08/2017 TEMPERATURE AND ENVIRONMENT MONITORING

Open the catalog to page 5