1. Catalogs
  2. Comeco Control & Measurement
  3. electrochemical, pressure, and flow transducers

electrochemical, pressure, and flow transducers

electrochemical, pressure, and flow transducers

Product catalog summary
Overview: This document provides technical specifications for various industrial-grade transmitters and switches, including pH/ORP preamplifiers, dissolved oxygen transmitters, pressure transmitters, flow switches, and CO2 transmitters. Each product is detailed with its operational parameters, suitable applications, and key features.
1. pH/ORP Preamplifiers:
  • PHA100: A low-cost preamplifier with bipolar power supply, suitable for pH and ORP measurements in liquids. It operates within 0...60 °C and offers an accuracy of 0.01% of span. It requires a ±5...±8 VDC power supply and has no temperature compensation.
  • PHA150: Features unipolar power supply and temperature compensation, operating from 0...70 °C. It provides an accuracy of 0.05% of span and requires a 5...9 VDC power supply.
2. pH/ORP Transmitter:
  • PHT: Offers low-voltage or mains power supply options, with an operating range of 0...60 °C. It supports pH and ORP measurements with an accuracy of 0.05% of span and includes temperature compensation.
3. Dissolved Oxygen Transmitter:
  • PHO2: Designed for fluids with dissolved O2, operating from 0...55 °C. It provides an accuracy of 1% of span and includes temperature compensation. Compatible with various O2 probes.
4. Pressure Transmitters:
  • PSP: Industrial-grade gauge and absolute pressure transmitter, suitable for non-aggressive fluids. It operates from -40...105 °C with an accuracy of 0.5% or 0.25% of span.
  • PSQ: A low-cost gauge-pressure transmitter for non-aggressive fluids, operating from -40...85 °C with an accuracy of 1...4% of span.
  • PSX PSQA PSF21x: Ex-rated gauge and absolute pressure transmitter, operating from -40...85 °C with an accuracy of 0.5% or 0.25% of span.
5. Flow Switches and Meters:
  • PSF50: Paddle flow switch suitable for low-viscosity liquids, operating from -40...85 °C with an accuracy of 25% of span.
  • PSF20x: Flow meter/transmitter with digital display, suitable for clear and translucent liquids, operating from -10...65 °C with an accuracy of 1% of span.
  • PSF100: Thermal flow switch for low-viscosity liquids, operating from -10...65 °C with an accuracy of 10% of span.
6. CO2 Transmitter:
  • PHG: Designed for air, operating from 0...50 °C with an accuracy of 2 ppm. Suitable for food industry applications with a local display option.
Key Features: The document highlights critical parameters such as operating temperature, protection class, accuracy, power supply requirements, and connectivity options for each product. It also notes specific applications and compatibility with various probes and sensors.
See more

Catalog excerpts

electrochemical, pressure, and flow transducers-1

PSF100 thermal flow switch low-cost pH/ORP preamplifier with bipolar power supply pH/ORP preamplifier pH/ORP transmitter with unipolar power supply with low-voltage and temperature or mains power supply compensation CO2 transmitter with digital display dissolved-oxygen transmitter industrial-grade with temperature gauge- and compensation absolute-pressure transmitter Ex industrial-grade gauge- and absolute-pressure transmitter low-cost industrial-grade gauge-pressure transmitter low-cost industrial-grade gauge-pressure transmitter with digital display paddle flow switch Medium Type fluids with dissolved O2 non-aggressive fluids, compatible with sensor non-aggressive fluids, compatible with sensor non-aggressive fluids, compatible with sensor non-aggressive fluids, compatible with sensor clear and translucent liquids, clear and translucent liquids, low-viscosity liquids, low-viscosity liquids, 1...1000 CST compatible with wetted parts compatible with wetted parts 1...1000 CST Sensor / Input pH or ORP probe with combined electrodes pH or ORP probe with combined electrodes; Pt100 CO2 NDIR incorporated sensor Poly-Si- on SiO2 thin-film resistance Poly-Si- on SiO2 thin-film resistance Poly-Si- on SiO2 thin-film resistance Poly-Si- on SiO2 thin-film resistance paddle-operated magnet switch thermal dispersion between two RTD sensors light-weight rotor light-weight rotor PSPR: -1...max. 1000 bar PSPA: 0...max. 100 bar; according to EN ranges PSXR: -1...max. 2000 bar PSXA: 0...max. 100 bar; according to EN ranges water: ≈ 0.01...1.5 m/s oil: ≈ 0.02...3 m/s temperature: medium Medium Temp. Medium Pressure depends on probe flow meter / transmitter with digital display flow controller with digital display relay 2A/230VAC/50W; contact: NO/NC relay 3A/250VAC; contact: NO/NC polarization ON/OFF switch none paddle length trimpots, rotary switch Power Supply Wetted Parts stainless steel stainless steel stainless steel stainless steel stainless steel stainless steel free or flange (duct) Ambient Temp. input: BNC connector output: screw terminals input: BNC connector output: screw terminals input: BNC connector or screw terminals output: screw terminals plug-in terminals screw terminals screw terminals no temperature compensation; all output data at 25 °C temperature compensation with Pt100 external sensor available; all output data at 25 °C exact input range must be specified in customer order; all output data at 25 °C suitable for food industry applications; local display and sintered filter available PSPR: for gauge pressure operates with SENSOREX, INGOLD, PSPA: for absolute pressure and other compatible O2 probes suitable for 1...3" pipes; operates in both flow directions; Ex version available response time of only 15 s; suitable for water treatment suitable for water treatment applications; applications; Ex version available chemically resistant variant chemically resistant variant PSXR: for gauge pressure suitable for water treatment alarm relay output available PSXA: for absolute pressure applications

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.