InfraMİX Series Premix Gas Burners
Open the catalog to page 1PREMIX GAS BURNERS One stage / Modulation PREMIX BURNERS InfraMix SERIES Dimensions (mm) *** L1, L2, L3, W1, W2 dimensions and mounting flange can be produced by customer specifications. *** Combustion heads is made by 4mm stainless steel material .
Open the catalog to page 2One stage / Modulation PREMIX BURNERS InfraMix SERIES Technical data Flame Controller Mounting Flange Reset / Alarm * Nominal Working pressure for LPG (propane) is 31 mbar. * Nominal Working pressure for Natural Gas (Methane) is 21 mbar. * Burners can be operate One Stage ( ON/OFF ) or Modulated ( 0-10 V / 4-20 mA ) . * Air filters (optional) usage strongly recommended in order to avoid dust in environment. * Flame controller (digital/manual), ON/OFF switch, temperature controller can be add as optional accesori
Open the catalog to page 3One stage / Modulation PREMIX BURNERS InfraMix SERIES Burner Accesories In order to connect burner with PLC system / Control panels the operation check, parameter 16 Pin Plug is available for easy modification and detailed information, connection, comissioning and maintenance. Burner Interface Modul It is possible to connect the Ignition controller to a Digital Burner Interface that allows remote control. On/OFF - Stand-by mode that allows flame control. In order to avoid from the pollution In order to use the burner with lasting use, CombHEX recommends special LPG kit is available with in...