Catalog excerpts

Quick Reference Cartridge Valves Technical Information Pilot operated check valves Quick reference Description Flow* Pilot Operated Check Valve, 12 l/min Pilot to Open [3 US gal/min] 25 l/min [7 US gal/min] 30 l/min [8 US gal/min] 70 l/min [18 US gal/min] Description Flow* Pilot Operated Check Valve, 20 l/min Reverse Pilot to Open [5 US gal/min] SDC10-3S 45 l/min [12 US gal/min] CP12-3S 95 l/min [25 US gal/min] SDC16-3S 130 l/min [34 US gal/min] CP20-3S 230 l/min [61 US gal/min] Pilot to Open Drain Description Flow* Pilot Operated Check Valve, 30 l/min Pilot-to-open with drain [8 US gal/min] * Flow ratings are based on a pressure drop of 7 bar [100 psi] unless otherwise noted. They are for comparison purposes only. 520L0588 • Rev DB • November 2010 Quick reference Pilot operated check valves
Open the catalog to page 1
Quick Reference Cartridge Valves Technical Information Pilot operated check valves Quick reference Symbol Description Flow* Pressure Pilot Operated Check Valve, 250 l/min 350 bar Reverse Pilot-to-open with [66 US gal/min] [5000 psi] vent Description Flow* Pressure Pilot Operated Check Valve, 45 l/min 210 bar Pilot to Close [12 US gal/min] [3000 psi] Cavity none 115 l/min [30 US gal/min] 190 l/min [50 US gal/min] Description Flow* Pressure Pilot Operated Check Valve, 85 l/min 210 bar Catalog HIC [22 US gal/min] [3000 psi] Quick reference Pilot operated check valves Dual Pilot-Operated Checks...
Open the catalog to page 2
Quick Reference Cartridge Valves Technical Information Pilot operated check valves Application notes Motion control valves, also referred to as load holding valves, are used to control the motion of a load in the following ways: · Prevent a load from dropping in case of hose or tube failure. Prevent a load from drifting caused by directional control valve spool leakage. Provide smooth, modulated motion when the load is in a lowering or run-away mode. Provide smooth, modulated motion when the directional control valve is suddenly closed. There are two basic types of motion control valves:...
Open the catalog to page 3
Quick Reference Cartridge Valves Technical Information Pilot operated check valves Application notes PILOT-OPERATED CHECK VALVES Pilot-operated, or pilot-to-open check valves will positively hold a pressurized load and will release the load upon application of a pressure signal to the pilot port. Pilot-operated check valves are available as individual cartridges, standard Cartridge-In-Body (CIB) packages, or can be created in custom manifolds by using a standard check valve such as CV10-NP with a guided pilot piston. For more information on pilot pistons, see Accessories. Individual...
Open the catalog to page 4
Quick Reference Cartridge Valves Technical Information Pilot operated check valves Application notes The pressure required to pilot open the check valve can be calculated by: P = W + (Pc • Ab) cylinder retracts (Ab • R) - Ar P = W + (Pc • Ar) cylinder extends (Ar • R) - Ab W = Load Pc = Check valve crack pressure (typically 0.34-4.5 bar [5-65 psi]; consult catalog sheets for details) Ab = Cylinder bore area Ar = Cylinder rod area R = Check valve pilot ratio (typically 3:1 or 4:1; consult catalog sheets for details) Note that these equations are idealized and do not consider any backpressure...
Open the catalog to page 5
Quick Reference Cartridge Valves Technical Information Pilot operated check valves Pilot to Open RPC 04 OPERATION This is a pilot-to-open check valve. pressure drop 26 cSt [125 SUS] hyd.oil @ 20° C [68° F] Rated pressure 210 bar [3000 psi] Rated flow at 7 bar 12 l/min [3 US gal/min] [100 psi] Weight 0.06 kg [0.13 lb] Pilot ratio 3.2:1 Cavity NCS04/3 Note: A piston seal requires a 4.5 bar [65 psi] or greater return spring. Pilot operated check valves Cross-sectional view ORDERING INFORMATION RPC 04 - 2.5 - OR - 00 - V Pressure to open 0.5 = 0.5 bar [7 psi] 2.5 = 2.5 bar [36 psi] 5.0 = 5 bar...
Open the catalog to page 6
Quick Reference Cartridge Valves Technical Information Pilot operated check valves Pilot to Open RPC 06 OPERATION This is a pilot-to-open check valve. Theoretical performance Rated pressure 315 bar [4500 psi] Rated flow at 7 bar 25 l/min [7 US gal/min] [100 psi] Weight 0.10 kg [0.22 lb] Pilot ratio 3.4:1 Cavity NCS06/3 Note: A piston seal requires a 4.5 bar [65 psi] or greater return spring. Pilot operated check valves Cross-sectional view ORDERING INFORMATION RPC 06 - 5 - OR - 00 - V Pressure to open 0.5 = 0.5 bar [7 psi] 5 = 5 bar [73 psi] Piston seals OR = Seals Omit = No seals Seals V =...
Open the catalog to page 7
Quick Reference Cartridge Valves Technical Information Pilot operated check valves Pilot to Open CP450-1 OPERATION This valve is a pilot-to-open check valve. Theoretical performance Rated pressure 240 bar [3480 psi] Rated flow at 7 bar 30 l/min [8 US gal/min] [100 psi] Leakage 6 drops/min @ Rated pressure Weight 0.09 kg [0.20 lb] Pilot ratio 3.0:1 Cavity SDC10-3 Note: A piston seal requires a 4.5 bar [65 psi] or greater return spring. Pressure drop free flow pilot open Pilot operated check valves Cross-sectional view ORDERING INFORMATION CP450 - 1 - B - 8S - 015 - 0 Seals B = Buna-N V =...
Open the catalog to page 8
Quick Reference Cartridge Valves Technical Information Pilot operated check valves Pilot to Open RPC 12 OPERATION This is a pilot-to-open check valve. Rated pressure 315 bar [4500 psi] Rated flow at 7 bar 70 l/min [18 US gal/min] [100 psi] Weight 0.20 kg [0.44 lb] Pilot ratio 2.8:1 Cavity NCS12/3 Note: A piston seal requires a 4.5 bar [65 psi] or greater return spring. Pilot operated check valves Cross-sectional view ORDERING INFORMATION RPC 12 - 5 - OR - 00 - V Pressure to open 0.5 = 0.5 bar [7 psi] 5 = 5 bar [73 psi] Piston seals OR = Seals Omit = No seals Seals V = Viton Omit = Buna-N...
Open the catalog to page 9
Quick Reference Cartridge Valves Technical Information Pilot operated check valves Pilot to Open CP458-2 OPERATION This valve is a pilot-to-open check valve. Theoretical performance Rated pressure 210 bar [3000 psi] Rated flow at 7 bar 20 l/min [5 US gal/min] [100 psi] Leakage 6 drops/min @ Rated pressure Weight 0.07 kg [0.15 lb] Pilot ratio 2.8:1 Cavity SDC08-3 Note: A piston seal requires a 4.5 bar [65 psi] or greater return spring. Pressure drop pilot open Pilot operated check valves Cross-sectional view ORDERING INFORMATION CP458 - 2 - B - 6S - 065 - 0 Seals B = Buna-N V = Viton Housing...
Open the catalog to page 10All Comatrol catalogs and technical brochures
-
brochure
24 Pages
-
check valve
36 Pages
-
Comatrol
24 Pages
-
Cross Reference
66 Pages
-
Cavities
46 Pages
-
D03 Directional Control Valves
12 Pages
-
Solenoid Valves
181 Pages
-
Counterbalance Valves
45 Pages
-
02 - CV - Check Valves
40 Pages
-
03 - SH - Shuttle Valves
14 Pages
-
04 - RV - Relief Valves
32 Pages
-
07 - FO - Flow Control Valves
54 Pages
-
06 - SQ - Sequence Valves
26 Pages
-
11 - LE- Logic Elements
84 Pages
-
13 - PV - Proportional Valves
64 Pages
-
14 - FD - Fan Drive HICs
14 Pages
-
15 - MM - Motor Mount HICs
106 Pages
-
17 - SP - Spreader Valve
8 Pages
-
21 - AC - Accessories
21 Pages
-
23 - HS - Housings
138 Pages
-
24 - CL - Coils
40 Pages
-
section7
50 Pages
-
section 11
52 Pages
-
section9
16 Pages
-
section 12
36 Pages
-
section 16
12 Pages
-
directional control valve
12 Pages
-
shuttle valve
12 Pages
-
section relief valve
30 Pages
-
reducing valve
12 Pages
-
sequence valve
26 Pages