Overview:
The VFM60 Vortex Flow Meter by Comate is engineered to measure the flow rate of gases, steam, and liquids using the Karman vortex theory. It includes advanced signal processing, a dual-sensor design for improved anti-vibration, and an open platform for customization.
Key Features:
  • Maintenance-free sensor design.
  • Self-diagnosis for troubleshooting.
  • Optional self-density calculation for mass flow rate without a mass flow computer.
  • Multi-variable version with built-in RTD and pressure sensor.
  • Bluetooth functionality for data access via the COMATE APP.
  • Password protection for device management.
Specifications:
  • Process Fluids: Suitable for homogeneous and single-phase liquids, gases, and steam.
  • Line Sizes: Wafer and flanged types cover sizes from 1” to 12” (DN25 to DN300), insertion type covers DN200 to DN1000.
  • Process Connection: Options include flange, wafer, and insertion with various standards (DN, ANSI, JIS, DIN).
  • Display: Integral or remote with a 2-line LCD display for various parameters.
  • Measurable Parameters: Volume flow rate, velocity, mass flow rate, temperature, and pressure.
Performance:
  • Repeatability: Volume flow ±1% for Re ≥ 20000, ±2% for 10000 < Re < 20000.
  • Turndown Ratios: Gas 1:30, Steam 1:35, Liquid 1:10.
  • Viscosity Allowance: Varies by DN size.
Measurement Range:
  • Gas: Min 6m/s for DN15, Max 60m/s for DN300.
  • Steam: Min 6m/s for DN15, Max 180m/s for external DN300.
  • Liquid: Min 0.3m/s, Max 7m/s.
Output and Communication:
  • Output Signal: Pulse, 4~20mA, ModBus-RTU RS485.
  • Pressure Allowance: Options up to 6.3MPa.
  • Communication: HART, Modbus-RTU, Pulse.
Additional Features:
  • Bluetooth function for data access within 5 meters.
  • Comprehensive measuring range tables for gas, steam, and liquid.
  • Pressure drop calculation formulas and factors provided.
Ordering Information:
The document provides detailed ordering information for the Comate Intelligent Sensor Vortex Flow Meter. The model number is structured as VFM-1-23456789-XXX, where each segment represents specific features and options.
Model Codes:
  • General Model: VFM60-N (Standard Vortex flowmeter without integral RTD and pressure sensor) or VFM60-M (Vortex mass flowmeter with integral RTD and pressure sensor).
  • Transmitter Location: T (Integral, standard 5m cable) or R (Remote).
  • Process Connection: 0 (Insertion for DN200~1000), 1 (Flanged), 2 (Wafer), 3 (Downsized wafer).
  • Fluid Type: 1 (Liquid), 2 (Gas), 3 (Steam).
  • Wetted Part Material: 1 (OCr18Ni9(304)), 2 (316), Q (Other).
  • Pressure Rating: 3 (1.6 Mpa), 4 (2.5 Mpa), 5 (4 Mpa), 6 (6.3 Mpa).
  • Medium Temperature: N (T≤150℃), S (T≤250℃), H (T≤350℃).
  • Transmitter: Options include pulse/4~20mA, pulse/HART@4~20mA, Pulse/RS485, and multi-variable versions.
  • Bluetooth: Q (No Bluetooth), B (With Bluetooth, requires RS485).
  • Cable Grinder: N (M20x1.5), Q (Other).
Pipe Size:
The three-digit code indicates the inner diameter of the pipe, e.g., 050 means DN50.
Example of Model Selection:
For an application involving saturated steam with a process pressure of 0.8Mpa and a flow rate of 800~4000kg/hr, using a DN100 (4”) ANSI flanged process connection with RS485+PULSE output and 24VDC power, the model number could be VFM60-N-T1313S9N100 or VFM60-M-T1313S7N100.
Counter Ordering Information:
At 0.8Mpa, the density of saturated steam is approximately 4.162kg/hr at 170 degrees C. The velocity range of 2~70 m/s is within the standard measurement range.
Counter Solution:
The model number for this solution is VFM60-N-T1313S9N100 or VFM60-M-T1313S7N100, suitable for ANSI flange, 0.8Mpa saturated steam, with temperature compensation and RTD required or choosing a multi-variable version.
See more

Catalog excerpts

VFM60 Vortex Flow Meter-1

Comate Intelligent Sensor Vortex flow meter datasheet VFM60 Vortex Flow Meter VFM60 is a powerful flow meter utilizing “Karman vortex” theory, which can meet the requirement of measuring the flow rate of various fluids such as gas, steam and liquid. The product uses the VFM60 transmitter technology, which provides with the excellent signal processing capability and enhance the vortex metering technology to a new level, which means it has lower measuring limit, better stability and accuracy. The unique dual-sensor design and special signal processing method has also ensured a better anti-vibration by eliminating the vibration signals to provide more reliable performance and lower measurement limit. The VFM60 platform is also an open platform, which means we can keep on upgrading its function according to customer’s unique requirement, and make the product a highly custom-orientation product. ⚫ ⚫ ⚫ ⚫ Sensor design that free from maintenance. Self-diagnose function, ensure easier trouble-shooting. Unique dual sensor technology excellent in anti-vibration. Self density calculation function is optional, can calculate density and mass flow rate without mass flow computer. Can output mass flow rate, temperature and pressure by working with separate RTD and pressure transmitter. Muti-variable version with built-in RTD and pressure sensor to measure standard/mass flow directly and display flow rate, temperature, pressure, mass flow rate and density as requires. Unit selectable function, meet different requirement from different area. Blue tooth function optional, can read flow rate and other data on COMATE APP with and smart phone or pad. Password can be set to protect setting model, easier for device management. Email: info@

 Open the catalog to page 1
VFM60 Vortex Flow Meter-2

Comate Intelligent Sensor Vortex flow meter datasheet - VFM60N Standard type digital vortex meter (without temperature&pressure compensation) - VFM60MV Multi-variable Vortex Meter (standard type support T≤ 150°) - VFM60MV Multi-variable Vortex Meter (high temperature version support 250°C<T≤350°C) Email: info@comateflowmet

 Open the catalog to page 2
VFM60 Vortex Flow Meter-3

Comate Intelligent Sensor Vortex flow meter datasheet 2. Specification 1) Process Fluids: Used in liquid, gas, and steam applications. Fluids must be homogeneous and single-phase. 2) Line Sizes: The wafer and flanged type cover line sizes as below. 1”, 1.5”, 2”, 2.5”,3”, 4”, 5”, 6”, 8”,10” ,12”, (DN25, DN40, DN50, DN65, DN80, DN100, DN125, DN150, DN200, DN250, DN300) The insertion type covers DN200~1000. Any requirement on other size, please check with our sales or engineers 3) Process connection: Flange, wafer, insertion.DN, ANSI, JIS, DIN Standard flanges are optional 4) Displayer: Integral...

 Open the catalog to page 3
VFM60 Vortex Flow Meter-4

Comate Intelligent Sensor Vortex flow meter datasheet Display 5) Measureable parameter Standard version: Volume flow rate in pipe, velocity (Can measure mass flow rate, temperature and pressure if wired to separate RTD and pressure transmitter.) Muti-variable version: Mass flow rate, volume flow rate in standard condition, temperature, pressure, volume flow rate in pipe, velocity. Product description Wafertype - Remote mount - Remote mount Flange type Flange Wafer Email: [email protected]

 Open the catalog to page 4
VFM60 Vortex Flow Meter-5

Comate Intelligent Sensor Vortex flow meter datasheet Sensor Anti-vibration vortex sensor Medium High Power supply External FRAM Saturated /superheated steam measurement Explosive proof Explosive proof Specification Flow rate (m3/h) Mass flow (kg/h) Gas/steam Liquid Steam turndown ratio Liquid turndown ratio Upstream/Downstream requires Viscosity allowance

 Open the catalog to page 5
VFM60 Vortex Flow Meter-6

Comate Intelligent Sensor Vortex flow meter datasheet Mass flow - Measurement range Medium - Output signal Pulse, high level ≥ 5V, 4~20mA(HART@4~20mA) ModBus-RTU RS485 - Pressure allowance 1.6MPa、2.5MPa、4.0MPafor option, VFM60N support up to 6.3Mpa. - Anti-vibration Medium Vibration type Vibration direction Circle time Circle time Remark 1) gas/steam reference to conditions under (T=25℃, P=101.325Kpa) tests; liquid 2) tests reference to

 Open the catalog to page 6
VFM60 Vortex Flow Meter-7

Comate Intelligent Sensor Vortex flow meter datasheet COMATE APP Blue tooth function is optional to all COMATE products. Customers can read all data of the meter in COMATE APP on an cellphone or pad. The signal is valid within about 5 meters in front of the meter. Gas/Steam measuring range Size mm Table 1 gas measuring range Range m3/h Output Hz range Email: [email protected]

 Open the catalog to page 7
VFM60 Vortex Flow Meter-8

Comate Intelligent Sensor Vortex flow meter datasheet 125 Table reference to conditions: ((T=25℃,P=0.1MPa,  =1.205kg / m , v = 15 10 m / s ) 3 Table 2 saturated steam measuring range——standard Standard Pressure Standard Pressure Email: info@comate

 Open the catalog to page 8
VFM60 Vortex Flow Meter-9

Comate Intelligent Sensor Vortex flow meter datasheet 4 Table 3 saturated steam measuring range——external External Email: info@comateflowmete

 Open the catalog to page 9
VFM60 Vortex Flow Meter-10

Comate Intelligent Sensor Vortex flow meter datasheet - Gas/steam pressure drop calculation Gas/steam pressure drop calculation formula: P=

 Open the catalog to page 10
VFM60 Vortex Flow Meter-11

Comate Intelligent Sensor Vortex flow meter datasheet 3 Liquid measuring range Size mm Table 2 Liquid measuring range Range m3/h Output Hz range

 Open the catalog to page 11
VFM60 Vortex Flow Meter-12

Comate Intelligent Sensor Vortex flow meter datasheet - Liquid pressure drop calculation C  Liquid drop calculation formula: P= 100 P:Kpa Picture 3, flow m3/hr, Liquid DN15~DN150 pressure drop factor

 Open the catalog to page 12
VFM60 Vortex Flow Meter-13

Comate Intelligent Sensor Vortex flow meter datasheet 1 流 量 m3/h Picture 4, flow m3/hr, Liquid DN200~DN300 pressure drop factor Dimension 1) Size and dimension for wafer type Wafer(in 250° C) Email: info@coma

 Open the catalog to page 13
VFM60 Vortex Flow Meter-14

Comate Intelligent Sensor Vortex flow meter datasheet Size screw hole Remark: The flange O/D, screw holes distance, flange thickness, screw holes diameter and screw qty are for the counter flanges, unit in mm. Counter flanges, screw and bolts, gaskets are usually along with package except customer do not need them. 2)Size and dimension for flanged type Email: [email protected]

 Open the catalog to page 14
VFM60 Vortex Flow Meter-15

Comate Intelligent Sensor Vortex flow meter datasheet O/D K screw hole Remark 1:L tolerance scope± 3mm ANSI/ASME-CLASS300 Size Flange screw hole distance Remark 1:L tolerance scope± 3mm DIN PN16 Size Pipe length Flange screw hole distance Email: info@comatefl

 Open the catalog to page 15

All COMATE catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.