Banks RC - 19" type
2Pages

{{requestButtons}}

Catalog excerpts

Banks RC - 19" type - 1

Banks RC-19’’ type - Platines série RC-19’’ RC rack modules represent the ideal solution for automatic P.F.C. equipment. Their rack mounting construction allows them to be installed easily and safely into any existing or new cubicle Les platines RC 19” représent la solution idéale pour une installation en armoires automatiques de compensation. MANUFACTURING CHARACTERISTICS CARACTERISTIQUES GENERALES Each unit, which can slide on bar guides, consist of: Frame: manufactured from zinc plated steel, including bar guides. Chaque tiroir est composé de: Chassis: en tôle zinguée glissant sur rails. Ventilation: natural. When designing P.F.C. equipment, always ensure adequate ventilation in order to operate at the lowest possible temperature. Cables: internal connecting cables are fire-proof, N07VK CEI 20-22 II type. Three-pole contactors: for high reliability each bank of capacitors is controlled by its own three-pole contactor, a control voltage of 240Vac 50HZ (other voltages on request). To limit the inrush current at switch on, each contactor is provided with insertion chokes or resistors. Fuses: every rack is protected by a set of three HRC fuses (NH00 type - curve gG) with high breaking capacity (100kA). Ventilation: naturelle. Prévoir toujours une bonne ventilation des condensateurs avec la possibilité de les faire travailler à une température la plus basse possible. Cables: type N07VK CEI 20-22 II Capacitors: self-healing polypropylene metallized single-phase (MKP), equipped with overpressure safety device and discharge resistor. All are compliant with IMQ standard and PCB free. Internal connection: delta. Max harmonic distortion of voltage allowed on capacitors is THDV=5%. Contacteurs tripolaires: chaque batterie est commandée par son propre contacteur de taille appropriée. La limitation de surcourant d’insertion est obtenu par inductances de choc ou résistances de précharge. Alimentation 240Vac 50Hz (autres tensions sur demande). Fusibles: chaque batterie est protégée par trois fusibles (NH00 série - courbe gG) avec haut pouvoir de coupure (100kA). Condensateurs: monophasée de type autocicatrisant, réalisés en film de polypropylène métallisé, ils sont équipés d’un système anti-éclatement de surpression et de résistance de décharge (approuvés IMQ). Ils ne contiennent pas de PCB. Connexion de condensateurs: triangle. Distortion harmonique max. de tension sur le condensateur THDV=5%. Voltage of the auxiliary circuits: 230Vac (110Vac on request) by installer. Rack manufactured: from 2 mm. zinc plated steel sheet Tension des circuits auxiliaires: 230Vac (110Vac sur demande) par installateur. Tôle: épaisseur 2 mm. MAIN FEATURES DONNES TECHNIQUES Dielectric: metallized polypropylene (MKP) Execution: oil (P.C.B. free) Capacitance tolerance: -5% / +10% Supply: three-phase + earth Rated frequency: 50Hz - 60Hz Max. allowable voltage: 1,1 Un (max 8h on 24h) Temperature class category: -25 °C / C max. value of ambient temperature: +50°C average daily ambient temperature: +40°C average yearly ambient temperature: +30°C Degree of protection (CEI EN 60529): IP 00 Frame: in zinc plated steel, including bar guides Reference Standards capacitors: CEI EN 60831-1/2, IEC 831-1/2 Max. permitted operating voltage (without harmonic distortion): 440Vac R15 - 550Vac B/3 - 600Vac B/5 Dielectric losses: ≤ 0,2 W/kvar Total losses of the capacitors: ≤ 0,4 W/kvar. Discharge resistor: 50Vresidual within 3min - included Limiting the inrush current: insertion resistor Capacitors unit mounting: vertical only Ventilation: natural Supply entry: on the fuse holders Type of service: continuous - indoors Diélectrique: polypropylène métallisé (MKP) Réalisation: huile (sans PCB) Tolérance sur la capacité: -5% / +10% Alimentation: triphasé + terre Fréquence nominale: 50Hz - 60Hz Max. valeur de tension: 1,1 Un (max 8 heures sur 24) Classe de température: -25 °C / C valeur max. de la température ambiante: +50°C moyenne journalière: +40°C moyenne annuelle: +30°C Degré de protection (CEI EN 60.529): IP 30 Chassis: en tôle zinguée, inclus rails Normes des références: CEI EN 60831-1/2, IEC 831-1/2 Tension de service permanent (sans charges harmonique): 440Vac R15 - 550Vac B/3 - 600Vac B/5 - 550Vac AAR/500 Pertes du diélectrique: ≤ 0,2 W/kvar Pertes max. par dissipation: ≤ 0,4 W/kvar. Résistances de décharge: 50V en 3min - incluses Limitation de courant d’insertion: résistance de précharge Montage de condensateurs: vertical Ventilation: naturelle Entrée des câbles: par le haut ou par le côte. Type de service: continu pour intérieur

Open the catalog to page 1
Banks RC - 19" type - 2

Banks RC-19’’ type - Platines série RC-19’’ ELECTRICAL CHARACTERISTICS CARACTERISTIQUES ELECTRIQUES RC racks are available in three versions for applications with different level of harmonic distortion of current allowed on capacitors (THDI): Les platines RC, sont disponibles en trois modèles pour des applications en réseaux avec différent % harmonique de courant sur les condensateurs (THDI): Type RC - R15 for max THDI 10% Type RC - B3 for max THDI 25% Type RC - B5 for max THDI 40% Série RC - R15 avec THDI max. 10% Série RC - B3 avec THDI max. 25% Série RC - B5 avec THDI max. 40% Type RC...

Open the catalog to page 2

All COMAR CONDENSATORI catalogs and technical brochures

  1. CS type

    3 Pages

  2. MC type

    2 Pages

  3. CT type

    2 Pages

  4. CTB series

    2 Pages

Archived catalogs

  1. QSR6 regulator

    22 Pages