Datasheet Order code: INEO6000BBB Controller for parallel hybrid applications Product description > InteliNeo 6000 is a controller for managing and optimizing on-grid and off-grid hybrid microgrid systems. The controller features real-time monitoring capabilities to balance power supply and demand and make real-time decisions for optimal energy management. > Single controller for renewables power sources and battery energy storage system y Native microgrid applications for on & off-grid systems with renewable energy and storage y Onboard Modbus Master for RTU/TCP support of up to 32 devices with extended device support via InteliGateway 300 y Hot-Swap* controller for system resilience and reduced downtime in case of fault (in primary controller) y Controller data encryption to protect prevent unauthorised views of controller configuration *Features available with software key y Supports black start of grid-forming battery storage systems y New CAN FD enabling cooperation with up to 64 additional gen-sets/mains/tie controllers y Import/Export to utility mains by load sharing or curtailment of renewables and storage y Compatible load/VAr sharing and power management with other ComAp solutions y Balance mode optimises use of energy by prioritising renewables before gensets/mains y CAN bus redundancy ensuring that a redundant CAN line be created and take over in case of CAN failure* y Built-in PLC interpreter via ComAp'sfree PLC Editor with new logic blocks for microgrid applications y Keeping your business and data as safe as possible with controller designed to the ISA 62443 level 2 - level 3 security requirements y Controller data encryption and User-defined protections to protect prevent unauthorised views of PLC Editor and setpoints on top of default protection y AirGate 2.0 for easy connection to your equipment remotely without worrying about your asset’s IP address y Remote control and monitoring of your microgrid with WebSupervisor, our cloud-based fleet management tool Application overview | InteliNeo 6000 1.5.0 Datasheet | Related HWver: 1.0.0 | Related SWver: 1.5.0 | Date of issue: 8/6/2024
Open the catalog to page 1Terminals and dimensions Current E-Stop input Ethernet ports USB Device RS485
Open the catalog to page 2Power supply Power supply range Power consumption RTC battery Fusing power Consumption Fusing E-STOP Max. Heat Dissipation Operating conditions Operating temperature Storage temperature Operating humidity (norm 60068-2-30) Protection degree Binary inputs Number Close/Open indication Configurable Pulse input Number Max. current Switching to 12, non-isolated 0-2 V DC close contact 6-36 V DC open contact Pull-up/Pull-down Bin 9 and 10 max. 50 Hz Positive supply terminal Surrounding air temperature rating 70 °C. Suitable for pollution degree 2. 4, switchable (R/U/I) R = 0-10000 D;U = 0-10V;I = 0-20...
Open the catalog to page 3Product Order code Available external displays Product InteliVision 5.2 InteliVision 10Touch InteliVision 13Touch InteliVision 18 5" TFT external display with 800x480 px resolution 10.1" Touchscreen display uni with 1280 x 800 px resolution 13.3" Marine certified display unit with 1920 * 1080 px resolution 18.5" Touchscreen display unit with 1366 * 768 px resolution Available CAN modules Product Inteli AIN8 Inteli AIN8TC 8 Analog Input Channels and 1 RPM/Impulse Input Module 8 Analog Input Channels for termocouples measurement 4 Analog Inputs for differential voltage measurement, 4 Analog Input...
Open the catalog to page 4Annunciator Overload Load shedding * extension module IGL-RA15 required Description Overcurrent IDMT Earth fault current IDMT AC circuit breaker Description Regulating device * ULC 6200:2019Certified (see the NFL File forthe FWversion with the Witnesstest if it is required by the certification of the end product) Grid codes European Requirements for Generators, 2016/631 y American IEEE 1547 > UK ENA EREC G99 SW Key Feature CAN bus redundancy Hot Swap Redundancy Order Code E-mail: [email protected] Web: www.comap-control.com CornApj^ The heart of smart control ©ComAp. Featuresand specification...
Open the catalog to page 54 Pages
5 Pages
3 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
5 Pages
6 Pages
4 Pages
4 Pages
5 Pages
7 Pages
4 Pages
2 Pages
4 Pages
5 Pages