IL3LAMF9BAA-1

Datasheet Order code: IL3LAMF9BAA Controller for single gen-set applications Product description ► Single gen-set controller for stand-by and prime-power applications ► Direct communication with EFI engines ► All-in-one intuitive & powerful PC tool for configuration/monitoring/control, locally or remotely ► Stand-by and prime-power application in one unit ► 5 languages in the controller & Translator functionality ► 3 sets of alternative configurations ► ECU support & Tier 4 Final ready ► Plug-in module concept for more capabilities (Modbus, Internet, SMS, inputs/outputs) ► 1 slot for plug-in modules ► Power over USB for controller’s adjustment ► Fuel Pump control ► 6 binary outputs, 6 + 1 binary inputs, 3 analog inputs ► 2 high-current binary outputs ► Adjustable delay for binary inputs ► Alarms and gen-set status assignable to binary outputs ► Run Hours source selector ► Multi-purpose scheduler functionality ► Detailed history log with up to 150 records ► Zero power mode ► Possibility to disable protections ► Modbus register mapping possibility ► Start on low battery (only for native prime-power configuration) ► Cutout: 172 mm x 112 mm (same as IL-NT family) Application overview Mains & Generator Circuit Breaker Generator Circuit Breaker | Related HWver: 1.0.0 | Related SWver: 1.0.0

 Open the catalog to page 1
IL3LAMF9BAA-2

Dimensions, terminals and mounting Note: The final depth of the controller depends on the selected extension module - it can vary between 41 mm and 56 mm. Mind also the size of connectors and cables (e.g. in case of RS232 connector, add about 60 mm more for a standard RS232 connector and cable). Note: Enclosure type rating with mounting instruction - for use on a flat surface of a type 1 enclosure.

 Open the catalog to page 2
IL3LAMF9BAA-3

Technical data Power supply Power supply range Power consumption E-Stop Dedicated terminal for safe Emergency Stop input. Physically disconnects BO 1 & BO 2 from power supply. Fusing E-Stop Max. Power Dissipation Binary inputs Number Close/Open indication 6, non-isolated 0-2 V DC close contact >6 V DC open contact Binary outputs Max. output current Charging fail threshold max 0.5 A switching to positive supply voltage, BATT+ Operating conditions Operating temperature High current °C) switching to positive supply Storage temperature Protection degree (front panel) Operating humidity voltage, E-Stop...

 Open the catalog to page 3
IL3LAMF9BAA-4

Available extension modules Description ForSMS and GPS info Ethernet interface ForSMS Dual port interface 8 additional binary inputs/outputs Note: This controller has 1 slot for plug-in modules. Description ANSI code ** Phase rotation only, fixed setting Description ANSI code Voltage asymmetry and Phase rotation** 47 Over frequency 81H c(V^us LISTED The heart of smart control * ^ Czech Republic E-mail: [email protected] Phone: +420 246 012111 Web: www.comap-control.com © ComAp. Features and specification are subject to change without prior notice.

 Open the catalog to page 4

All ComAp catalogs and technical brochures

  1. RD21050MBGA

    4  Pages

  2. IG4500XXBAA

    5  Pages

  3. CM223248XBX

    3  Pages

  4. IG4500XXBAA

    5  Pages

  5. ID2IPUXXBAA

    4  Pages

  6. BC212V05BOB

    4  Pages

  7. RD2IV18TBPE

    4  Pages

  8. IS2GASXXBAB

    4  Pages

  9. CM2GW101BAB

    4  Pages

  10. I-AIO9/1

    4  Pages

  11. ID-DCU Marine

    2  Pages

  12. OT1A3GGPACX

    5  Pages

  13. INEO6000BBB

    6  Pages

  14. INEO6000BBB

    5  Pages

  15. IG-NTC-BB

    4  Pages

  16. IM31010SCBB

    5  Pages

  17. EM1DC44XBDB

    7  Pages

  18. IL4AMF20BAA

    4  Pages

  19. CM3ETHERXBX

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.