Datasheet Order code: IL3LAMF9BAA Controller for single gen-set applications Product description ► Single gen-set controller for stand-by and prime-power applications ► Direct communication with EFI engines ► All-in-one intuitive & powerful PC tool for configuration/monitoring/control, locally or remotely ► Stand-by and prime-power application in one unit ► 5 languages in the controller & Translator functionality ► 3 sets of alternative configurations ► ECU support & Tier 4 Final ready ► Plug-in module concept for more capabilities (Modbus, Internet, SMS, inputs/outputs) ► 1 slot for plug-in modules ► Power over USB for controller’s adjustment ► Fuel Pump control ► 6 binary outputs, 6 + 1 binary inputs, 3 analog inputs ► 2 high-current binary outputs ► Adjustable delay for binary inputs ► Alarms and gen-set status assignable to binary outputs ► Run Hours source selector ► Multi-purpose scheduler functionality ► Detailed history log with up to 150 records ► Zero power mode ► Possibility to disable protections ► Modbus register mapping possibility ► Start on low battery (only for native prime-power configuration) ► Cutout: 172 mm x 112 mm (same as IL-NT family) Application overview Mains & Generator Circuit Breaker Generator Circuit Breaker | Related HWver: 1.0.0 | Related SWver: 1.0.0
Open the catalog to page 1Dimensions, terminals and mounting Note: The final depth of the controller depends on the selected extension module - it can vary between 41 mm and 56 mm. Mind also the size of connectors and cables (e.g. in case of RS232 connector, add about 60 mm more for a standard RS232 connector and cable). Note: Enclosure type rating with mounting instruction - for use on a flat surface of a type 1 enclosure.
Open the catalog to page 2Technical data Power supply Power supply range Power consumption E-Stop Dedicated terminal for safe Emergency Stop input. Physically disconnects BO 1 & BO 2 from power supply. Fusing E-Stop Max. Power Dissipation Binary inputs Number Close/Open indication 6, non-isolated 0-2 V DC close contact >6 V DC open contact Binary outputs Max. output current Charging fail threshold max 0.5 A switching to positive supply voltage, BATT+ Operating conditions Operating temperature High current °C) switching to positive supply Storage temperature Protection degree (front panel) Operating humidity voltage, E-Stop...
Open the catalog to page 3Available extension modules Description ForSMS and GPS info Ethernet interface ForSMS Dual port interface 8 additional binary inputs/outputs Note: This controller has 1 slot for plug-in modules. Description ANSI code ** Phase rotation only, fixed setting Description ANSI code Voltage asymmetry and Phase rotation** 47 Over frequency 81H c(V^us LISTED The heart of smart control * ^ Czech Republic E-mail: [email protected] Phone: +420 246 012111 Web: www.comap-control.com © ComAp. Features and specification are subject to change without prior notice.
Open the catalog to page 44 Pages
5 Pages
3 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
5 Pages
6 Pages
5 Pages
4 Pages
4 Pages
5 Pages
7 Pages
4 Pages
2 Pages
4 Pages
5 Pages