Datasheet Product description ► Comprehensive paralleling gen-set controller ► Parallel operation up to 32 gen-sets ► High level control for complex systems ► Load sharing and VAr sharing via CAN ► Virtual shared inputs and outputs via CAN ► Support of wide range of applications ► Single or multiple gen-sets in parallel to mains operation with automatic back up function, multiple island operation ► Advanced power management function ► Customizable load control in parallel to mains ► Wide range of ECU support • Timers,Internal PLC , Force values and more ► Compatible with ComAp's InteliVision displays ► Active e-mail messaging and SMS with optional communication module ► Extensive built-in protection functions • Standard protections • User configurable protection Application overview ► Extendable with ComAp's extension modules ► True RMS (TRMS) is used with Voltage, Current and Power measurement | Related SWver: 3.3.0 | Date of i
Open the catalog to page 1Technical data Power supply Binary outputs Power supply range Power consumption RTC battery Fusing Positive supply terminal 10 years (replaceable by official service) 2 A (without BOUT consumption) Operating conditions Analog inputs 3 non-isolated Switchable (Voltage, Resistance, Operating temperature Storage temperature Current) 10 bits, max 4 decimals Input impedance ±1 % of meas. value ±1 mV ±2 % of meas value ±2 Ω Operating humidity Voltage measurement Measurement inputs 3 ph-n Gen voltage 3 ph-n Mains/Bus voltage Input impedance Accuracy Input impedance Frequency measurement tolerance Voltage...
Open the catalog to page 2Controller panel door mounting Note: InteliGen NT can be mounted into panel doors as a standalone unit using provided metal holders. The cut-out for the unit should be 1 mm wider then the unit on each side (i.e. cut-out dimensions 172 × 112 mm).
Open the catalog to page 3Available extension modules Product Order code Order code INTELIVISION 5 INTELIVISION 8 RD1IV12TBZH 8 Binary inputs, 8 Binary outputs and 2 Analog outputs packed in a small unit (HW switchable to IO16/0) 8 Analog inputs (R, I, V) and 1 pulse/frequency input in a small unit 8 Thermocouple Analog inputs in a small unit 9 Analog inputs (4x DC, 4x thermocouples, 1x R) in a small unit 8 Analog inputs packed in a rugged metal unit 8 Binary inputs, 8 Binary outputs, 4 Analog inputs and 1 Analog output in a unit 15 Binary LED output (3 colors) packed in a rugged metal unit 8 Analog outputs packed in...
Open the catalog to page 44 Pages
5 Pages
3 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
5 Pages
6 Pages
5 Pages
4 Pages
4 Pages
5 Pages
7 Pages
4 Pages
2 Pages
5 Pages