Overview: The industrial water softener is designed to maintain optimal performance levels in various systems by reducing calcium and magnesium content in water, which causes scaling. It is suitable for installations treating large volumes and flows, such as in hotels, industrial plants, schools, and medical facilities.
Operating Principle: The softener uses ion exchange resins to convert calcium and magnesium into sodium, resulting in 'soft' water that prevents scaling. The system requires periodic regeneration using a sodium chloride solution, which is automatically activated based on volume or time.
Installation and Maintenance: Installation support and initial startup are provided. Regular maintenance includes disinfecting resins annually and checking salt levels. The system comes with a one-year parts and labor guarantee, excluding consumables and transport.
Technical Characteristics: The softener features a Noryl or bronze head with electronic volume measurement, operates at 24 V 50 Hz, and supports service pressures from 2 to 8 bars and temperatures from 2 to 40 °C. It includes a salt box with a dual safety float and a remineralizing valve.
Sizing and Configuration: Proper sizing is crucial for effective operation, considering factors like water consumption, peak flow rates, water hardness, and system pressure. The document provides detailed specifications for simplex and duplex configurations, with capacities ranging from 3.2 to 21 m³/h.
Options: Additional features include upstream filtering, automatic chlorination, and low salt level detection.
See more

Catalog excerpts

Volumetric Duplex alternating water softeners with metal head-1

INDUSTRIAL WATER SOFTENER (from 3,2 to 21 m³/h) OPERATING PRINCIPLE Water softeners modify the physical and chemical composition of water, reducing both calcium and magnesium, which cause scaling. The water to be softened transits through ion exchanging resins (strong cationic resins), which change the calcium and/or magnesium into sodium. The water delivered by the softener no longer causes scaling, and has become ‘soft’. The purpose of the water softener is to provide maximum protection against scaling in pipes and other equipment. As the water passes through, the resins become saturated with calcium and magnesium. A regeneration cycle is then necessary, to recharge the resins in sodium ions, from a sodium chloride solution or brine (salt and water), which the softener takes from the salt box. Regeneration is activated automatically, during the night, by an automatic system integral with the softener head. Regeneration can be activated in 2 ways: - based on volumes consumed (volume mode), - based on time interval (time mode). Cycles start at 2 am (time can be set as required) Normal cycle sequence during the day. FIELDS OF APPLICATION Industrial softeners are designed for any installation treating large volumes and flows. They can be installed on systems with one or more water points. The most frequent installations are in: hotels, industrial plants (process/general system), schools, etc, community buildings, medical sector (hospitals, clinic, retirement homes). Softeners are installed on pipes carrying cold water that is to be heated to provide sanitary hot water, in all public or community buildings (public health laws). MAJOR ADVANTAGES of the softener - softener maintains protected systems at their nominal performance levels (boilers, panel exchangers, washing A tunnels, osmosis units, kitchens (oven and dish washer), sterilising equipment and sanitary wear). - A softener is also recommended for optimum operation of Jacuzzis, Turkish baths and hydrotherapy. - The softener is adjusted electronically, to ensure optimum efficiency and minimum salt and water consumption.

 Open the catalog to page 1
Volumetric Duplex alternating water softeners with metal head-2

INDUSTRIAL WATER SOFTENER (from 3,2 to 21 m³/h) TECHNICAL CHARACTERISTICs Installation / Maintenance - Noryl or bronze head, electronic volume measurement. - Regeneration: 5 phases. - Electrical system: 24 V 50 Hz (transformer supplied). - Service pressure: 2 to 8 bars. - Service temperature: 2 to 40 °C. - Supplied with salt box floor and dual safety float. - upplied with remineralising (mixing) valve compatible with S the installation. - Food grade resin, approved by the Ministry of Health. - e help you install the equipment, and our technicians manage W the initial startup. - ervicing assistance...