Operating Principle
The Bio-rain system processes recovered water (rain, borehole, or well water) through a series of filtration and purification steps. Initially, water is filtered through a washable filter that removes particles larger than 90 µm. It then passes through a micro-porous active carbon filter, eliminating impurities over 10 µm and odors. Finally, UVC lamps perform antibacterial functions by destroying microorganisms and viruses without chemicals.

Regulatory Encouragement
The use of recovered rainwater is promoted by French legislation (Act of 21st August 2008) and European Directive 200/60/EC. This system is ideal for new constructions, requiring a dual water system or a disconnection system.

Applications
Recovered water can be used for non-potable purposes such as toilets, washing machines, cleaning, swimming pools, and garden irrigation, leading to significant household water savings.

Maintenance
  • Regular cleaning of the UVC generator quartz tube is necessary.
  • UVC lamps should be replaced every 9000 hours.
  • The 90 µm filter cartridge should be washed every 3 months.
  • The 10 µm filter cartridge should be replaced every 3 months.
  • Avoid exposure to UVC lamp radiation.

Guarantee
The system comes with a three-year guarantee covering parts and labor, excluding consumables and transport.

Technical Characteristics
  • Connections: ¾" inlet and outlet.
  • Power supply: 230 V - 50 Hz with earth.
  • Fuse: F. 5x20 T 1 A.
  • UVC lamp power: 36 W.
  • Water temperature: 5 to 20 °C.
  • Ambient temperature: 5 to 35 °C.
  • Water pressure: 2 to 5 bars (pressure reducing valve needed if over 5 bars).
  • Max treatment rate: 2 m³/h.

Standard Installation
The Bio-rain kit can be installed in any standard rainwater recovery system, either upstream of a new secondary system or downstream of a compressor, as per the Act of 21st August 2008. Dimensions are L 540 mm x H 600 mm x D 280 mm, with 50 cm of unobstructed space required for lamp changes.

Installation
The kit is designed for easy installation in a frost-protected technical equipment room or garage.

Spare Parts
  • 36 W lamp: Part number 543092
  • 90 µm filter cartridge: Part number 527309
  • 10 µm filter cartridge: Part number 527809
  • Quartz sheath with seal: Part number 543099
  • Quartz seal: Part numbers RI500072, RI610087
  • Cleaner quartz: Part number Q516005001
See more

Catalog excerpts

kit bio-rain-1

TREATMENT OF RECOVERED WATER (RAIN, BOREHOLE OR WELL WATER) REFERENCE Q211 003 001 TREATMENT AND UTILISATION of recovered water Recovering rain water is being widely adopted. Especially as it is encouraged by the French authorities in the act of 21st august 2008, and also by Europe, through directive 200/60/EC. The installation of this type of system is perfect when building a new house, as the water system needs to be doubled, or a disconnection system is required, in accordance with the act of 21st august 2008. Recovered water can thus be used in the secondary system, resulting in significant savings on everyday household consumption: toilet, washing machine, housework, swimming pool, watering the garden, etc. OPERATING PRINCIPLE The water collected in your tank is transferred from the tank to your Bio-rain system. It is ltered a rst time by a washable lter. This lter traps all matter in suspension exceeding 90 µm. The water then passes through a micro-porous (active carbon) filter, which filters out all impurities bigger than 10 µm and gets rid of unpleasant smells through an absorption process. Thus micro-pollution particles exceeding 10 µm are trapped by this cartridge. Finally, the UVCs perform their antibacteria function. They continuously kill the NDA and NRA of the micro-organisms and viruses present in the water, without using chemical substances.

 Open the catalog to page 1
kit bio-rain-2

TREATMENT OF RECOVERED WATER (RAIN, BOREHOLE OR WELL WATER) REFERENCE Q211 003 001 TECHNICAL CHARACTERISTICS - ¾" inlet and outlet connections. - Clean the UVC generator quartz tube regularly – consult the servicing/maintenance manual. - Power supply required 230 V - 50 Hz + earth. - Fuse: F. 5x20 T 1 A. - UVC lamp power: 36 W. - Water temperature: 5 to 20 °C. - Ambient temperature: 5 to 35 °C. - Water pressure: 2 to 5 bars (max. - install a pressure reducing valve if water pressure exceeds 5 bars). - Max. treatment rate: 2 m³/h. - Preliminary lter: 90 µm. - Main lter: 10 µm. - Change the lamps...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.