Catalog excerpts
Pulse inputs for NPN, PNP or voltage signals Built-in supply for external sensor 16 metering ranges, switch selectable Galvanically isolation between supply, input and output Current, voltage or relay output DC supply or AC supply voltages up to 230 VAC Made in accordance with the and EMC regulations Hysteresis: Relay version: Metering ranges: Pulse/pause ratio: 5% 16 Selectable ranges from 0-100 p.p.m. to 0-20000 Hz. min 10% at max speed for each range (min 15µsec. at range D,E and F) Front view: The C-macâ converter, type LR10 is used for speed monitoring, where the input signal comes from a contact, a proximity sensor, a flow transducer or similar. The unit is supplied with a 24 VDC, max. 25 mA output, which can be used to supply an external proximity sensor. The unit is supplied with either analogue or relay output. By means of a rotary switch on front of the unit you can select between 16 different metering ranges from 0-100 p.p.m. to 0-20000 Hz. With analogue outputs you use another switch to select the output range (0-20 / 4-20 mA or 0-10 / 2-10 V) and to enable fine-adjustment of the metering range With the fine-adjustment you can select any range between the nominal range lower than the actual range up to maximum of the actual range. With relay output you use the switches to select the relay functions (relay on / relay off) The analogue output level is updated at each input pulse (at high speed ranges 10 times per second), which ensures a quick reaction and a stable output signal, even at very low input frequencies. Technical data: 24, 115 and 230 VAC +/- 10% 40-70 Hz 12-50 VDC Supply - internal electronics: 3.75 kV Input - output: 2.5 kV Power consumption: 3 VA Operation temp.: -20°C to +60°C Humidity: 0 - 90% RH, non condensing Temp. coefficient: < 0,01% /°C Transducer supply: 24 VDC, max. 25 mA Indications: Green LED: Supply ON 2 red LED’s: Relay 1 and 2 active (only modules with relay output) Accuracy: better than 0.3% Resolution: 0.1% Adjustments, analogue units: Span adjustment. relay units: setpoint adjustment relay 1 and 2. adjustment range 10 - 100% Supply voltage: Supply frequency: Supply voltage DC: Isolation voltages: SW 1: Range selection: 0 = 0 - 100 p.p.m. 8 = 0 - 100 Hz 1 = 0 - 200 p.p.m. 9 = 0 - 200 Hz 2 = 0 - 500 p.p.m. A = 0 - 500 Hz 3 = 0 - 1000 p.p.m. B = 0 - 1000 Hz 4 = 0 - 2000 p.p.m. C = 0 - 2000 Hz 5 = 0 - 5000 p.p.m. D = 0 - 5000 Hz 6 = 0 - 10000 p.p.m. E = 0 - 10000 Hz 7 = 0 - 20000 p.p.m. F = 0 - 20000 Hz SW 2.1, analogue version: Output offset off: 0-20 mA / 0-10 V on: 4-20 mA / 2-10 V SW 2.1, relay version: Inversion, relay 1 SW 2.2, analogue version: Range adjustment off: Factory adjusted on: manual adjustment SW 2.2, relay version: Inversion, relay 2 LED1: Power on LED2: Relay 1 on LED3: Relay 2 on P 1, analogue version: Manual range adjustment P 1, relay version: setpoint adjustment, relay 1 P 2, relay version only: setpoint adjustment, relay 2
Open the catalog to page 1Mechanical dimensions: Materials and weight: Housing base: Terminal cover: Terminals: Screws: Weight: Electrical connections: Block diagram, analogue outputs: P 1 Block diagram, relay outputs: PP 12 Supply voltage: Input circuit: Common DC supply out Voltage input: Input active: not active: NPN input: Input active: not active: PNP input: Input active: not active: Analogue output: Common: Current out: Voltage out: Relay output: Relay 1: Relay 2: Max load: pins 15 and 16 Pin 8 Pin 1, 24 VDC, max load 25 mA Pin 4, AC or DC signals, max 50 V input resistance 50 kOhm Vin > 3 V Vin < 1.5 V Pin 6,...
Open the catalog to page 2All COMADAN catalogs and technical brochures
-
60 point LED bargraph AP560
1 Pages
-
kW transmitter FPA96
1 Pages
-
Power guard RP91
4 Pages
-
Test instrument MS4201
1 Pages
-
RT18, Star-delta relay
1 Pages
-
RD20, amplifying relay
1 Pages
-
RR10, tachometer relay
2 Pages
-
RF20, frequency relay
2 Pages
-
RL10/RL11/RL12
2 Pages
-
RC15/RC20, current relays
2 Pages
-
RM34
2 Pages
-
MP92, torque monitor
2 Pages
-
RP33, 3-phase monitoring
1 Pages
-
RP32, phase sequence relay
1 Pages
-
RP10, 1-phase monitoring
1 Pages
-
Programmable converter PPV10
4 Pages
-
Programmable converter PMR10
4 Pages
-
Programmable converter PCV10
4 Pages
Archived catalogs
-
MS4201
1 Pages
-
Series CS/SC
2 Pages
-
RV20, voltage relay
2 Pages
-
RP91, power monitoring relay
4 Pages
-
Series FP, 3-phase relays
3 Pages
-
TT22
1 Pages
-
FPA90, Power converter
2 Pages
-
Temperature sensors
2 Pages
-
Automatic timers RT1X
2 Pages
-
Phase asymmetry relay RP31
1 Pages
-
Power supply series PSD
1 Pages