  3. RP81, 3-phase phase angle relay

RP81, 3-phase phase angle relay
1 /2Pages

RP81, 3-phase phase angle relay

RP81, 3-phase phase angle relay
1 /2Pages

Catalog excerpts

RP81, 3-phase phase angle relay-1

Load guard for 3-phase motors Power factor metering (cos j) Adjustable time delay 0-20 sek. at motor start Selectable release of relay at max. or min. load 1-pole relay output 8A / 250 VAC Produced in accordance with and EMC regulations C-mac® module type RP81 is used for load monitoring of 3-phase motors, as the phase angle (cos j) between motor current and -voltage changes in proportion to the mechanical load of the motor. You will see the biggest change in phase angle, if the motor is loaded between 0 and 60% of nominal load, which makes the RP81 suitable for monitoring of V-belts, pumps running dry, etc. (see page 6-6). RP81 can be connected directly to motors with nominal current up to 6 A. If the current is bigger, you use a standard current transformer. The unit is supplied with an adjustable start-up delay, which keeps the output relay activated independant of the power consumption, when the motor is starting. By connection of pins 7 and 2 you can select if the relay releases at over- or underload. Relay function: When the supply voltage is connected, the output relay activates, and the start-delay will start, independant of the selected relay function. pins 2-7. If pin 2 is not connected, the output relay releases immediatly, if the power factor exceeds the set level, provided that the set start-delay has run out. If pin 2 is connected to pin 7, the relay releases, if the power factor is lower than the set level, and the timer has run out. Functional diagram: supply Technical data: Supply voltage: Supply frequency: Power consumption: Operation temp.: Humidity: Monitoring current: Internal shunt: Hysteresis: Adjustments: Start delay: Level: Accuracy, scale: Start delay: Level: Indications: Green LED: Red LED: 3 x 230 V +/- 10% 3 x 400 V +/- 10% 3 x 415 V +/- 10% 40-70 Hz 2,5 VA -20°C to +60°C 0 - 90% RH, non-condensing min. 0,5 A, max. 6 A At bigger currents use a standard current transformer.. 33 mW. At max. current 6 A the voltage across the shunt is 0,2 V 5% of adjusted level. setpoint hysteresis load relay, ex. 1 relay, ex. 2 t = selected start-up delay ex. 1: overload, pins 2-7 open ex. 2: underload, pins 2-7 connected Potentiometer, 0-20 sec. Potentiometer, cos.j 0-0,9 20% 5% Supply voltage connected Relay activated

 Open the catalog to page 1
RP81, 3-phase phase angle relay-2

Ordering guide: without current transformer. (motor current smaller than 6 A) With current transformer. (motor current bigger than 6 A) Note: the current transformer must be connected as shown (P1 / P2 and S1 / S2) C-mac Control module 4 Supply Relay Materials and weight: Housing: NORYL-SE-1, grey, self-extinguishing Housing bottom: NORYL SE-1, GFN-2, black, self-extinguishing Terminals: Nickel-plated brass Weight: 110 g

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.