Temperature monitoring relay for Pt100 sensor 4 metering ranges in one module Adjustments for setpoint and time delay Selectable range, relay inversion and time delay Cable resistance compensation 1- or 2-pole relay output DC supply or AC supplies up to 230 VAC Made in accordance with the and EMC regulations C-mac® monitoring relay, type RM34, is used for temperature metering in conjunction with Pt100 temperature sensors according to DIN 43760. A 3-wire metering principle is used, which means that the module compensates for the external cable resistance. The cable monitoring circuit also ensures that the relay will release in case of short-circuit or cable breakage. By means of a DIP-switch in the bottom of the unit you can select between 4 metering ranges and 4 different combinations of relay inversion and reactiondelay. The 4 metering ranges are: -50 - 50 °C 0 - 100 °C 50 - 150 °C 100 - 200 °C With the relay inversion you can select, if the unit is used for heating or cooling. The time-delay is adjustable between 0 and 10 sec. The module is available with either 1- or 2-pole relay output. On the front of the unit you can adjust the setpoint and reaction-delay between 0 and 10 seconds. The unit is supplied for 24, 115 or 230 VAC supply or 10-50 VDC sypply. Functional diagram: setpoint hysteresis inp. signal output, ex.1 output, ex.2 output, ex.3 output, ex.4 t Function and range selection: SW 1 Relay activates, when setpoint is exceeded, delay on release Relay releases, when setpoint is exceeded, delay on activate Delay on activate, when setpoint is exceeded Delay on release, when setpoint is exceeded Metering range
Open the catalog to page 1Common technical data: Supply, AC: Supply frequency: Supply, DC: Isolation voltage: Power consumption: Operation temp.: Humidity: Temp. coefficient: Indications: Green LED, active: flashing: Connection diagram: C-mac Control module 4 Emmision: EN 50 081 - 1 Immunity: EN 50 082 - 2 Safety: EN 60 730 Approvals: The units are produced in accordance with the CE og low voltage regulations. Connection 8-9-11: 2-pole version only Supply ON and input OK Supply ON and input signal outside the metering range or cable fault Relay active Red LED: Selection of function: S1-S2: relay inversion and...
Open the catalog to page 2All COMADAN catalogs and technical brochures
-
60 point LED bargraph AP560
1 Pages
-
kW transmitter FPA96
1 Pages
-
Power guard RP91
4 Pages
-
Test instrument MS4201
1 Pages
-
RT18, Star-delta relay
1 Pages
-
RD20, amplifying relay
1 Pages
-
RR10, tachometer relay
2 Pages
-
RF20, frequency relay
2 Pages
-
RL10/RL11/RL12
2 Pages
-
RC15/RC20, current relays
2 Pages
-
MP92, torque monitor
2 Pages
-
RP33, 3-phase monitoring
1 Pages
-
RP32, phase sequence relay
1 Pages
-
RP10, 1-phase monitoring
1 Pages
-
Tachometer converter
2 Pages
-
Programmable converter PPV10
4 Pages
-
Programmable converter PMR10
4 Pages
-
Programmable converter PCV10
4 Pages
Archived catalogs
-
MS4201
1 Pages
-
Series CS/SC
2 Pages
-
RV20, voltage relay
2 Pages
-
RP91, power monitoring relay
4 Pages
-
Series FP, 3-phase relays
3 Pages
-
TT22
1 Pages
-
FPA90, Power converter
2 Pages
-
Temperature sensors
2 Pages
-
Automatic timers RT1X
2 Pages
-
Phase asymmetry relay RP31
1 Pages
-
Power supply series PSD
1 Pages