RC12: Current monitoring RV12: Voltage monitoring 3 metering inputs in each module Adjustments for setpoint and hysteresis Selectable relay inversion and AC/DC mode DC supply or AC supplies up to 230 VAC Made in accordance with the and EMC regulations C-mac® current monitoring relay, type RC12, and voltage monitoring relay, type RV12, are universal metering relays, each supplied with 3 metering ranges, from 4 mA to 6 A or 400 mV to 600 V AC or DC, respectively. The input range is chosen by use of the appropriate input terminal, and the choice of AC/DC metering and relay inversionis made by connection/disconnection of terminal 5 and 8 to common (terminal 7). When the module is AC metering, the average value is metered, and the level adjustment is then calibrated to the r.m.s. value of a sinusoidal signal. Metering ranges, max. input signals and input impedances (Rin): Module Power consumption: Operation temp.: Humidity: Adjustments: Level: Hysteresis: Indications: Green LED: Red LED: Accuracy, scale: Temp. coefficient: Max. load, relay: Common technical data: Supply voltage, AC: Supply frequency: Variable supply: Isolation voltage: Supply voltage, DC: 24, 115 and 230 VAC +/- 10% 40-70 Hz 12-50 VDC or 48-250 VDC Supply - input - output: 3.75 kV 24 VDC +/- 10% Note: With this DC-supply there is no isolation between supply and internal electronics. 2,5 VA -20°C to +60°C 0 - 90% RH, non-condensing Connections RC12. DC metering: 7-8 closed AC metering: 7-8 open Potentiometer, scale 0.4 to 6 Potentiometer, scale 5 to 50% Supply voltage connected Relay active 5% typ 0,1 % / °C 1-pole: 8 A - 250 VAC ohmic load Connections RV12. DC metering: 7-8 closed AC metering: 7-8 open

Open the catalog to page 1
RC12/RV12, current and voltage relays - 2

EMC and safety regulations. Emmision: EN 50 081 - 1 Immunity: EN 50 082 - 2 Safety: EN 60 730 Approvals: The units are produced in accordance with the CE og low voltage regulations. Ordering guide, RV12: Supply 12-50 VDC 24 VDC 24 VAC 115 VAC 230 VAC Mechanical dimensions: 38 mm C-mac Functional diagram: setpoint hysteresis input relay, ex. 1 Supply Relay Materials and weight: Example 1, undercurrent/voltage monitoring pin 6-7 not connected Example 2, overcurrent/voltage monitoring pin 6-7 connected Housing: NORYL-SE-1, grey, self-extinguishing Housing bottom: NORYL SE-1, GFN-2, black,...

Open the catalog to page 2

All COMADAN catalogs and technical brochures

  1. RM34

    2 Pages

Archived catalogs

  1. MS4201

    1 Pages

  2. Series CS/SC

    2 Pages

  3. TT22

    1 Pages