RC10/RV10, current and voltage relays
2Pages

{{requestButtons}}

Catalog excerpts

RC10/RV10, current and voltage relays - 1

RC10: Current monitoring RV10: Voltage monitoring 4 metering inputs in each module Adjustments for setpoint, hysteresis and time delay Selectable relay inversion, time delay and AC/DC mode DC supply or AC supplies up to 230 VAC Made in accordance with the and EMC regulations C-mac® current monitoring relay, type RC10, and voltage monitoring relay, type RV10, are universal metering relays, each supplied with 4 metering ranges, from 0,4 mA to 6 A or 40 mV to 600 V AC or DC, respectively. The input range is chosen by use of the appropriate input terminal, and the choice of AC/DC metering is made by connection/disconnection of terminal 8 to common (terminal 7). By means of 2 push-buttons on the back of the unit you can select relay and time-delay function. When the module is AC metering, the average value is metered, and the level adjustment is then calibrated to the r.m.s. value of a sinusoidal signal. Metering ranges, max. input signals and input impedances (Rin): Module Power consumption: Operation temp.: Humidity: Adjustments: Level: Hysteresis: Time-delay: Indications: Green LED: Red LED: Red LED: Accuracy, scale: Temp. coefficient: Max. load, relay: Common technical data: Supply voltage, AC: Supply frequency: Variable supply: Isolation voltage: Supply voltage, DC: 24, 115 and 230 VAC +/- 10% 40-70 Hz 12-50 VDC or 48-250 VDC Supply - input - output: 3.75 kV 24 VDC +/- 10% Note: With this DC-supply there is no isolation between supply and internal electronics. 2,5 VA -20°C to +60°C 0 - 90% RH, non-condensing Potentiometer, scale 0.4 to 6 Potentiometer, scale 5 to 50% Potentiometer, scale 0 to 10 sec. Supply voltage connected Set-point exceeded Relay active 5% typ 0,1 % / °C 1-pole: 8 A - 250 VAC ohmic load Connections RC10. DC metering: 7-8 open AC metering: 7-8 closed Connections RV10. DC metering: 7-8 open AC metering: 7-8 closed

Open the catalog to page 1
RC10/RV10, current and voltage relays - 2

Function selection: Button 1: Delay on operate / delay on release Button 2: Relay inversion Ex 1: 1 on, 2 off. Delay on release, when level drops below setpoint. Ex 2: 1 off, 2 on. Delay on operate, when level drops below setpoint. Ex 3: 1 off, 2 off. Delay on operate, when setpoint is exceeded. Ex 4: 1 on, 2 on. Delay on release, when setpoint is exceeded. Emmision: EN 50 081 - 1 Immunity: EN 50 082 - 2 Safety: EN 60 730 Approvals: The units are produced in accordance with the CE og low voltage regulations. Ordering guide, RV10: Supply 12-50 VDC 24 VDC 24 VAC 115 VAC 230 VAC Functional...

Open the catalog to page 2

All COMADAN catalogs and technical brochures

  1. RM34

    2 Pages

Archived catalogs

  1. MS4201

    1 Pages

  2. Series CS/SC

    2 Pages

  3. TT22

    1 Pages