RC10/RV10, current and voltage relays-1

RC10: Current monitoring RV10: Voltage monitoring 4 metering inputs in each module Adjustments for setpoint, hysteresis and time delay Selectable relay inversion, time delay and AC/DC mode DC supply or AC supplies up to 230 VAC Made in accordance with the and EMC regulations C-mac® current monitoring relay, type RC10, and voltage monitoring relay, type RV10, are universal metering relays, each supplied with 4 metering ranges, from 0,4 mA to 6 A or 40 mV to 600 V AC or DC, respectively. The input range is chosen by use of the appropriate input terminal, and the choice of AC/DC metering is made by connection/disconnection of terminal 8 to common (terminal 7). By means of 2 push-buttons on the back of the unit you can select relay and time-delay function. When the module is AC metering, the average value is metered, and the level adjustment is then calibrated to the r.m.s. value of a sinusoidal signal. Metering ranges, max. input signals and input impedances (Rin): Module Power consumption: Operation temp.: Humidity: Adjustments: Level: Hysteresis: Time-delay: Indications: Green LED: Red LED: Red LED: Accuracy, scale: Temp. coefficient: Max. load, relay: Common technical data: Supply voltage, AC: Supply frequency: Variable supply: Isolation voltage: Supply voltage, DC: 24, 115 and 230 VAC +/- 10% 40-70 Hz 12-50 VDC or 48-250 VDC Supply - input - output: 3.75 kV 24 VDC +/- 10% Note: With this DC-supply there is no isolation between supply and internal electronics. 2,5 VA -20°C to +60°C 0 - 90% RH, non-condensing Potentiometer, scale 0.4 to 6 Potentiometer, scale 5 to 50% Potentiometer, scale 0 to 10 sec. Supply voltage connected Set-point exceeded Relay active 5% typ 0,1 % / °C 1-pole: 8 A - 250 VAC ohmic load Connections RC10. DC metering: 7-8 open AC metering: 7-8 closed Connections RV10. DC metering: 7-8 open AC metering: 7-8 closed

 Open the catalog to page 1
RC10/RV10, current and voltage relays-2

Function selection: Button 1: Delay on operate / delay on release Button 2: Relay inversion Ex 1: 1 on, 2 off. Delay on release, when level drops below setpoint. Ex 2: 1 off, 2 on. Delay on operate, when level drops below setpoint. Ex 3: 1 off, 2 off. Delay on operate, when setpoint is exceeded. Ex 4: 1 on, 2 on. Delay on release, when setpoint is exceeded. Emmision: EN 50 081 - 1 Immunity: EN 50 082 - 2 Safety: EN 60 730 Approvals: The units are produced in accordance with the CE og low voltage regulations. Ordering guide, RV10: Supply 12-50 VDC 24 VDC 24 VAC 115 VAC 230 VAC Functional diagram:...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.