Catalog excerpts
1-phase and symmetrical 3-phase power monitoring Phase angle monitoring Analogue, pulse or relay outputs Galvanic separation, supply - input - output DC supply or AC supply voltages up to 400 VAC Made in accordance with the and EMC regulations PPV10 is a programmable multirange converter / isolation amplifier with 1- and 3-phase voltage input, one current input and current, voltage, pulse or relay outputs. The unit has a number of programmable input functions: Monitoring of phase angle or power consumption on single phase AC or DC loads. Monitoring of phase angle or power consumption on symmetrical 3-phase loads. The unit is supplied with 2 voltage range and 3 current range inputs, in order to achieve the highest possible accuracy. The unit can operate between 20 and 750 V input voltage and 150 mA to 6 A input current. If the metering current exceeds 6 A, you can use an external current transformer, and in this way it is also possible to monitor very big loads. The supply voltage for the unit is separated from the metering signal, this is particularly interesting, if there is a big variation of the metering voltages. You can select between 2 different output configurations: • Type A is supplied with analogue current output, programmable between 0 and 20 mA and analogue voltage output, programmable between -10 and +10 V. All parameters in the converter are programmable within the specified limitations (min. and max. input and output levels), giving the following possibilities: • Basic converter (0 to defined input range and standard output range, 0-20 mA, 4-20 mA or 0-10 V). • Converter with input and/or output offset, e.g. 200 to 800 W input and 8 to 15 mA output. • Bidirectional input range (phase angle), e.g. -50 to +40 deg. • Type B has the same outputs as type A, but in addition it is also supplied with pulse output, programmable to a maximum frequency of 10 kHz. The unit is supplied with 2 trimming potentiometers, which can be used to fine-adjust the metering range, if the unit is used with analogue outputs. In either case the potentiometers can be disabled, if adjustment is not required. If you want, you can order the unit with specific metering ranges, or you can program it yourself, by means of the C-mac programming software for PC and a small interface to connect between the PC and the module. • Bidirectional output range (only voltage output), e.g. -10 to +10 V. • Inverted function with or without offset, e.g. 300 to 200 W input and 4-20 mA output.
Open the catalog to page 1Supply voltage. 1: voltage input, phase 1, V;n > 75 V 2: voltage input, phase 1, V m< 75 V 3: voltage input, phase 2, V 75 V 4: voltage input, phase 2, V;n < 75 V 5: voltage input / phase 3, and load current, input 6: load current, output, Imax = 6 A 7: load current, output, Imax = 3 A 8: load current, output, Imax = 0,9 A output, common current output voltage output pulse output only( type PPV10-B) Programmable converter Connection examples: Analogue current output: Programmable ranges between 0 Analogue voltage output: Programmable ranges between Pulse outputs only( type PPV10-B):...
Open the catalog to page 2Mechanical dimensions: Materials: CYCOLOY C2100, grey Frontplate: CYCOLOY C2100, grey Terminal cover: CYCOLOY C2100, black Terminals: nickel plated brass Screws: nickel plated iron Housing base: C-mac Supply Programmable converter Programming connections and adjustments: Potentiometers P1 and P2. Programming connector CON. Connects to the PC via C-mac interface cable. PPV10-A and PPV10-B: The interface unit is internally battery powered, which means it is not necessary to connect any P1 = Offset fine adjust +/- 5% external supply voltage to the PPV unit during P2 = Span fine adjust +/- 5%...
Open the catalog to page 3Technical data: Supply voltage AC: Supply frequency: Supply voltage DC: Isolation voltages: Power consumption: Operation temp.: Humidity: Temp. coefficient: 24, 115, 230 and 400 VAC +/- 10% 40-70 Hz 12-50 VDC Supply - internal electronics: 3,75 kV Input - output: 2.5 kV 6 VA -20°C to +60°C 0-90% RH, non condensing < 0.003% /°C EMC data. Emission: Immunity: Safety: Approvals. EN 50 081 - 1 EN 50 082 - 2 EN 60 730 - 1 The module is produced in accordance with CE and high voltage regulations. Speed and accuracy. Conversion speed: Accuracy: at Iin > 5 A: Linearity: Resolution: in - out delay:...
Open the catalog to page 4All COMADAN catalogs and technical brochures
-
60 point LED bargraph AP560
1 Pages
-
kW transmitter FPA96
1 Pages
-
Power guard RP91
4 Pages
-
Test instrument MS4201
1 Pages
-
RT18, Star-delta relay
1 Pages
-
RD20, amplifying relay
1 Pages
-
RR10, tachometer relay
2 Pages
-
RF20, frequency relay
2 Pages
-
RL10/RL11/RL12
2 Pages
-
RC15/RC20, current relays
2 Pages
-
RM34
2 Pages
-
MP92, torque monitor
2 Pages
-
RP33, 3-phase monitoring
1 Pages
-
RP32, phase sequence relay
1 Pages
-
RP10, 1-phase monitoring
1 Pages
-
Tachometer converter
2 Pages
-
Programmable converter PMR10
4 Pages
-
Programmable converter PCV10
4 Pages
Archived catalogs
-
MS4201
1 Pages
-
Series CS/SC
2 Pages
-
RV20, voltage relay
2 Pages
-
RP91, power monitoring relay
4 Pages
-
Series FP, 3-phase relays
3 Pages
-
TT22
1 Pages
-
FPA90, Power converter
2 Pages
-
Temperature sensors
2 Pages
-
Automatic timers RT1X
2 Pages
-
Phase asymmetry relay RP31
1 Pages
-
Power supply series PSD
1 Pages