1. Catalogs
  2. COMADAN
  3. Programmable converter PCV10

Programmable converter PCV10

Programmable converter PCV10

Programmable converter PCV10

Product catalog summary
Overview: The C-mac® PCV10 is a programmable converter designed for AC/DC current and voltage inputs, with capabilities for frequency monitoring and various output configurations. It offers galvanic separation and can be powered by DC or AC supply voltages up to 400 VAC.
Specifications: The PCV10 supports current inputs from 15 µA to 10 A and voltage inputs from 10 mV to 1500 V. It can monitor frequencies up to 5 kHz. The device provides analogue or pulse outputs and ensures galvanic separation between supply, input, and output.
Input and Output Configurations: The unit can be programmed for various input ranges and output configurations. Type A offers analogue current and voltage outputs, while Type B includes pulse outputs. Outputs are programmable between 0-20 mA and -10 to +10 V.
Programming and Adjustments: The PCV10 can be programmed using C-mac software and a PC interface. It includes potentiometers for fine adjustments of offset and span, which can be enabled or disabled as needed. Programming can be done with or without supply voltage connected.
Technical Data: The device supports a wide range of current and voltage inputs with specific metering ranges and maximum inrush currents. It operates within a temperature range of -20°C to +60°C and a humidity range of 0-90% RH. The unit complies with EMC and safety standards.
Performance: The PCV10 offers high accuracy and linearity, with conversion speeds of 150 msec for AC inputs and 20 msec for DC inputs. It provides a resolution between 0.037% and 0.1%, depending on the programmed range.
Installation and Ordering: The device requires a minimum distance of 5 mm between modules when mounted in a control panel. It can be ordered with or without pre-programmed ranges, and various supply voltage options are available.
See more

Catalog excerpts

Programmable converter PCV10-1

AC/DC current inputs from 15 µA to 10 A AC/DC voltage inputs from 10 mV to 1500 V Frequency monitoring up to 5 kHz Analogue or pulse outputs Galvanic separation, supply - input - output DC supply or AC supply voltages up to 400 VAC Made in accordance with the and EMC regulations PCV10 is a multirange converter / isolation amplifier All parameters in the converter are programmable within the with current, voltage and pulse inputs and current, volt- specified limitations (min. and max. input and output levels), age, pulse or relay outputs. giving the following possibilities: The unit is supplied with 3 current and 3 voltage input mA Output 20 connections, which makes it possible to program any in• Basic converter, (0 to put range between 15 µA and 10 A or 15 mV and 16 defined input range and 1000VAC/1500 VDC. With DC-inputs it is possible to 12 standard output range, monitor both positive and negative signals. 8 0-20 mA, 4-20 mA or With AC inputs the converter monitors the RMS value 4 0-10 V). of the signal, which means the signals are converted Input 0 without any errors, no matter which shape they have. 0 20 40 60 80 100% The unit can also be programmed with frequency input, mA Output 20 where the same input connections are used. The fre• Converter with input quency of the input signal is then monitored instead of 16 and/or output offset, the analogue level. 12 e.g. 12 to 50 VDC input You can select between 2 different output configura8 and 8 to 15 mA output. tions: 4 • Type A is supplied with analogue current output, programmable between 0 and 20 mA and analogue voltage output, programmable between -10 and +10 V. • Type B has the same outputs as type A, but in addition it is also supplied with pulse output, programmable to a maximum frequency of 10 kHz. The unit is supplied with 2 trimming potentiometers, which can be used to fine-adjust the metering range, if the unit is used with analogue outputs. In either case the potentiometers can be disabled and fixed values selected, if adjustment is not required. If you want, you can order the unit with specified metering ranges, or you can program it yourself, by means of the C-mac programming software for PC and a small interface to connect between the PC and the module. • Bidirectional input range (only DC inputs), e.g. -50 to +300 mA. • Bidirectional output range (only voltage output), e.g. -10 to +10 V. • Inverted function with or without offset, f.inst 150 to 20 VAC input and 4 to 20 mA output.

 Open the catalog to page 1
Programmable converter PCV10-2

Supply voltage. input common output common current output voltage output pulse output (type PCV10-B only) Programmable converter Current inputs: Analog current output: Programmable ranges Connection drawings: Voltage inputs: Analog voltage output: Programmable ranges Pulse outputs type PCV10-B only): Eksternal load: Eksternal load: Pulse output.

 Open the catalog to page 2
Programmable converter PCV10-3

Mechanical dimensions: Materials: CYCOLOY C2100, grey Frontplate: CYCOLOY C2100, grey Terminal cover: CYCOLOY C2100, black Terminals: nickel plated brass Screws: nickel plated iron Housing base: C-mac Supply Programmable converter Programming connections and adjustments: Potentiometers P1 and P2. Programming connector CON. Connects to the PC via C-mac interface cable. PCV10-A and PCV10-B: The interface unit is internally battery powered, which means it is not necessary to connect any P1 = Offset fine adjust +/- 5% external supply voltage to the PCV unit during P2 = Span fine adjust +/- 5% programming....

 Open the catalog to page 3
Programmable converter PCV10-4

Technical data: Supply voltage AC: Supply frequency: Supply voltage DC: Isolation voltages: Power consumption: Operation temp.: Humidity: Temp. coefficient: 24, 115, 230 and 400 VAC +/- 10% 40-70 Hz 12-50 VDC Supply - internal electronics: 3,75 kV Input - output: 2.5 kV 6 VA -20°C to +60°C 0-90% RH, non condensing < 0.003% /°C Steady light = supply ON Flashing = programming mode Current inputs: Terminals 1-2: Metering ranges (DC) 290 mA to 10A Rin = 10 mW Max. inrush current (10 sec): 20 A Terminals 1-3: Metering ranges (DC) 8 mA to 290 mA Rin = 2.7 W Max. inrush current (10 sec): 1A Terminals...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.