FCD25 programmable double limit switch

FCD25 programmable double limit switch

FCD25 programmable double limit switch

Product catalog summary
Overview: The FCD25 is a programmable double limit switch designed for monitoring current signals, particularly from 2-wire transmitters with 4-20 mA output. It features analogue and digital inputs, relay outputs, and programmable setpoints, making it suitable for various industrial applications.
Specifications:
  • Supply Voltage: 24 VDC +/- 10%
  • Current Consumption: Max. 60 mA
  • Operating Temperature: -15°C to +50°C
  • Humidity: 0 - 90% RH, non-condensing
  • Relay Load: 5 A - 250 VAC, ohmic load
  • Analogue Input: 0(4) - 20 mA, 70 Ohm
  • Digital Inputs: Positive logic (5-30 VDC), Negative logic (0 V)
  • Dimensions: 58 x 36 x 86 mm
  • Weight: 200 g
Key Features:
  • Analogue Input: Programmable for 0-20 mA or 4-20 mA with adjustable input range.
  • Digital Inputs: Configurable for positive or negative logic, active low or high.
  • Relay Outputs: Two relays with NO-contacts, programmable for activation or release upon limit exceedance.
  • Setpoints: Two independent setpoints, programmable as min or max, selectable as a percentage of the range.
  • Start-up Timer: Prevents alarms during unstable start-up phases.
  • Reaction Delay: Programmable delay to avoid false alarms from short exceedances.
  • Hysteresis: Adjustable hysteresis band for both limits, with auto-reset functionality.
Programming and Parameters:
  • Access programming mode via 'Mode' button, navigate parameters with 'Up' and 'Down'.
  • 11 user-programmable parameters including input type, setpoint types, hysteresis, polarity, auto-shutdown, and logic configuration.
  • Directly accessible parameters include start-up timer, setpoint percentages, and reaction delays.
Compliance and Safety:
  • EMC and Safety Regulations: EN 50 081-1, EN 50 082-2, EN 60 730
  • CE and low voltage regulation compliant.
Additional Features:
  • Peak Detectors: Max and min peak detectors with reset functionality.
  • Example Application: Suitable for monitoring power consumption in AC motors, with programmable start-up timer to filter out initial power peaks.
See more

Catalog excerpts

FCD25 programmable double limit switch-1

Double limit switch FCD25 Programmable double limit switch Analogue input 0(4) - 20 mA Selectable min- or max limits Start-up and reaction timer Supply voltage 24 VDC Programmable inputs Made in accordance with the and EMC regulations FCD25 is a double limit switch for monitoring of current signals, f.inst. from 2-wire transmitters with 4-20 mA output or other units with current output. Analogue input The analogue input is programmable for either 0-20 mA or 4-20 mA. The input range is adjustable too, down to 10 mA for 100% input range. Digital inputs The digital inputs are programmable for either positive or negative logic. The inputs are programmed for either active low or active high. At positive logic, input signals from 5-30 VDC are accepted. At negative input, the input is connected to ground f.inst. with a contact or an NPN output from a sensor. Relay outputs The unit is supplied with 2 relays, one for each limit. Both relays have NO-contacts, and both of them are programmable for either activation or release, when the set limit is exceeded. The alarms can be reset with the "Mode" button or input "S1". Setpoints The unit have two independent setpoints, programmable as either min. or max. setpoint. The setpoints are selected as a percentage of the range. It is possible to cancel the monitoring with the input S2. Start up timer The start up timer is used if the start-up of a process is unstable and you do not want an alarm during start-up. It is activated when the input signal exceeds approx. 5 % of the metering range. If the start-up timer is set at 0, this function is cancelled. Reaction delay For each setpoint you can program a reaction delay in order to avoid alarm in case of only a short exceeding of the setpoint. Hysteresis The hysteresis can be used on both limits. The hysteresis band is always above a min-limit and under a max-limit. If the hysteresis function is used, an internal auto-reset function is used. If you use the hysteresis at a min. setpoint, at the input signal goes to zero, you can reset the alarm by pressing the "Mode" button or activate input S1. Technical data: 24 VDC +/- 10% max. 60 mA -15°C to +50°C 0 - 90% RH, non-condensing 1-pole: 5 A - 250 VAC, ohmic load 0(4) - 20 mA, 70 Ohm pos. logic: 5-30 VDV neg. logic: 0 V External reset Alarm blocking 200 g 58 x 36 x 86 mm Supply voltage: Current consumption: Operating temp.: Humidity: Max. load, relays: Analogue input: Digital inputs: Indput S1: Input S2: Veight: Dimensions: EMC og safety regulations. Emmision: EN 50 081 - 1 Immunity: EN 50 082 - 2 Safety: EN 60 730 Approvals: The units are produced in accordance with the CE og low voltage regulations.

 Open the catalog to page 1
FCD25 programmable double limit switch-2

Selection of parameters. In the scheme you can see the 11 user programmable parameters. To get into the programming mode, press ‘Mode’ until the ‘Setup’-LED is on and the display shows ‘P00’. Then you used the ‘Up’ and ‘Down’ for selection of the wanted parameter followed by ‘Mode’. Now the wanted parameter is selected, and you can change the value by pressing ‘Up’ and ‘Down’. The new value is stored by pressing ‘Mode’, and then you can select a new parameter. To end the programming mode you select Par. no. 00 and when you press ‘Mode’ you return to normal function. Start-up timer Reaction delay...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.