Catalog excerpts
60 point LED bargraph AP560 Selectable bar or dot display Current or voltage input Out of range indication Upper and lower limit indication Front panel 24 x 96 mm Made in accordance with the C€ and EMC regulations AP560 has a selectable 60 point bar or dot indication. 2 out of range dots indicates if the input signal is smaller than 0% or higher than 100% of the selected display range. It is also possible to adjust 2 visual limit indications. If the actual input signal exceeds the set limits, the active bar dots will flash, and the set dots is on steady light. MIN, MAX and UNIT indication is placed behind the front label for horisontal or vertical graph. Technical data: Supply voltage: electronics. Power consumption: Operating temp.: Humidity: Protection: Temp.coefficient: Metering ranges: Input impedances: Range adjustment: Dot size: Mech. dimensions: LxWxD: Panel cut-out: Weight: Materials: Connections: 9-36 VDC / 9-26 VAC The supply voltage is galvanically isolated from the internal (test voltage 4 kV AC) 1 VA -10°C to +50°C 0 - 90% RH, non-condensing IP 54 max. 0,01%/°C 0-100 mV, 0-1 V, 0-10 V, 0-20 mA and 4-20 mA. Voltage metering: >100 kQ Current metering: typ. 75 Q Offset (minimum scale): 0% potentiomer adjustable from 0 - 80% of selected metering range. Span (maximum scale): 100% potentiometer adjustable from 50% to 250% of the metering range. 1x1 mm red LED. 24 x 96 x 66 mm. 21 x 90 mm. 100 g. NORYL2, SE1 screw terminals, max. 1,5 □ mm. EMC and safety regulations. Emmision: EN 50 081 - 1 Approvals: The units are produced in accordance with the CE and low voltage regulations. 1: On dip 1-2-3 select the wanted input range. 2: Connect the wanted minimum signal to the input and adjust for wanted minimum display with 0% potmeter. 3: Connect the wanted maximum signal to the input and adjust for wanted maximum display with 100% potmeter. 4: Check min and max display and readjust if needed. 5: Select display options (bar/dots and normal/reverse) on dip 4-5. 6: Adjust min and max limits on LIM1 and LIM2 potmeters if wanted. CCComadan WE FIRE IN CONTROL Tel.: +45 86 44 78 77 • Mail: sales@comadan.com • www.comadan.com
Open the catalog to page 1All COMADAN catalogs and technical brochures
-
kW transmitter FPA96
1 Pages
-
Power guard RP91
4 Pages
-
Test instrument MS4201
1 Pages
-
RT18, Star-delta relay
1 Pages
-
RD20, amplifying relay
1 Pages
-
RR10, tachometer relay
2 Pages
-
RF20, frequency relay
2 Pages
-
RL10/RL11/RL12
2 Pages
-
RC15/RC20, current relays
2 Pages
-
RM34
2 Pages
-
MP92, torque monitor
2 Pages
-
RP33, 3-phase monitoring
1 Pages
-
RP32, phase sequence relay
1 Pages
-
RP10, 1-phase monitoring
1 Pages
-
Tachometer converter
2 Pages
-
Programmable converter PPV10
4 Pages
-
Programmable converter PMR10
4 Pages
-
Programmable converter PCV10
4 Pages
Archived catalogs
-
MS4201
1 Pages
-
Series CS/SC
2 Pages
-
RV20, voltage relay
2 Pages
-
RP91, power monitoring relay
4 Pages
-
Series FP, 3-phase relays
3 Pages
-
TT22
1 Pages
-
FPA90, Power converter
2 Pages
-
Temperature sensors
2 Pages
-
Automatic timers RT1X
2 Pages
-
Phase asymmetry relay RP31
1 Pages
-
Power supply series PSD
1 Pages