Coltlite CL High performance natural louvred ventilator
Open the catalog to page 1COLTLITE: NATURAL VENTILATION AT ITS BEST AND IT’S GETTING EVEN BETTER! Coltlite is a natural louvred ventilator suitable for natural day to day and smoke control ventilation. It conforms to EN 12101-2 and EN 14351-1 and is CE marked. It can provide inlet and extract ventilation as well as the entry of natural daylight for most kinds of industrial and commercial buildings. It achieves high acoustic, thermal and aerodynamic performance. It is suited for installation into the façade. Its form and function make it particularly suited to naturally ventilated buildings where good aerodynamic and measured...
Open the catalog to page 2HIGH PERFORMANCE FEATURES AND BENEFITS A WIDE RANGE OF APPLICATIONS Coltlite has high aerodynamic, acoustic and thermal performance, and has a high resistance to the effects of fire. Full performance data is given later on in this leaflet. Coltlite is classed as a dual purpose ventilator, providing both day to day and smoke control ventilation. It can also be installed either for low level air inlet or for high level extract. Coltlite is also often used as a termination piece for large ducted or air handling systems. Glass versions allow the entry of natural daylight, and a wide range of infill...
Open the catalog to page 3PRODUCT OVERVIEW Please refer to the following pages for the full technical information relating to these products. Image: Aboriginal Centre, Sydney. Type: CLS Non-thermally broken extruded aluminium outer frames, non-thermally broken louvre frames. Double glazed louvres with 28mm thick clear float, toughened or laminated glass. Overall frame depth 47mm, frame face width 40mm. Thermally broken extruded aluminium outer frames and louvre frames. Double glazed louvres with 28mm thick clear float, toughened or laminated glass. Overall frame depth 47mm, frame face width 40mm. Non-thermally broken...
Open the catalog to page 4OPTIONS Image: Auckland Art Gallery, New Zealand. Type: CLS 45 Glass louvres are manufactured as standard in single and double glazed options. There is the choice of glass with a thickness of between 4 - 8 mm for the double glazed systems, with an overall glass thickness of 28mm or 34mm (only CLST), and glass with a thickness of between 8, 10 and 12 mm for the CLS and CLS 45 single glazed versions. CLN has non-thermally broken outer and louvre frames. CLS and CLS 45 have nonthermally broken outer frames and frameless glass louvres. Louvres can also be provided with insulated aluminium sections....
Open the catalog to page 5SUMMARY TECHNICAL INFORMATION COLTLITE CLT VENT OVERALL WIDTH *Note (1) LOUVRE PIVOTS Standard: centre pivoted. Other types on request. MAX. LOUVRE OPENING ANGLE Max. 90° (depends on the drive selected) FACE FRAME WIDTH Insulated glazing (2- or 3 panes) or composite infill panels STANDARD GLASS Manual, 24v dc or 230v ac electric or pneumatic RESISTANCE TO WEATHER (EN 12208) *Note (4) RESISTANCE TO WIND (EN 12210) *Note (4) These data are indicative only. The ventilator should be designed to resist the design wind loads. BLADE PITCH (OR LOUVRE HEIGHT) *Note (3) *(1) Outer frame dimensions. For...
Open the catalog to page 6SUMMARY TECHNICAL INFORMATION COLTLITE CLN Non-thermally broken extruded aluminium outer frames, non-thermally broken louvre frames. Double glazed louvres with 28mm thick clear float, toughened or laminated glass. VENT OVERALL WIDTH *Note (1) VENT OVERALL HEIGHT *Note (2) BLADE PITCH (OR LOUVRE HEIGHT) *Note (3) LOUVRE PIVOTS Standard: centre pivoted. Other types on request. MAX. LOUVRE OPENING ANGLE Max. 90° (depends on the drive selected) FACE FRAME WIDTH Insulated glazing (2 or 3 panes) or composite infill panels STANDARD GLASS Manual, 24v dc or 230v ac electric or pneumatic RESISTANCE TO...
Open the catalog to page 7SUMMARY TECHNICAL INFORMATION COLTLITE CLS VENT OVERALL WIDTH *Note (1) LOUVRE PIVOTS Standard: centre pivoted. Other types on request. MAX. LOUVRE OPENING ANGLE Max. 90° (depends on the drive selected) FACE FRAME WIDTH Single glazing GLASS TYPES Toughened, Heat toughened or laminated (from float, toughened - laminated or toughened) with polished edge Manual, 24v dc or 230v ac electric or pneumatic RESISTANCE TO WEATHER (EN 12208) *Note (4) These data are indicative only. The ventilator should be designed to resist the design wind loads. BLADE PITCH (OR LOUVRE HEIGHT) *Note (3) *(1) Outer frame...
Open the catalog to page 8SUMMARY TECHNICAL INFORMATION COLTLITE CLS 45 Non-thermally broken extruded aluminium outer frames. Frameless single glazed controllable louvres, closing flush, with either 8mm, 10 mm or 12 mm thick toughened bevelled glass. VENT OVERALL WIDTH *Note (1) VENT OVERALL HEIGHT *Note (2) BLADE PITCH (OR LOUVRE HEIGHT) LOUVRE PIVOTS Standard: centre pivoted. Other types on request. MAX. LOUVRE OPENING ANGLE Max. 90° (depends on the drive selected) FACE FRAME WIDTH Single glazing GLASS TYPES Toughened with beveled polished edge RESISTANCE TO WEATHER (EN 12208) *Note (4) RESISTANCE TO WIND (EN 12210)...
Open the catalog to page 9SUMMARY TECHNICAL INFORMATION COLTLITE CLST VENT OVERALL WIDTH *Note (1) LOUVRE PIVOTS Standard: centre pivoted. Other types on request. MAX. LOUVRE OPENING ANGLE Max. 90° (depends on the drive selected) FACE FRAME WIDTH Insulated glazing (double-pane stepped glass) GLASS TYPES Toughened outside with polished edge; float, laminated or toughened glass inside Manual, 24v dc or 230v ac electric or pneumatic RESISTANCE TO WEATHER (EN 12208) *Note (4) These data are indicative only. The ventilator should be designed to resist the design wind loads. BLADE PITCH (OR LOUVRE HEIGHT) *Note (3) *(1) Outer...
Open the catalog to page 10SUMMARY TECHNICAL INFORMATION COLTLITE CLET Thermally broken extruded aluminium outer frames and louvre blades. Fixed louvre height without louvre frame VENT OVERALL WIDTH *Note (1) VENT OVERALL HEIGHT *Note (2) BLADE PITCH (OR LOUVRE HEIGHT) LOUVRE PIVOTS Centre pivoted MAX. LOUVRE OPENING ANGLE Max. 90° (depends on the drive selected) FACE FRAME WIDTH Thermally broken aluminium extruision with optional additional insulation Manual, 24v dc or 230v ac electric or pneumatic RESISTANCE TO WEATHER (EN 12208) *Note (3) Diagram shows optional insulation RESISTANCE TO WIND (1) (EN 12210) *Note (3)...
Open the catalog to page 112 Pages
32 Pages
2 Pages
8 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
5 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages