video corpo

RIGP

RIGP
1 / 24 PagesView full catalog

RIGP

Product catalog summary
Technical Specifications:
The document outlines the specifications for the RIGP series globoidal cam indexing tables, available in models RIGP 04, RIGP 06, and RIGP 09. These tables offer multiple stop options and feature a large output flange supported by a preloaded cross-roller bearing, a stationary center-post through-hole, and a nitrided steel cam. They are lubricated for life with oil bath lubrication, and 3D models are accessible online.
Repeatability and Loads:
A diagram and table illustrate repeatability concerning the dial plate diameter, with suggested maximum diameters for each model. The document also details the axial and radial forces, as well as the overturning moment, with formulas for calculating these forces.
Sizing and Inertia:
An Excel file is available for application sizing. Inertia values are provided for different cycle times and motor frequencies (50 Hz and 60 Hz), with specific order codes for each configuration.
Cycle Times and Motor Power:
Cycle times are specified for continuous motion, with adjustments for cycle-on-demand applications. Specifications for motor power requirements are provided, detailing the power needed for different numbers of stops.
Connection Diagrams and Assembly:
Connection diagrams for motor setup are included, detailing wiring for normal and brake motors at different voltages. Instructions for the assembly position of the table are also provided.
Dimensions and Sensors:
Detailed dimensions for each model are provided. Information on the operation of proximity sensors and phase cams is included, explaining the use of phase cams and sensors to control motor stopping.
Standards and Compliance:
The document states compliance with international metric system SI, general manufacturing tolerances according to UNI – ISO 2768-1 UNI EN 22768-1, and illustrations and drawings according to UNI 3970 (ISO 128-82).
Recommendations:
For emergency-stop conditions, the use of an inverter with calculated deceleration times is recommended to ensure effective stopping. Adjustments to the timing bands of phase cam B are advised if the motor does not stop correctly in the dwell phase.
See more

Catalog excerpts

RIGP-1

GLOBOIDAL CAM INDEXING TABLE TAVOLA INTERMITTENTE A CAMMA GLOBOIDALE RUNDSCHALTTISCH MIT GLOBOIDKURVE TABLE D’INDEXAGE CAME GLOBIQUE MESA INTERMITENTE CON LEVA GLOBOIDAL http://www.cofil.com - E-mail: cofil@cofil.com Via G. Rossini 26 - 24040 Casirate D’Adda Bg IT Phone +39 0363 3251 - Fax +39 0363

 Open the catalog to page 1
RIGP-3

Summary - Sommario - Inhaltsverzeichnis - Index - Sumario Sizing software - Programma di dimensionamento - Dimensionierungs Programm - Programme de dimensionnement - Programa de dimensionamiento Le unità di misura sono conformi al sistema metrico internazionale SI Le tolleranze generali di fabbricazione sono secondo UNI – ISO 2768-1 UNI EN 22768-1 Illustrazioni e disegni secondo UNI 3970 (ISO 128-82) Il metodo di rappresentazione dei disegni convenzionale La Colombo Filippetti Spa si riserva il diritto di effettuare in qualsiasi momento modifiche utili a migliorare i propri prodotti. I valori...

 Open the catalog to page 3
RIGP-4

RIGP Grandezze: • RIGP 04 • RIGP 06 • RIGP 09 Größen: • RIGP 04 • RIGP 06 • RIGP 09 • Large output flange for easy connection to the dial plate • Output flange supported by oversized preloaded cross-roller bearing • Stationary center-post through-hole • Maximum station-to-station accuracy • Nitrided steel cam • Oil bath lubrication for life • Ampia flangia uscita moto per agevolare il calettamento di dischi • Uscita moto supportata da ralla surdimensionata a rulli incrociati • Mozzo centrale fisso con foro passante • Massima precisione di posizionamento da stazione a stazione • Camma globoidale con...

 Open the catalog to page 4
RIGP-5

DONNEES TECHNIQUES Dimension: • RIGP 04 • RIGP 06 • RIGP 09 Stations: 2,3,4,5,6,8,10,12 • Grande flasque de sortie mouvement pour faciliter le calage des plateaux • Sortie mouvement avec support butee — de grande dimension a galets croises • Moyeu central fixe pourvu d'orifice JO passant • Precision maximale de positionnement LU d'une station a l'autre • Came globique avec profil en acier traite et nitrure • Lubrification a vie en bain d'huile DATOS TECNICOS Dimensiones: • RIGP 04 • RIGP 06 • RIGP 09 Estaciones: 2,3,4,5,6,8,10,12 • Brida de salida de movimento para facilitar el acoplamiento de...

 Open the catalog to page 5
RIGP-6

RIGP LOADS ON OUTPUT FLANGE Fa = Axial force (N) Fr = Radial Force (N) Mr = Overturning moment (Nm) CARICHI SUL DIVISORE Fa = Forza assiale (N) Fr = Forza radiale (N) Mr = Momento ribaltante (Nm) LASTEN AUF DEM TEILGERAT Fa = Langskraft (N) SIZING SOFTWARE To easily size the application, an Excel file is available for download from our web sites. O c PROGRAMMA DI DIMENSIONAMENTO Per un piu facile dimensionamento dell'applicazione, e possibile utilizzare un foglio elettronico formato Excel disponibile sui ns. siti nella sezione download. DIMENSIONIERUNGS PROGRAMM Fur eine...

 Open the catalog to page 6
RIGP-7

CHARGES SUR LE DIVISEUR Fa = Force axiale (N) Fr = Force radiale (N) Mr = Moment renverse (Nm) PROGRAMME DE DIMENSIONNEMENT Pour un dimensionnement plus facile de l'application, il est possible d'utiliser un fichier electronique en format Excel disponible sur nos sites a la section 'Telechargement'. CARGAS EN EL DIVISOR Fa = Fuerza axial (N) Fr = Fuerza radial (N) Mr = Momento de vuelco (Nm) b, dr = Distancia (m) Mr = Fr . dr Mr = Fa . b O PROGRAMA DE DIMENSIONAMIENTO Para que el dimensionamiento de la aplicacion sea mas facil, es posible utilizar una hoja electronica en formato Excel,...

 Open the catalog to page 7
RIGP-8

RIGP Stops • The cycle time 'ts' is for continuous motion. For cycle-on-demand applications the value 'ts' is affected by the delay of the equipments connected. Il tempo di ciclo 'ts' e valido per un funzionamento in continuo. Per posizionamento a consenso il tempo 'ts' e modificato dai ritardi delle apparecchiature collegate. Die Zykluszeit 'ts' steht fur kontinuierlichen Lauf bzw. Bewegung. Fur eine Start-Stopp-Bewegung wird der Wert 'ts' durch die Verwendung der Software verzogert. Le temps de cycle 'ts' est valable pour un fonctionnement en continu. Pour un fonctionnement en temporise, le...

 Open the catalog to page 8
RIGP-9

RIGP Stops DESIGNATION • DESIGNAZIONE • BEZEICHNUNG • DESIGNATION • DESIGNACION IM phase cams • camma di fase • phasennocken • came de phase • leva de fase E E-CAM HCS N normal motor • motore normale • normal Motor • moteur normal • motor standard/normal Z brake motor • motore autofrenante • Bremsmotor • moteur autofreinant • motor freno E 50 Hz european frequence • frequenza europea • Europaische Frequenz • frequence europeenne • frecuencia Europeo U 60 Hz american frequence • frequenza americana • amerikanische Frequenz • frequence americain • frecuencia de America no. of stops • divisioni...

 Open the catalog to page 9
RIGP-10

RIGPCYCLE TIMES WITH MOTOREDUCER • TEMPI DI CICLO MOTORIDUTTORE ZYKLUSZEITEN MIT UNTERSETZERMOTOR TEMPS DE CYCLE AVEC MOTOREDUCTEUR • TIEMPOS DE CICLO CON MOTORREDUCTOR ir Reduction ratio - Rapporto di riduzione - Untersetzungsverhaltnis - Rapport de reduction - Relacion de reduccion v Reducer speed - Velocita riduttore - Drehzahl der Getriebe - Vitesse reducteur -Velocidad reductor ts Cycle time - Tempo ciclo - Zykluzeit - Temps du cycle - Tiempo de ciclo tm Index time - Tempo di spostamento - Schaltzeit - Temp de deplacement - Tiempo de emplazamiento • For optimum performance of...

 Open the catalog to page 10
RIGP-11

MOTOR POWER • POTENZA MOTORE • LEISTUNG MOTOR PUISSANCE MOTEUR • POTENCIA MOTOR 50 Hz Brake 230V a.c. - Freno 230V a.c. - Bremse 230V a.c. - Frein 230V a.c. - Freno 230V a.c.

 Open the catalog to page 11
RIGP-12

Inductive micro switch

 Open the catalog to page 12
RIGP-13

Inductive micro switch REDUCER: RMI40 MOTOR: BRAKE MOTOR

 Open the catalog to page 13
RIGP-14

RIGP Inductive micro switch E-Cam RIGP 06

 Open the catalog to page 14
RIGP-15

Inductive micro switch E-Cam

 Open the catalog to page 15
RIGP-16

RIGP Inductive micro switch

 Open the catalog to page 16
RIGP-18

RIGP PROXIMITY SENSORS & PHASE CAMS OPERATION SENSORE PROXY E CAMMA DI FASE • The signal to stop the motor is made by way of two phase cams A & B and two (2) proximity sensors (PNP n.o.) designated as SA and SB (Fig. 1,2) • Phase cam A is fixed on the input shaft of the indexer with a key and will have a rounded cutout in the diameter designated as DW. This cutout corresponds with the dwell period of the indexer. • When the output signal of sensor SA (corresponding to phase cam A) is low, the unit is positioned in dwell DW. • The second phase cam, noted as phase cam B is adjustable: the gap DS...

 Open the catalog to page 18
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.