Catalog excerpts
— Excellent solution for nuclear radiation measurement R60N Neutron Gamma Radiometer One sensor can detect neutron and γ ray the same time Gamma suppression ratio:1000:1(137Cs) Same volume,the sensitivity is 20 times higher than the 3He sensor Description R60N neutron gamma radiometer, adoption of Coliy patent H type neutron sensor, a new sensor single sensor to measure and distinguish the neutron and gamma ray. This is because the neutron ray into the sensor, the voltage signal amplitude is much higher than the voltage signal amplitude gamma rays, with independent neutron, gamma measurement channels, comprehensive coverage of the detection of neutrons and gamma rays. The H type sensor for cube structure, minimum error 4π angle response, high detection efficiency, fast response, gamma inhibition ratio up to 1000:1. Much higher than that of 6LiI (Eu) 3He scintillation crystal 20:1,sensor sensitivity 20 times in the same volume. The advantages of both 3He sensor and 6LiI (Eu) scintillation crystal are presented,the energy response range of neutron is 0.025eV-16MeV, and the energy response range of gamma is 50keV-3MeV. The R60N type radiometer using Coliy unique circuit design and software algorithm, which can display the detection data of neutron and gamma rays, and a variety of measurement data: real time value, maximum value, minimum value, alarm threshold, but also through the time domain waveforms show the dose rate, dose rate instrument automatically products are accumulated, the European CE certification and ISO9001 quality certification. Coliy Technology GmbH
Open the catalog to page 1— Excellent solution for nuclear radiation measurement Application Monitoring of work areas involving neutron beams, such as research reactors, particle accelerators, etc The utility model is used for fast searching of gamma ray neutron source and application of radiation disposal environment Nuclear facilities, nuclear supervision and radiation protection of enterprises and institutions concerned with sources The hospital, oil well logging and monitoring control of regional industrial testing personnel Environmental monitoring departments perform official duties, disease control, health...
Open the catalog to page 2— Excellent solution for nuclear radiation measurement Graphical interface operating system Coliy develops a set of revolutionary graphical interface operating system which breaks the style of traditional instrument, and the customer can use the R60N like using smart-phone, greatly simplifies the operation process. Large and clarity touch screen can display real value, maximum, minimum 超大全屏触摸屏可显示多种数 alarm据:实时值、最大值、最小值、 threshold, % and so on. 报警阈值、%等,仪器自动进行剂 量率累计 。 Neutron and gamma ray shows at the same time The data of neutrons and gamma rays are clearly and clearly displayed. The user...
Open the catalog to page 3Radiation Scanner — Excellent solution for nuclear radiation measurementColiy patented H type sensor One sensor can detect neutron and y ray the same time The advantages of both 3He sensor and 6LiI (Eu) scintillation crystal are presented Omnidirectional sensors, basically without angular response error At the same volume, the sensitivity is 20 times higher than the 3He sensor Gamma suppression ratio 1000:1 (137Cs) Neutron energy response range 0.025eV~16MeV Gamma energy response range 50keV~3MeV Coliy Technology GmbH
Open the catalog to page 4Radiation Scanner The trademark and product name in the file belong to Coliy Technology GmbH. Contents in this file for reference only. The actual specification of the product is subject to the client’s contract. Revision!, Published: NSF-English-01-06 &OLIY Technology GmbH Coliy Technology GmbH www.coliy.com
Open the catalog to page 5All Coliy Technology GmbH catalogs and technical brochures
-
R800 Radiation Scanner
2 Pages
-
Moisture analyzer