Cable glands and connectors
20Pages

{{requestButtons}}

Catalog excerpts

Cable glands and connectors - 1

www.cmp-products.com www.cmp-products.ru CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD • ATEX 95 & BEYOND Triple Certified Single Solution - Three Forms of Protection

Open the catalog to page 1
Cable glands and connectors - 2

Cable Glands For Hazardous Areas Leading the Way in Hazardous Areas CMP Products has an international reputation for Quality and Reliability in various sectors of Industry and is highly regarded as the Specialist in the field of Industrial and Hazardous Area Cable Gland and Cable Connector design and manufacture. CMP Products maintains its position as a leader in the business of terminating cables through its commitment to meeting customer needs, providing solutions, whether standard or special, that pay close attention to the heart of application and installer requirements, and in addition...

Open the catalog to page 2
Cable glands and connectors - 3

Triton CDS (T3CDS) Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland 05 TECHNICAL DATA TEMPERATURE RATING:-60°C to +130°C DELUGE PROTECTION: DTS01:91 CABLE TYPE: Aluminium Strip Armour (ASA), Screened Flexible Wire Braid (e.g. CY / SY), Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Wire Braid Armour (e.g. SWB), Armored & Jacketed SEALING AREA(S): Cable Inner Bedding & Outer Cable Sheath APPROVAL DETAIL ATEX: SIRA06ATEX1283X, SIRA07ATEX4328X ATEX Code of Protection Category: ATEX Ex II 2/3 GD, Ex d...

Open the catalog to page 3
Cable glands and connectors - 4

CABLE GLANDS FOR HAZARDOUS AREAS E1FW Tri-Star Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland 05 Document Reference : TPC168 - Issue 1 - 11/08 CMP Type E1FW Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable. This cable gland provides a flameproof seal on the cable inner bedding and in addition the gas tight seal has been tested to prove compatibility with Restricted Breathing...

Open the catalog to page 4
Cable glands and connectors - 5

TERMINATING CABLES IS OUR BUSINESS E1FX Tri-Star Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland CMP Type E1FX Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) indoor and outdoor cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Braided, Pliable Wire Armour (PWA), Strip Armour and Steel Tape Armour (STA) cable. This cable gland provides a flameproof seal on the cable inner bedding and in addition the gas tight seal has been tested to prove compatibility with...

Open the catalog to page 5
Cable glands and connectors - 6

CABLE GLANDS FOR HAZARDOUS AREAS E1FU Tri-Star Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland 05 Document Reference : TPC168 - Issue 1 - 11/08 CMP Type E1FU Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) indoor and outdoor cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with all types of armoured cable. This cable gland provides a flameproof seal on the cable inner bedding and in addition the gas tight seal has been tested to prove compatibility with Restricted...

Open the catalog to page 6
Cable glands and connectors - 7

TERMINATING CABLES IS OUR BUSINESS PX2K Flameproof Ex d, Increased Safety Ex e, Restricted Breathing Ex nR Compound Barrier Cable Gland 05 TECHNICAL DATA TEMPERATURE RATING:-60°C to +100°C DELUGE PROTECTION: DTS01:91 CABLE TYPE: Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Wire Braid Armour (e.g. SWB), Screened Flexible Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Strip Armour (e.g. ASA) SEALING AREA(S): Inner Compound Barrier & Outer Sheath APPROVAL DETAIL ATEX: SIRA06ATEX1097X, SIRA07ATEX4326X ATEX Code of Protection Category: ATEX Ex II 2/3 GD,...

Open the catalog to page 7
Cable glands and connectors - 8

CABLE GLANDS FOR HAZARDOUS AREAS A2F Cable Gland, Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland 05 Document Reference : TPC168 - Issue 1 - 11/08 CMP Type A2F Triple Certified Flameproof (Type 'd'), Increased Safety (Type 'e') and Restricted Breathing (Type ‘nR’) indoor and outdoor cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with un-armoured and braided cable providing a combined flameproof seal and environmental seal on the cable outer sheath. This product provides full compatibility with restricted breathing equipment that...

Open the catalog to page 8
Cable glands and connectors - 9

TERMINATING CABLES IS OUR BUSINESS CMP V-TEC EX, EX L & EX M Cable Gland (A2Pe) Code of Protection EEx e II The CMP V-TEC Type EX, EX L & M Range (A2Pe) of Increased Safety (Type ‘e’) Non-Metallic Cable Glands for Unarmoured and Screened Flexible Cables, is endorsed by an EC design type approval certificate in accordance with the requirements of EN50014 : 1997 & EN50019 : 1994 and the ATEX Directive 94/9/EC, concerning safety of Electrical Equipment, Products and Protection Systems for use in potentially explosive atmospheres (Hazardous Areas). These Cable Gland products provide an...

Open the catalog to page 9
Cable glands and connectors - 10

CABLE GLANDS FOR HAZARDOUS AREAS CWe Increased Safety Ex e Cable Gland 05 Document Reference : TPC168 - Issue 1 - 11/08 CMP Type CWe Increased Safety (Type 'e') cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with Single Wire Armour (SWA) cable providing an environmental seal on the cable outer sheath. The cable gland being suitable for armoured cables, provides mechanical cable retention and electrical continuity via armour wire termination. A detachable armour cone and AnyWay universal clamping ring arrangement allows the cable to be easily disconnected from the...

Open the catalog to page 10
Cable glands and connectors - 11

TERMINATING CABLES IS OUR BUSINESS TMCX Hazardous Location Cable Connector 05 TMC Ordinary, Wet & Hazardous Location Cable Connector CMP Type TMC Cable Connector suitable for use with Corrugated Interlocked & Continuously Welded Metal Clad (Type MC or MC-HL) or TECK armored and armored & jacketed cables in ordinary, wet & hazardous locations including Class II Division 1 & 2 installations. TECHNICAL DATA TEMPERATURE RATING:-60°C to +130°C CABLE TYPE: Corrugated & Interlocked Metal Clad Armor (MC) or TECK, Continuously Welded Metal Clad Armor (MCHL) SEALING AREA(S): Cable Outer Jacket...

Open the catalog to page 11

All CMP Products catalogs and technical brochures

  1. E1FX/M

    1 Pages

  2. A2FHC

    1 Pages

  3. A2F/MF

    1 Pages

  4. A2F/M

    1 Pages

  5. A2F100

    1 Pages

  6. CMP TRITON

    6 Pages

  7. Rapid EX NEW

    12 Pages

Archived catalogs