A2 SOLO Cable Gland Kit
1Pages

{{requestButtons}}

Catalog excerpts

A2 SOLO Cable Gland Kit - 1

CMP SOLO - LOW SMOKE & FUME RANGE CMP PRODUCTS CABLE GLAND CATALOGUE TECHNICAL DATA Type Design Specification IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only POCC GB. Marine Approvals Ingress Protection Rating Deluge Protection Compliance Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer Cable Type Sealing Technique CMP Unique Displacement Seal Sealing Area(s) Cable Outer Sheath Cable Gland Kits Available • Designed to prevent Coldflow Enclosure Protection • Displacement type seal Impact = Level 8, Retention = Class D For all types of Unarmoured & Braid Armoured Cables Mechanical Classifications* A2 Industrial Single Seal Cable Gland SOLO LSF Kit Up to & including size 25 - 2 glands, 2 locknuts, 2 earth tags & 2 LSF shrouds Size 32 & above - 1 gland, 1 locknut, 1 earth tag & 1 LSF shroud • Deluge protected • -60˚C to +130˚C • LUL (London Underground) approved Note: Ordering suffix ‘2RA’ includes locknut, earth tag & shroud Other kit options available Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444 Note : ** Refer to page 7 or www.cmp-products.com for further information on Ingress Protection Ratings Gland Kit shown as example Cable Gland Selection Table Refer to illustration at the top of the page Cable Gland Size Metric Available Entry Threads “C” (Alternate Metric Thread Lengths Available) Standard Option Thread Thread Length NPT Length (NPT) NPT (Metric) “E” “E” 10.0 1/2” 19.9 3/4” Protrusion Length “F” (Without Shroud) Overall Cable Diameter “A” Min Combined Ordering Reference (*Brass Metric) Cable Gland Only Weight (Kgs) Ordering Suffix *For material options add the following suffix to the Ordering Reference; Brass (no suffix required); Nickel Plated Brass ‘5’; 316 Grade Stainless Steel ‘4’; Copper Free Aluminium ‘1’ For NPT options add the following digits to the material suffix; 1/2” = 31; 3/4” = 32; 1” = 33; 1 1/4” = 34; 1 1/2” = 35; 2” = 36; 2 1/2” = 37; 3” = 38; 3 1/2” = 39; 4” = 310 (Brass requires prefix ‘0’) Examples: 32A2LSF2RA534 = Nickel Plated Brass 1-1/4” NPT, 50SA2LSF2RA035 = Brass 1-1/2” NPT, 25A2LSF2RA432 = Stainless Steel 3/4” NP

Open the catalog to page 1

All CMP Products catalogs and technical brochures

  1. E1FX/M

    1 Pages

  2. A2FHC

    1 Pages

  3. A2F/MF

    1 Pages

  4. A2F/M

    1 Pages

  5. A2F100

    1 Pages

  6. CMP TRITON

    6 Pages

  7. Rapid EX NEW

    12 Pages

Archived catalogs