Handling Instructions
When handling the HD Howell Bunger Valve, ensure not to attach the crane directly to the valve actuator. Use the provided lifting lugs to avoid damage. Do not lift the valve by the valve bore to prevent damage to seating surfaces and sealings. Verify the crane's capacity to handle the valve's weight and ensure the valve is securely fastened.
Safety Warnings
Ensure personnel handling the valve are trained and equipped with appropriate personal protective equipment. Shut off all operating lines, isolate the valve from the process, release process pressure, and drain the valve before assembly or maintenance.
Assembly Instructions
Inspect the valve and components for damage before installation. Ensure the pipeline and mating flanges are clean and aligned correctly to prevent leakage and deformation. The valve is designed for one-direction flow, indicated by an arrow on the body.
Maintenance Instructions
Regular maintenance involves changing the sealing rubber joints located in the fixed and moving parts. Perform a sealing revision every six months, considering factors like pressure, temperature, and fluid composition. Use appropriate personal protection and follow lockout/tagout procedures.
Changing Sealing Joints
Fixed Part (Detail B): Open the valve completely, remove the bolts and steel flange, and replace the damaged EPDM sealing. Ensure the new sealing matches the old one in dimensions. Glue the ends of the sealing with high resistance glue before installation.
Between Fixed and Moving Part (Detail A): Close the valve completely, remove the bolts and steel flange, and replace the damaged EPDM sealing. Do not remove the Cestidur material. Ensure the new sealing matches the old one in dimensions and glue the ends before installation.
Additional Notes
Apply Vaseline (not oil or grease) to the sealing area during assembly for easier installation and smoother operation. Details of the Vaseline used include Saybolt colour ASTM D-156 15, Fusion point 60°C, Viscosity at 100°C 5, and no silicon content.
See more

Catalog excerpts

HD Series - Howell Bunger or Fixed Cone Valve-1

When handling this type of valves please pay attention to the following points: Do not attach the crane directly to the valve actuator. The valves are supplied with lifting lugs for that purpose and due to the valve weight the actuator could be easily damaged. Do not lift the valve by the valve bore. This can cause damages on the seating surfaces and sealings. SAFETY WARNING Check that the crane is rated to carry the weight of the valve. Make sure that the valve is correctly secured and fastened. During the assembling and dismounting it is recommended to lift the valve with soft straps. > To avoid personal injury or damage to the property from the release of process fluid: - Those in charge of handling and maintenance of the valve must be qualified and trained in valve operations. - User appropriate personal protection equipment (gloves, safety shoes, glasses, helmet). - Shut of all operating lines to the valve and place a warning sign. - Isolate the valve completely from the process. - Release process pressure. - Drain the process fluid from the valve. Before installation inspect the valve body and components for any damage that may have occurred during shipping or storage. Make sure the internal cavities within the valve body are clean. Inspect the pipeline and mating flanges making sure the pipe is free of foreign material and that the flanges are clean. As standard the valve is for one direction flow and there is an arrow on the body pointing to the flow direction. C.M.O. Amategui Aldea 142, 20400 Txarama-Tolosa (SPAIN) Phone: 943-67.33.99 / Fax: 943.67.24.40 / [email protected] http://www.cmo.es -1- >

 Open the catalog to page 1
HD Series - Howell Bunger or Fixed Cone Valve-2

The HD type valve (Howell Bunger) is always installed at the end of a pipe line. Special care need to the taken to keep the correct alignment and parallelism with the mating flange. The wrong situation of the mating flange can cause deformations in the body which can lead to difficulties in operation. It is very important to ensure plainness and parallelism of the mating flange to avoid a leakage to the outside and avoid deformations of the valve. > To avoid personal injury or damage to the property from the release of process fluid: - Those in charge of handling and maintenance of the valve...

 Open the catalog to page 2
HD Series - Howell Bunger or Fixed Cone Valve-3

CHANGING OF THE SEALING JOINT IN THE FIXED PART (DETAIL B) In order to change the valve sealing joint it is necessary to open the valve completely. The sealing is held to the valve fixed part by a steel bolted flange. The first step is to remove the bolts that are holding the steel flange to the valve fixed part. After that, remove the steel flange and also the damaged sealing in EPDM. Clean the channel where the sealing is located in the disc and change the old damaged sealing by a new one. Note: Keep in mind that the dimensions of the new sealing must exactly the same as in the old one. The...

 Open the catalog to page 3
HD Series - Howell Bunger or Fixed Cone Valve-4

Note: During the assembling of the new sealing joint it is recommended to apply VaselineӔ on the sealing area to make the assembling easier and to provide and smooth operation of the valve (do not use oil, neither grease). Following we are giving the details of the Vaseline used by CMO: VASELINE FILANTE Saybolt colour ASTM D-156 15 Fusion point (C) ASTM D-127 60 Viscosity at 100ںC ASTM D-445 5 Penetration 25C mm/10 ASTM D-937 165 Silicon Content No content Farmacopea BP OK CHANGING OF THE SEALING JOINT BETWEEN THE FIXED PART AND THE MOVING PART (DETAIL A) In order to change the valve sealing...

 Open the catalog to page 4
HD Series - Howell Bunger or Fixed Cone Valve-5

After cutting the sealing with the correct length, and before installation on the valve, both ends of the sealing must be glued together with high resistance glue (similar to Loctite brand). Note: It is very important to keep the stainless steel sliding surface correctly greased. After changing the sealing replace the steel holding flange to its original position and tight all the holding bolts. It is recommended to tight the holding bolts in a diametricalӔ way. Do not use sharpened tools during this process. Note: During the assembling of the new sealing joint it is recommended to apply VaselineӔ...