KRD14/15 PNEUMATIC SHOCK RESPONSE SPECTRUM TEST SYSTEM KRD14/15 Pneumatic Shock Response Spectrum Test System adopts compressed gas energy to provide shock energy. It is used to measure and determine the shock resistance of products or packaging, and to evaluate the reliability and structural integrity of the test product in a shock environment. The shock response spectrum is the total result of a series of single-degree-of-freedom linear systems with different natural frequencies subjected to the same shock excitation response. When a product is subjected to an impact, the maximum value of its impact response means that the product has a maximum stress. Therefore, the shock response spectrum tester can better simulate the shock wave and shock energy suffered in the real environment. Number of channels: 2~8 channels; The maximum acquisition frequency is 192kHz; Trigger mode: external trigger, level trigger, soft
Open the catalog to page 1System Features 1200mm table size withstand 1000kg load. Windows-based stable control system, full-automatic remote- The equipment takes up a small area and is easy to install. The control & measurement system has built-in SRS specifications and tolerances, which is convenient for users to adjust and apply. It automatically completes the test and generates reports. Adjust the driving shock energy by adjusting the air pressure, which is convenient to operate and high in efficiency. The system uses pneumatic energy storage to drive the impact hammer, with large driving force, fast response...
Open the catalog to page 2Table Layout Response Frequency Range (Hz): Response Frequency Range (Hz): Response Frequency Range (Hz): Gradient of Rising Stage (dB/Otc): 6~9 Gradient of Rising Stage (dB/Otc): 6~9 Gradient of Rising Stage (dB/Otc): 6~9 Specifications Common to All Models: Response Frequency Range (Hz): 10~10000 Gradient of Rising Stage (dB/Otc): 6~9 Tolerance Range (dB): ±6~9 Standards: MIL-STD-810; CE Compliance Power: Single-phase AC220V±10%, 50/60Hz Working Environment: Temperature range 0~40℃; Humidity≤80%, non-condense CME Technology Co., Ltd. Add.: No.3 Upgrade Demonstration Base, West of...
Open the catalog to page 3Technical Specifications Model Table Size(mm) Response Frequency Range (Hz) Max. Response Acceleration (g) Stage (dB/Otc) Tolerance Range Temperature range 0 ~ 40℃; Humidity ≤ 80%, non-condense Response Frequency Acceleration (g) Gradient of Rising Stage (dB/Otc) Tolerance Range Working Environment Temperature range 0 ~ 40℃; Humidity ≤ 80%, non-condense Note: The parameters in the/ table are for reference only, and the parameters agreed upon by the supplier and the buyer shall prevail. Add.: No.3 Upgrade Demonstration Base, West of Yo
Open the catalog to page 4