Cleveland-Kidder ® Ultra
4Pages

{{requestButtons}}

Catalog excerpts

Cleveland-Kidder ® Ultra - 1

Cleveland-Kidder ® Ultra ULTRA SLIM CELL TRANSDUCER LOAD CELL AMPLIFIER ULTRA L I N E Provides up to 40:1 Tension Range when used with one or two Ultra Line Load Cell Solutions. • Provides up to 40:1 tension range (Ex: accurately measures from 2.5 lbs to 100 lbs of tension when used with a 100 lb rated Ultra Line Load Cell). Performance Benefits Design Features Cleveland Motion Controls new Cleveland-Kidder® Ultra Line Load Cell Amplifiers operate over a wider tension range, accepting output from full bridge Ultra Line Load Cells (that provide a higher output signal for better signal resolution). They have the ability to measure lower (light) tensions, eliminating drift that can distort low-tension measurements, resulting in a substantial and stable output signal. They reject electrical noise with a four-wire differential technology, providing a common mode of rejection to electrical noise and disturbances––resulting in clean and accurate output signals devoid of distortion. Plus, with an advanced temperature compensation network that cancels out temperature influences, Ultra Line Load Cell Amplifiers produce a minimum amount of deviation of signal output, regardless of ambient temperature changes. The Ultra Line Load Cell Amplifier is designed to interface with a wide variety of controls for monitoring and measuring web tension. Two versions are available––the basic amplifier or an electrically-isolated amplifier. Analog outputs on both include 0 to +/- 10 VDC and 4-20 mA for use as a tension feedback signal or tension indicator (for use with with PCs, PLCs or other controls), 0-2 VDC with damping (for use with digital indicators) and a 0-1 mA signal with damping (for use with analog meters). It has a low power requirement, only 24 VDC power at 160 milli-amps. The analog outputs of the isolated module are galvanically isolated from the transducer load cell and power supply. This is a useful feature in systems where the tension signal is used for feedback, where ground loop or noise elimination is important. When used in conjunction with Ultra Line Load Cells, Ultra Line Load Cell Amplifiers provide better performance than competitive load cell amplifiers by increasing the operating tension range from 8:1 to 40:1. They also provide more accurate measurement by eliminating electrical disturbances caused by AC drives, servos, and other modern high frequency devices. The Ultra Line Load Cell Amplifier is low-profile, only 1.77 in. wide (45 mm), 4.14 in. deep (105 mm), and 2.95 in. high (75 mm). It weighs only 6.0 ounces (170 grams). The Ultra Line Amplifier is designed so that calibration adjustments and terminal strips are conveniently accessible from the front. Pluggable connections are removable for easy wiring. Essential specifications and a wiring schematic are located on the side, eliminating the need for a manual. www.ClevelandKidder.com • Rejects electrical noise from AC motors, servo motors, relay coils, as well as other electrical disturbances. • Operates over a wide tension range. • Specially designed to measure lower (light) tensions. • Easily maintains proper tension measurement regardless of changes in ambient temperature. • Easy to set up and calibrate. • Interfaces with a wide variety of controls for measuring and monitoring web tension.

Open the catalog to page 1
Cleveland-Kidder ® Ultra - 2

DIN-RAIL AMPLIFIER ULTRA SLIM CELL TRANSDUCER LOAD CELL Cleveland-Kidder ®Ultra AMPLIFIER Ultra Line Load Cells ULTRA L I N E Provides up to 40:1 Tension Range when used with one or two Ultra Line Load Cell Solutions. Ultra Line Amp 0 to +/- 10 VDC Output 4-20 mA 0-2 VDC Digital Meter 0-1 mA Analog Meter GENERAL AMPLIFIER SPECIFICATIONS Item Amplifier (Instrumentation) Number of Input Channels 4 Switch Selectable Gains Zero Range Nominal Input Signal Levels Ultra Amplifier Output Signals Ultra Amplifier Output Signals (Isolated Model) Specification 2, Fully Differential 8, 30, 150, 600 +/-...

Open the catalog to page 2
Cleveland-Kidder ® Ultra - 3

DIN-RAIL AMPLIFIER Cleveland-Kidder ®Ultra ULTRA SLIM CELL TRANSDUCER LOAD CELL AMPLIFIER ULTRA L I N E Item Specification Comments Load Cell (Transducer) Bridge Excitation Voltage 5.0 to 10.0 VDC @ 100mA Highly stable. Switch selectable. Shipped with excitation voltage set for 5.0 VDC. Load Cell Resistance Range Load Gage Type Physical Specifications Enclosure Type Enclosure Size Weight Terminals 100 to 1000 Ohms Semi-Conductor (1-100 mV/V) or Foil (2-3 mV/V) DIN-Rail mountable with user adjustments accessible from front surface. Snap-on cover to access factory adjustments. Base: 45 mm...

Open the catalog to page 3
Cleveland-Kidder ® Ultra - 4

DIN-RAIL AMPLIFIER ULTRA SLIM CELL TRANSDUCER LOAD CELL Cleveland-Kidder ®Ultra AMPLIFIER ULTRA L I N E WIRING DIAGRAM & ESSENTIAL SPECIFICATIONS For Easy Reference Labels Are Provided On The Side Of Each Ultra Line Load Cell Amplifier Essential Specifications--MWI-13262 Wiring Diagram Same For Ultra Basic and Ultra Isolated DIMENSIONS Part Number MWI-13262 Description Ultra Line Load Cell Amplifier (Basic) Height H 2.95” 75mm Width W 1.77” 45mm Depth D 4.14” 105mm Weight 6.0 oz 170g MWI-13261 Ultra Line Load Cell Amplifier (Isolated) 2.95” 1.77” 45mm 4.14” 105mm 6.2 oz 175g 75mm INDUSTRIAL...

Open the catalog to page 4