Classic UPB Transducer
4Pages

{{requestButtons}}

Catalog excerpts

Classic UPB Transducer - 1

UNDER PILLOW BLOCK WASHDOWN-DUTY LOAD CELL UPB Washdown-Duty LC Provides the ultimate solution for measuring and monitoring precise tension on web process or wire machinery in demanding industrial environments • For use with pillow block bearings and rotating shaft installations. • Washdown-duty, withstanding impinging liquids and wet environments. • Designed to comply with NEMA 4x, IP65/67 standards. Performance Benefits The UPB (Under-Pillow-Block) Washdown-Duty LC (load cell) is part of the Cleveland-Kidder® Tension Transducer product family. It sets the standard for under-pillow-block tension transducers for the web process industry. The UPB Washdown-Duty LC has a completely sealed corrosion-resisting design, making it ideal for use in demanding industrial environments, including the production of paper, steel, textiles, roofing shingles, linoleum, rubber, foil, and food products. The UPB Washdown-Duty LC can be mounted at any angle. Its web force direction is not restricted to being either parallel or perpendicular to the UPB top surface (common with other load cell designs). Its compact low profile design makes it perfect for use in both retrofit and OEM applications. The UPB Washdown-Duty LC is a solid one-piece design, providing a high natural frequency response with a high level, linear output signal. Design Features The Cleveland-Kidder UPB WashdownDuty LC is an under-pillow-block load cell that has been designed for measuring and monitoring tension on web process and wire machinery in demanding environments. The UPB Washdown-Duty LC is made from a solid block that results in a completely sealed design with a very low profile. It is typically applied in pairs, one under each of the supporting guide roll’s pillow block bearings. Mounting the pillow block bearing to the UPB Washdown-Duty LC is simple and convenient: Rather than having to drill into the top of the load cell, the UPB WashdownDuty LC uses a convenient mounting plate, making installation and replacement easier. Held in place by four corner bolts, the mounting plate is easily removed, drilled and tapped to match the pillow block mounting dimensions. The plate is then remounted and the pillow block bearing is bolted into place. To assure maximum corrosion and chemical resistance, the UPB Washdown-Duty LC is made from either Stainless Steel or Aluminum Alloy depending on the size rating. Displacement from loads is negligible (typically 0.002 in.) and the output is temperature compensated. • Completely sealed. Corrosionresisting and chemical-resisting (Stainless Steel 410 or Anodized Aluminum Alloy 6061). • Competitively priced against common non-sealed, non-corrosive and chemical resistive designs. • Compact low-profile design fits easily into tight places. • With an end connector design (instead of on the side), no need for a left hand and right hand configuration. • Available in a variety of load capacities (25 to 30,000 lb.) and sizes (6.5 to 17 inches long), suiting a wide range of applications. • Provides 500% overload protection. • Easily mounted at any angle. • Convenient mounting plate for easy installation of pillow block bearing. • Solid block one-piece design.

Open the catalog to page 1
Classic UPB Transducer - 2

UNDER PILLOW BLOCK WASHDOWN-DUTY LOAD CELL UPB Washdown-Duty LC Provides the ultimate solution for measuring and monitoring precise tension on web process or wire machinery in demanding industrial environments DIMENSION TABLES Size No. Maximum Working Force (lb.) Maximum Working Force (N)** *Allow 2.5 inches clearance (64mm) for connector. **Approximate rating in Newtons. INDUSTRIAL PRODUCTS 7550 Hub Parkway Cleveland, Oh 44125-5794 Tel: 216-524-8800 or (800) 321-8072 Fax: 216-642-2100 Visit Us: www.cmccontrols.com *Ultimate overload: Maximum force applied on the transducer without risking...

Open the catalog to page 2
Classic UPB Transducer - 3

UNDER PILLOW BLOCK WASHDOWN-DUTY LOAD CELL UPB Washdown-Duty LC SPECIFICATIONS Material: Gage Resistance: Procedure for Mounting the UPB Load Cell to the Machine Frame (see picture above) Remove the pillow block mounting plate (it is held in place by four stainless steel corner bolts) in order to gain access to the four load cell mounting holes. Drill and tap the machine frame to match the load cell mounting holes. Note: The UPB must be oriented so that the resultant tension force direction (bisector of the wrap angle) is in the same quadrant as the load direction arrow on the side of the...

Open the catalog to page 3
Classic UPB Transducer - 4

UNDER PILLOW BLOCK WASHDOWN-DUTY LOAD CELL UPB Washdown-Duty LC ORDERING PROCEDURE: 1. Calculate the Maximum Working Force (MWF) rating based upon your calculations from the sizing calculation equation. 2. From the Selection Chart, determine the part number for the UPB Washdown-Duty LC. Select a MWF rating that equals or exceeds the MWF from your sizing calculation. Then, make sure that your pillow block bearing fits the UPB type that you selected (UPB 1, 2, or 3). Example: If you calculate a MWF of 2,204 lbs., select a UPB 2 rated at 2,500 lbs. MWF from the Selection Chart. Your part...

Open the catalog to page 4

All Cleveland Motion Controls catalogs and technical brochures

  1. EMAG 260

    2 Pages

  2. EMAG 150

    2 Pages

  3. EMAG 90

    2 Pages

  4. EMAG 50

    2 Pages

  5. EMAG 9 Brake

    2 Pages

  6. EMAG 1

    2 Pages

  7. EMAG 4 Brake

    2 Pages